Unearthed Geotechnical P/L ABN 78 808 074 271 Wastewater Design Report O22-003 Lot 2 $P241381 Sister Tree Creek Road Kin Kin Noosa Council January 2022 For all geotechnical requirements Unearthed Geotechnical P/L mobile 0417 132 300 PO Box 1204. [email protected] Gympie Q 4570
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 30 pages
Page 2
1.00 INTRODUCTION In accordance with the relevant codes, standards and Noosa Councils guidelines, Unearthed Geotechnical P/L was commissioned to undertake a Site and Soil Evaluation at Lot 2 SP241381 Sister Tree Creek Road, Kin Kin. The results form the basis of our recommendations for the on-site treatment and disposal of wastewater from the four proposed one bedroom cabins on this 21.5 hectare rural allotment. A representative of Unearthed Geotechnical P/L was met and shown to the proposed site by the owner, J Williams. Our site investigation fieldwork was performed on 31/01/2022 after some recent seasonal storm/rain activity in the course of the preceding weeks. 1.1 Referenced Standards. Queensland Plumbing and Wastewater Code AS/NZS 1546:2012 On-site Domestic Wastewater Treatment Units AS/NZS 1547:2012 On-site Domestic Wastewater Management AS/NZS 3500 2:1996 Standard Sewerage Law Plumbing and Drainage Code AS 1319:1994 Safety Signs for the Occupational Environment AS 2698 .2:1990 Plastic Pipes Fittings for Irrigation Rural Applications 1.2 Report Limitations. Field Test Limitations The soil profiles detailed in this report should be representative of the soil conditions over this site. In some cases conditions can change dramatically over short distances. If site works reveal soil conditions that are different from those shown in the attached data, the evaluator must be informed immediately as changes may be necessary. Client Supplied Information we have considered the information supplied to us by the client. Should the client have omitted to supply us with relevant information or supplied us with incorrect information our assessment may be irrelevant and/or inappropriate. We do not take responsibility for the consequences in such cases and may incur additional costs if as a result; more testing or re-writing is necessary. 1.3 Copyright. The drawings, specifications and other documents provided by Unearthed Geotechnical P/L remain the property of the Unearthed Geotechnical P/L. Upon receipt of full payment for our service the client is licensed to use the drawings, specifications and other documents for the work/s for which they were commissioned. They shall not be used for any other work except by agreement with Unearthed Geotechnical P/L. Copyright in all the drawings, specifications and other documents remain the property of Unearthed Geotechnical P/L. Unearthed Geotechnical P/L. 1 Design Report 022-003
Page 3
2.0 SITE AND SOIL EVALUATION The field and officework undertaken for our site and soil evaluation consisted of i a desk top study in accordance with the regulatory authority a comprehensive assessment to record topography, geography and geology etc the confirmation of expected available areas and delineation of exclusion areas the assessment of site exposure and suitability a detailed subsoil investigation recording characteristics and limitations the determination of Soil Category, Colour, Texture, and Structure the determination of Indicative Drainage and Permeability soil observation boreholes (75-100 mm dia. Jarret style hand augers), the calculation of the Design Loading Rate (DLR) the collation and evaluation of the results from the above studies Be Boe Be Te Ge Ge Ge Be_ Go Ge (The test locations were not professionally surveyed and should be considered approximate) (All fieldwork performed in accordance with the relevant Australian Standards and Codes) (All boreholes backfilled in accordance with Occupational Health and Safety regulations) The purpose of this site and soil evaluation is to ensure that a suitable on-site sewage treatment plant/Land Application Facility is selected for this particular site. In compiling this report we have assessed the existing and historical parameters to gain a comprehensive overview of the potential for on-site domestic wastewater management. The scale of, and methodology of our site and soil evaluation is considered to be adequate, relative to, and indicative of the size of the facility, having considered the consistent natural soil profile and the availability of suitable land. Registered y Unearthed Gedt A full copy of this report and all the accompanying sketches plans details and notes shall be made available to all present and future owners and or occupiers of the proposed cabins that are to be serviced by this Land Application Facility, and to all contractors/suppliers/installers for quotation and or construction objectives. Unearthed Geotechnical P/L. 2 Design Report 022-003
Page 4
3.0 DESIGN DETERMINATION We have determined the soil to have the following characteristics Soil Characteristics (AS/NZS 1547-2012) Borehole Nos 5&6 Depth (mm) = 700 Soil Category 5 Indicative Drainage Poor Structure Strong Texture Light Clay Indicative Permeability P (m/day) as Ksa 0.12 - 0.5 For our calculations we have assessed the design flow as follows Design calculations Cabins 1 & 2 | Cabins 3 & 4 DLR (mm/day) (Advanced Enviro-septic™ effluent) 5-8 5-8 Hydraulic load (It/day/person) 120 120 Design flow Q (It/day) (equivalent population 4 people) 480 480 Total Trench/Bed Footprint (m’) 60 60 Septic Tank minimum size requirement (It) 3000 3000 Advanced Enviro-septic™ System Note — AS/NZS 1547-2012 (Appendix H, Table H1) lists the typical wastewater design flow allowance for households with an on-site roof water tank supply as 120It/person/day (all wastes). With the installation of standard water reduction fixtures the design flow can be reduced substantially. In this instance we have used the DLR rate of 8 mm/day due to the very strongly structured nature of the loamy Light Clay encountered. Where the design flow ‘Q’, nominated above, is exceeded the area (Ai) may need to be increased accordingly. This sewerage system is not suitable for accepting waste from garbage grinders. Unearthed Geotechnical P/L. 3 Design Report 022-003
Page 5
4.0 FINDINGS All the field information and test results collected during our site investigation and detailed in this report, including any site plans, log and data sheets together form the basis of our recommendations for this Land Application Facility. The soil profile encountered during our investigations, and as reported, was reasonably and acceptably consistent across the proposed development, and within our expectations from regional experience and correlation with The Qld Dept of Mines/Energy Geology Sheet 9445/1999 (Gympie). The Qld Dept Mines/Energy Geology Sheet 9445/1999 describes the geology as Early-Middle Triassic, Kin Kin Beds, arenite, argillite or phyllite. The proposed Land Application Areas are on an exposed 5-8% northern slope with neighbouring vegetation consisting of grasses. The landform was recorded as natural and partially disturbed. Slope configuration across the proposed site is determined to be linear planar. Slope stability problems were not evident during our investigations and expert evaluation deemed unnecessary. The susceptibility to flooding from groundwater is low and the indicative drainage was recorded as poor. No water table was encountered on the day of our site investigation. Cobbles and/or boulders in soil profiles are sometimes common and unfortunately we cannot predict their size or frequency. It has also been our experience that these floaters can be extremely difficult to excavate with conventional equipment. Unearthed Geotechnical P/L. 4 Design Report 022-003
Page 6
4.1 Limitations. Our site and soil evaluation noted the following limitations which may have an adverse effect on the performance, serviceability, and sustainability of environmentally acceptable on-site domestic wastewater management e allotment size, configuration and topographic idiosyncrasies, e — separation distance requirements, e areas previously used or required for construction or landscaping, e poor permeability of sub soil profile. In formulating our recommendations we have noted, considered and made allowance for the effect these limitations will have on the performance, serviceability, and sustainability of on-site domestic wastewater management. We consider that in line with the recommendations set out within this report, and with appropriate control measures in position, sustainable on-site domestic wastewater treatment and disposal will be achieved. In consideration of these limitations and with reference to the Queensland Plumbing and Wastewater Code and AS/NZS1547-2012 On-site Domestic Wastewater Management, we recommend advanced secondary treatment of all domestic wastewater flows for the efficient, sustainable and environmentally acceptable disposal of treated effluent on this allotment. The use of such approved advanced secondary treatment systems consequentially enables the 30m horizontal separation distance from the intermittent watercourses/dams to be reduced to 10m, and the vertical separation distance to be reduced to 300mm. Although we recorded no existing evidence of eutrification, we believe there is the potential for eutrification of any associated dam or watercourse if there is nutrient leakage from any disposal site. However, with our recommended, and appropriate vegetation planting, with the incorporation of a wastewater treatment system with nutrient stripping capabilities and with the encouraged use of phosphate free cleaning products, we believe the reduced potential will be contained. Unearthed Geotechnical P/L. 5 Design Report 022-003
Page 7
5.0 DESIGN RECOMMENDATIONS The four proposed cabins will utilize two identical wastewater facilities; Cabins 1 & 2 will be serviced by one facility, and Cabins 3 & 4 will be serviced by a second identical facility. We recommend the installation of two Advanced Enviro-septic™ domestic wastewater systems to treat the wastewater to advanced secondary quality. We recommend the installation of two 3000It (min capacity) all-waste septic tanks to treat the wastewater to primary quality (it should be noted that the local regulatory authority may have larger minimum size requirements than those recommended). The final location of the septic tanks will be determined on-site by variable consequences (e.g. finished floor levels, distances, allotment configuration and topographical constraints) over which we have little control. This final placement may necessitate the use of pumps and pump wells to enable the Land Application Area to be located above the septic tank. If the integrity and serviceability of the existing septic tank is confirmed it may be retained. Alternatively it may be decommissioned once the new septic tank is installed and commissioned. We recommend further consultation to determine the adequacy of the final location of the septic tanks and pump wells (if required) at the time of, or prior to construction of the proposed dwelling. Notwithstanding the final location of the septic tanks and the Land Application Areas particular attention should be paid to protecting any, or all pipework below driveways, access tracks, or such trafficable areas. The treated effluent is to be dosed into and along the Advanced Enviro-septic™ pipes. Thus receiving treated effluent and residuals in a manner and at a rate that enables their further treatment by natural in-soil stabilisation processes so that the resulting clarified carriage water is environmentally and hygienically acceptable for groundwater infiltration or evaporation and plant transpiration into the atmosphere. Pump systems (if required) shall e have a storage capacity equal to 50% of the daily flow allowance, and sufficient to match the electrical starting requirements of the irrigation pump motor e have performance characteristics that match the hydraulic characteristics of the irrigation system e have a discharge of at least 50% greater than the maximum 30-minute flow rate e have a visual and audible alarm system (with muting ability) for breakdown notification e not be located adjacent to bedrooms, living rooms or recreational areas of neighbouring properties e be contained in an acoustic chamber to reduce noise emission of all equipment to a level not exceeding 40 dB (measured as fast response at a distance of 1.0m), e have incorporated into the facility pressure and/or velocity reduction fittings installed sufficiently distant above the Advanced Enviro-septic™ piping. Unearthed Geotechnical P/L. 6 Design Report 022-003
Page 8
The installed systems will need capped 100mm diameter sampling ports accessible above ground to enable analysis or the performance of the system according to requirements in effect. The installed systems will need Oxygen Demand Vents, as per the Advanced Enviro- septic™ requirements. Oxygen Demand Vents ensure air is drawn completely through the Advanced Enviro-septic™ piping. Our recommendations do not preclude other or additional Land Application Facilities. Wastewater Treatment Systems and Land Application Facilities should be designed to remove as much nitrogen as possible by ammonification, settlement in sludge, denitrification, long residence times or plant uptake. Water conservation implementation will reduce the hydraulic load on the Land Application Facility and subsequently improve its performance and serviceable life. Effluent quality from the treatment plants must comply with the criteria presented in the Queensland Plumbing and Wastewater Code and AS/NZS 1547-2012 On-site Domestic Wastewater Management and be confirmed with the regulatory authority. Unearthed Geotechnical P/L. 7 Design Report 022-003
Page 9
5.1 Installation Notes. All installation works, components and fittings must comply with AS/NZS 1547- 2012 On-site Domestic Wastewater Management, and the Queensland Plumbing and Wastewater Code, and the local authority. All installation works, components and fittings must comply with Advanced Enviro- septic™ design & installation manual. The Advanced Enviro-septic™ pipes must be stored and installed adequately to prevent contamination of the fabric. Soils are susceptible to damage during the construction and installation processes. The natural integrity of the existing soil conditions of the Land Application Areas must be preserved at all stages of the proposed development. Damage to the existing soil profile must be avoided. The laying of the system sand and sand bed extension must occur immediately after excavation. The laying of the system sand and particularly the sand bed extension must be performed without compaction by wheeled vehicles or machinery. This facility must not be constructed or installed during or immediately after periods of wet weather and water must not be allowed to enter the excavation during construction. When excavating for the Advanced Enviro-septic™ pipes excavate in small bites using a bucket fitted with ripper teeth to preserve the permeability characteristics of the natural soil. Scarify/rake all smeared excavated surfaces. We recommend ripping the base of the entire excavation, along the contour and parallel to the lay of pipes, to a depth 200mm before backfilling with sand. We recommend the application of dolomite/gypsum at a nominal rate (say 0.5 kg/sqm) when preparing the existing soil. This will assist with both plant growth and pH control (further applications may be required during the serviceable life of the Land Application Areas). Particular care should be taken with the layout and construction of supply line trenching/pipework, as with all drainage, plumbing and electrical trenches to inhibit surface water infiltration along and into the Land Application Areas. If necessary all supply line excavations and trenching shall be backfilled with interceptors. Particular care should also be taken with the layout and construction of the Land Application Area trenching/pipework so that released effluent cannot travel back along trenching causing excessive soil moisture in some areas. As with all effluent disposal in Land Application Areas, the release of effluent along the contours (i.e. level) is both elementary and critical to achieve efficient spread and even disposal. The trenches/beds must be constructed level. Unearthed Geotechnical P/L. 8 Design Report 022-003
Page 10
Correct pipe layout and Land Application Area construction/installation is an essential part of our recommendations and design. If the site is not prepared in accordance with our design, or is prepared inadequately or is prepared poorly, inefficiencies may occur and we do not take responsibility for the consequences in such cases and we will make an additional charge if as a result, more testing, re-designing or re-writing of the report is necessary. Noosa Council may require an inspection for certification to be carried out before final approval can be issued. Unearthed Geotechnical P/L recommends an inspection for certification be carried out by the designer prior to commissioning, and preferably during construction, to ensure code compliance and that ‘best practice’ principles have been utilised. As with all use of sand or distribution aggregate for wastewater treatment and disposal it is very important to restrict the ingress of finer particles to maintain the integrity of the expected performance outcomes of the sand or distribution aggregate. To this end Unearthed Geotechnical P/L suggests the entire bed of sand or distribution aggregate be covered in an appropriate and approved geotextile fabric to restrict such ingress of finer soil particles. This will help to maintain the expected performance outcomes of the sand or distribution aggregate. Without the use of an appropriate and approved geotextile fabric it is probable that the integrity of the sand or distribution aggregate will likely be compromised. The treatment plant/ tanks traps and associated fittings shall be e constructed of durable materials with expandable and/or flexible connections, e positioned correctly in relation to boundaries, buildings etc to provide an angle of repose of at least 45 degrees between the bottom of the footing system/excavation and the base of any associated excavation e watertight and capable of withstanding loads imposed on the roof and walls e installed so that flotation will not occur when the tank/s is empty e — installed on a stable base and to prevent surface water infiltration. e located with good clear access for servicing and desludging operations e located within a designated area to enhance its amenity e be protected from roof water/tank discharge, surface water flow and/or seepage e installed and operated in accordance with regulatory guidelines. The supply lines to the septic tank must be adequately vented with mosquito proof cowls fitted to all vents. The Land Application Areas shall e not be located on land prone to water logging or subject to floodwater inundation e be sited to be open to prevailing winds and not totally shaded from sunlight e — be protected from roof water discharge, surface water flow and/or seepage e have no runoff or seepage of the applied effluent beyond the designated area e be regularly inspected and maintained e have the mandatory signage prominently displayed e have boundaries (fence) to deter grazing animals and casual pedestrian traffic Unearthed Geotechnical P/L. 9 Design Report 022-003
Page 11
As the slope configuration was recorded to be linear planar the Land Application Areas shall be protected from surface water infiltration by the installation of an excavated surface water diversion drain (suggested minimum 1000mm wide and 150mm deep) and from runoff by the installation of a vegetated track rolled retention mound/transpiration buffer zone (suggested minimum 1000mm wide and 150mm high). In this instance the drainage characteristics of the consistent soil profile, and the topographical location of the proposed Land Application Areas (i.e. adjacent to, and downslope of the well-formed pad) may be deemed to offer some, or sufficient protection from surface water infiltration. ‘Similarly, the existing endemic vegetation, extending more than 30 m downslope of the proposed Land Application Areas may be deemed to be satisfactory as the recommended transpiration buffer zone. It is essential that all associated stormwater flows from this and neighbouring allotments, driveways, roads, tanks and roofs are diverted away and well clear of the proposed Land Application Areas by proper final grade of the finished surface. We recommend the base of the entire excavations and the existing ground immediately downslope of the AES trench (approximately 1m) shall be ripped, along the contour and parallel to the lay of pipes, to a depth of 200mm prior to the construction of the AES installation, whilst adding dolomite/gypsum at nominal rate (say 0.5 kg/sqm). During the excavation processes we recommend separation of the brown topsoil (to be spread over the top of the entire installation to facilitate grass growth) from the orange/red/brown subsoil which is used to backfill the sand bed. We further recommend a minimum depth of cover at the low side of the sand bed extension of 300mm. Unearthed Geotechnical P/L. 10 Design Report 022-003
Page 12
5.2 Planting Regime. Plantings improve the efficiency of the system with the uptake of nutrient and natural transpiration processes. Further qualified advice from local nurserymen and the local regulatory authority should be preferred when choosing plants that may be more or less suitable or acceptable to your region. Grasses should be kept well mown and raked for better evaporative and transpiration processes (avoid throwing grass clippings onto the Land Application Areas). Shrubs should be kept well pruned for better evaporative and transpiration processes. Endemic vegetation must be retained and/or reinstated. Following the site preparation, installation and pre-commissioning tests the Land Application Areas shall be allowed to revegetate with sufficient appropriate shallow rooting grasses as determined by historical performance outcomes. Unearthed Geotechnical P/L recommends further assessment regarding planting requirements be sought prior to, or at the time of installation of the Land Application Facilities. It may be necessary to implement an additional planting regime. Do not plant shrubs or trees within the surface water diversion drains, as these drains need to be kept free of obstruction and trash for maximum diversion efficiency. We recommend the application of dolomite/gypsum at a nominal rate (say 0.5 kg/sqm) to the entire basal areas, when preparing the existing soil. This will assist with both plant growth and/or pH control. Further applications may be required during the serviceable life of the Land Application Areas. Unearthed Geotechnical P/L. 11 Design Report 022-003
Page 13
5.3. Separation Distance Requirements. One of the most important parameters to consider in the location of Land Application Areas is the separation distances, both vertical and horizontal. Poorly or inappropriately selected ground may contribute to the pollution of surface water and groundwater, ponding and eutrification. Surface Horizontal Separation distance requirements Feature Primary Secondary a. Sm Permanent watercourses (lake/stream/river) 50m 30m 10m Intermittent watercourses (dams/channels/weirs) 50m 30m 10m Bore (human and or domestic consumption) 50m 30m 10m EMT boundary unlined/open stormwater drainage 50m 30m 10m Property boundaries/paths/walkways 4m downslope 2 m upslope boundary Dwellings/play areas 15m 10m spray 10m spray 4m sub/cvrd | 4 m sub/cvrd Swimming pool (water edge) 6m 6m 6m Inground watertank 15m 6m 6m Vertical Separation distance requirements ‘ ‘ Advanced Depth of unsaturated soil to Primary | Secondary Secondary Permanent watertable 1.2m 0.6m 0.3m Bedrock/hardpan 1.2m 0.6m 0.3m 5.4 Effluent Quality. Effluent quality requirements must be confirmed with the relevant local council before proceeding and when tested shall comply with the following; Effluent Quality Primary | Secondary = dara Biochemical Oxygen Demand (mg/litre) 120-240 <20 <10 Total Suspended Solids (mg/litre) 65-180 <30 <10 Total Nitrogen (mg/litre) 36-45 <30 Total Phosphorous (mg/litre) 6-10 <10 Thermotolerant Coliforms (organisms/100mL) <200 <10 Unearthed Geotechnical P/L. 12 Design Report 022-003
Page 14
6.0 DEFINITIONS Advanced Secondary treatment system - These systems treat domestic wastewater to 10 mg/L BOD; 10 mg/L TSS standard or better prior to discharge to the land application area. Biochemical oxygen demand (BOD) - A measure of the amount of oxygen used in the biochemical oxidation of organic matter, over a given time and at a given temperature; it is determined entirely by the availability of the material as a biological food and by the amount of oxygen used by the microorganisms during oxidation. Blackwater — Wastes discharged from the human body either directly to a composting toilet or through a water closet (flush toilet) and/or urinal and the water used for the discharge. BODs- BOD determined by standard test (5 days at 20°C). Design Loading Rate (DLR) — The loading rate secondary or advanced secondary effluent can be applied to the soil of a disposal system expressed in mm/week Effluent — Sewerage, water or other liquid partially or completely treated or in its natural state flowing out of a septic tack, aerated wastewater treatment system, sand filter or other treatment system or treatment component. Expected available area — Areas, which at the time of evaluation have no physical constraints to inhibit the design, instillation, operation and maintenance of disposal. Greywater — The domestic wastes from a bath, shower, basin, laundry and kitchen but excluding toilet and urinal wastes. Intermittent watercourse — A natural or artificial stream or channel, identifiable by recognisable bed and banks, along which rainwater or storm water usually or occasionally flows. Land application area — The area over which the treated effluent is evenly applied. Land application facility/system —Is a facility for treatment, re-use or sustainable disposal of effluent from a treatment plant on land under controlled conditions. On-site sewerage treatment plant — Includes septic tanks, aerated wastewater treatment plants, sand filters, wet composting toilets etc. Permeability — (P - m/day) calculated value derived from the rate at which a head of liquid is absorbed into a soil. Primary treatment system - These systems treat domestic wastewaters to 120-240 mg/L BODs, 65-180 mg/L TSS standard or better prior to discharge to the land application area. Reserve Area — an area set aside for future use as a Land Application Facility to replace or extend the original system. Secondary treatment system - These systems treat domestic wastewater to 20 mg/L BODs, 300 mg/L TSS standard or better prior to discharge to the land application area. Sewerage - The wastewaters from the community, including all faecal matter, urine, household and commercial wastewaters that contain human waste. Surface Horizontal Setback Distances — Separation distances from watercourses, dams, drainage channels, bores, wells, boundaries, paths, dwellings etc. Total suspended solids (TSS) - The portion of total solids retained on a glass fibre filter with a nominal pore size 2 microns, measured after being dried at a 103-105°C. Vertical Setback Distances — Separation distances from permanent watertable or bedrock. Wastewater — The spent or used water from human or household or commercial and institutional activity that contains dissolved or suspended matter (sewage). Unearthed Geotechnical P/L. 13 Design Report 022-003
Page 15
OPERATION AND MAINTENANCE GUIDELINES General. The purpose of these guidelines is to provide guidance to homeowners and operators on maintaining a Land Application Facility in an unsewered area. The focus of these guidelines is the facilitation of sustainable on-site disposal of treated effluent without compromising public health or the quality of the environment. The amount of wastewater to be treated is a major design factor in wastewater treatment systems. Exceeding the design flow will contribute to failure. Water conservation will reduce the volume of effluent requiring disposal to the Land Application Area, which will increase its serviceable life and improve its efficiency. Conservation measures include e employing careful water use habits, installation of water conservation fittings, installing low-flush toilets where appropriate, taking showers instead of baths, installing small/efficient shower roses, purchasing washing machines with economy water cycles, having leaking taps repaired immediately, only using the dishwasher when there is a full load, only washing clothes when there is a full load, and avoid overloading the system by spacing out water use as evenly as possible. AS/NZS 1547-2012 (Appendix H, Table H1) lists the typical wastewater design flow allowance for households with an on-site roof water tank supply as 120-lt/person/day (all wastes). With the installation of standard water reduction fixtures the design flow can be reduced substantially. Efficient on-site sewerage treatment relies on a balanced combination of physical, biological (bacterial) and chemical processes. In order to keep the bacteria working efficiently in the tank and in the land-application area: e use biodegradable soaps and low-phosphorus detergents, use biodegradable cleaning products with low phosphorus and nitrogen levels, use low-sodium detergent in dispersive soil areas, use detergents in recommended quantities, do not use powerful bleaches, whiteners, soakers, spot removers and disinfectants, do not put chemicals, chlorine, water softeners or paint down the drain, and do not put vegetables, meats, fats, oils coffee, citrus, cigarettes or medicines down the drain. Unearthed Geotechnical P/L. 14 Design Report 022-003
Page 16
All wastewater treatment plants/systems work less efficiently when overloaded with solid wastes. All reasonable and necessary actions and efforts to restrict the flow of solid wastes, particularly from the kitchen, shall be encouraged and employed by all present and future owners/ occupiers/users of this Land Application Facility. A primary wastewater treatment tank (septic tank) e will need to meet all design, standards and local government requirements, e will need to be desludged regularly, e may need a baffled/wiered distribution box set level on 0.9 x 0.9 x 0.1m concrete to evenly distribute the effluent into the trenches/beds, if and as required by the design. Garbage grinders are not to be installed on an Advanced Enviro-septic System as their use introduces additional solid matter, which must be broken down by the bacteria. Their use also greatly increases the hydraulic load entering the system. The choice of cleaning products will influence the environmental impact of greywater and, equally, will influence the overall performance of treatment within the septic tank. Only genuine biodegradable products and products with low phosphorus should be used. Common washing powders contain sodium salts as bulking agents which produces a saline greywater. Powdered products which use potassium salts or liquid concentrates produce better quality greywater. Some detergents and powder cleansers contain boron which not only can be toxic to plants in high concentrations but can also be toxic to animals. Operation. This Land Application Facility shall be used only for effluent application and not used for purposes that compromise the effectiveness of the system or access for future maintenance purposes. In order to reduce sludge build-up in the tank and pipework do not dispose of used cooking oil grease/fats or food scraps or similar material down the sink. Do not allow newspapers, disposable or sanitary napkins, rubber products, nappy liners, cotton buds etc. to enter the system. The use of better quality toilet paper can also help in improving operation of the system. Do not allow excessive quantities of disinfectant liquids, bactericides, antiseptics, strong caustics, acids, alkalis or chemical detergents to enter the wastewater system. Their use can severely affect the bacterial, biological and chemical processes within the system. Minimise their use and use more environmentally friendly products. Where possible, the owners/householders/users should avoid shock loading of the system, for example, by staggering the hours that the washing machine is used, and the peak times in the bathroom. Washing machines should be used where possible throughout the week instead of several loads within one day. Unearthed Geotechnical P/L. 15 Design Report 022-003
Page 17
Maintenance. The plants and grasses used in conjunction with any Land Application Area should be kept well pruned, mowed and raked to ensure that these plantings take up nutrients with maximum efficiency. Grass cuttings should not be allowed to accumulate over the Land Application Area. Septic tanks reduce solids by bacterial deposition. Consequently, sludge settles at the bottom of the tank and a scum or crust forms at the liquid surface. Periodic checks are necessary (eg annually depending on the load entering the system), to ensure that no carry-over of sludge (or crust) is entering the trenching (disposal system), thereby inhibiting its usefulness. If the sludge depth in the bottom of the tank is 300mm or less from the bottom of the outlet, then it is time to have the septic tank desludged (i.e. emptied). It may well be a number of years before the sludge level rises to a level (when scum and sludge occupy 2/3rds the volume of the tank or fist stage of a two- stage system), which is detrimental. This is seldom less than three (3) years (depending of course on the load entering the system). Under normal circumstances, desludging of a septic tank should be performed every three to five (3-5) years. If existing septic tanks are to be incorporated they shall be fitted with outlet filters, and must also be pumped out before commissioning of the system. The grease interceptor trap (if fitted) must also be cleaned out on a regular basis or as required — dependent upon the load. All manufacturer maintenance/service requirements are to be met. Unearthed Geotechnical P/L. 16 Design Report 022-003
Page 18
Planting Regime. Plantings improve the efficiency of the system with the uptake of nutrient and natural transpiration processes. Further qualified advice from local nurserymen and the local regulatory authority should be preferred when choosing plants that may be more or less suitable or acceptable to your region. Grasses should be kept well mown and raked for better evaporative and transpiration processes (avoid throwing grass clippings onto the Land Application Areas). Shrubs should be kept well pruned for better evaporative and transpiration processes. Endemic vegetation must be retained and/or reinstated. The Land Application Areas shall remain vegetated with sufficient appropriate shallow rooting grasses, and the retention mound/transpiration buffer zone shall also remain vegetated with sufficient appropriate shallow rooting grasses, shrubs or small trees as determined by historical performance outcomes. Unearthed Geotechnical P/L recommends further assessment regarding planting requirements of the Land Application Areas throughout their serviceable life. It may be necessary to implement an additional planting regime. Do not plant shrubs or trees within the surface water diversion drains, as these drains need to be kept free of obstruction and trash for maximum diversion efficiency. We recommend the occasional application of /gypsum at a nominal rate (say 0.5 kg/sqm) to the Land Application Areas throughout their serviceable life. This will assist with both plant growth and/or pH control. Further applications may be required during the serviceable life of the Land Application Areas. Unearthed Geotechnical P/L. 17 Design Report 022-003
Page 19
Greywater Characteristics. The definition of greywater in the AS/NZS 1547:2012 Onsite Domestic-wastewater Management is: “The domestic wastes from a bath, shower, basin, laundry and kitchen but excluding toilet and urinal waste”. The characteristics of greywater generated by a household will vary also according to the dynamics of the household and is again influenced by the number of occupants, the age distribution of the occupants, their lifestyle characteristics and water usage patterns. Wastewater may have become contaminated in three ways ¢ by microorganisms, many of which may be pathogenic, i.e. cause disease; e chemically by dissolved salts such as sodium, nitrogen, phosphates and chloride or by organic chemicals such as oils, fats, milk, soap and detergents which may provide food for micro-organisms and plant growth; and e physically polluted by particles of dirt, food, lint and sand etc. Greywater contains many impurities, including nutrients such as nitrogen and phosphorus, which may harm the environment and the soil in particular. There are some chemicals, which are not capable of being treated or degraded in the soil. Therefore the soil ecosystem must be capable of adsorbing, absorbing, assimilating or treating the chemical impurities and nutrients without medium and long-term degradation of the soil of the environment. Domestic greywater treatment systems are designed primarily to treat organic matter and are not normally designed to remove chemical salts such as sodium, nitrates and phosphates that may be found in greywater. If a member of the house is ill or is carrying a subclinical infection, greywater may carry infectious bacteria or viruses. However, in order for the greywater to make another person ill it would be necessary for that person to drink or otherwise consume the contaminated greywater inhale aerosols, touch or consume items, which have come in contact with contaminated water. The objectives of the standards are to avoid human contact with greywater. When greywater is being used follow these rules: e don’t drink or play in greywater. e don’t allow anything that may be eaten to come in contact with greywater. e don’t allow greywater to pond on the surface or run off the property. ¢ don’t wash domestic pets in greywater or allow these pets to drink the greywater. ¢ wash your hands after contacting greywater or otherwise dealing with greywater. Storage of Greywater. All forms of wastewater when stored will turn septic unless the wastewater is treated to a high standard. Similarly, when greywater is stored it will also turn septic giving rise to offensive odours and provide conditions for microorganisms to multiply. Significant levels of pathogens have been found in stored greywater after eight days. Should the stored septic greywater be surface irrigated it will give rise to extremely offensive odours, provide conditions conducive to disease transmission and attract insect and rodent vectors. Greywater must not be stored, other than temporarily, unless adequately treated. Unearthed Geotechnical P/L. 18 Design Report 022-003
Page 20
Presence of Pathogenic Microorganisms. Greywater may be contaminated with microorganisms such as bacteria, viruses and protozoa. It is these microorganisms, many of which may cause disease, that present the greatest health concern associated with greywater recycling and disposal. While many bacteria cannot survive in a hostile environment like soil, some bacteria and viruses that cause disease are resilient and can often survive for long periods of time in this environment. Disease transmission is principally through the faecal-oral route where the greywater may be directly ingested through contaminated hands or indirectly ingested through contact with contaminated items such as grass, soil, toys, garden implements and treatment plants while they are being serviced. Transmission may also occur through inhalation of irrigated spray, by penetration through broken skin, and by insect vectors such as flies and cockroaches. Contaminated drinking water aquifers may facilitate ingestion of pathogens. Comparison with Raw Sewage and Blackwater. Raw sewage, blackwater and septic tank effluent are all forms of effluent that are directly and grossly contaminated with human excrement and therefore represent a public health threat. Sewage, blackwater and septic tank effluent are all managed by a high level treatment before being released into the environment above ground level and must at least be settled or filtered to remove solid particles before management by sub-soil land application area. Raw sewage is usually directed, in metropolitan and urban areas, to a centralised sewage treatment plant for treatment and utilisation or disposal. Septic tank effluent is sewage that has been stored in a large vessel or tank and has turned septic, i.e. all the oxygen in solution has been consumed by the decaying process and the septic tank effluent becomes offensively smelly. Laundry Greywater. Microbiological: variable thermotolerant coliform loads, depending on dwelling occupancy i.e. family with children. Wash water has poorer microbial quality than rinse water. Chemical: sodium, phosphate, boron, surfactants, ammonia and nitrogen from soap powders and soiled clothes. Physical: high in suspended solids, lint and turbidity. Biological: high in biochemical oxygen demand, Laundry wastewater represents about 23% of household wastewater (35% of greywater). The detergents used in clothes washing give rise to the presence of phosphorus, ammonia, organic nitrogen and boron in varying amounts depending on the product and suspended solids such as lint, hair and dirt. Many of these contaminants are classified as nutrients and if transferred to waterways or groundwater may lead to environmental damage. Unearthed Geotechnical P/L. 19 Design Report 022-003
Page 21
Bathroom Greywater. Microbiological: variable levels of thermotolerant coliform, poorer microbial quality than laundry rinse water. Chemical: soap, shampoo, hair dyes, toothpaste and cleaning chemicals. Physical: high in suspended solids, hair and turbidity. Biological: \ower levels of concentrations of biochemical oxygen demand. The bathroom (hand basin, shower and bath) generates about 38% of the household wastewater flow (55% of greywater) and is considered to be the least contaminated type of greywater. Wastewater from hand basins is more polluted than bath or shower wastewater. Soap is the most common chemical contaminant found in bathroom greywater and other common contaminants are hair shampoo, hair dyes, toothpastes and cleaning chemicals. Biocidal soaps have little effect on reducing the bacterial load in greywater. Kitchen Greywater. Microbiological: variable thermotolerant coliform loads. Chemical: detergents, cleaning agents. Physical: food particles, oils, fats, grease turbidity. Biological: high in biochemical oxygen demand. Kitchen wastewater is heavily polluted physically with food particles, oils, fats and other highly polluting waste and is often more polluted than blackwater or raw sewerage. It readily promotes and supports the growth of microorganisms. Because of the solid food particles and because fats can solidify, kitchen wastewater may cause blockages in land application systems unless fats are treated or removed from greywater. Swimming Pool and Spa Pool Backwash Water. Swimming pool backwash water is highly concentrated in microorganisms, chemicals (such as body oils and cosmetics) and particulates such as powder residue, hair, lint and pool chemical residues. The amount of backwash water is difficult to estimate and is variable depending on the size of the pool, filter type and usage patterns. Unearthed Geotechnical P/L. 20 Design Report 022-003
Page 22
INFECTIOUS AGENTS PRESENT IN RAW DOMESTIC WASTEWATER Organism Disease | Remarks Bacteria Escherichia coli Gastroenteritis Diarrhoea (enteropathogenic) Legionella pneumophila Legionellosis Acute respiratory illness Leptospira (150 spp.) Leptospirosis Jaundice and fever (Weil’s disease) Salmonella typhi Typhoid fever High fever, diarrhoea and ulceration of small intestine Salmonella (~1700 spp.) Salmonellosis Food poisoning Shigella (4 spp.) Shigellosis Bacillary dysentery Vibrio cholerae Cholera Extremely heavy diarrhoea and dehydration Yersinia enterolitica Yersinosis Diarrhoea Viruses Adenovirus (31 types) Respiratory disease Enteroviruses (67 types eg. Polio, echo and Coxsackie Gastroenteritis, heart anomalies and meningitis viruses) Hepatitis A Infectious hepatitis Jaundice and fever Norwalk agent Gastroenteritis Vomiting Reovirus Gastroenteritis Rotavirus Gastroenteritis Protozoa Balantidium coli Balantidiasis Diarrhoea and dysentery Cryptosporidium Cryptosporidiosis Diarrhoea Entamoeba histolytica Amebiasis (amoebic Prolonged diarrhoea with dysentery) bleeding and abscesses of the liver and small intestine Giardia Lamblia Giardiasis Mild to sever diarrhoea, nausea and indigestion Helminths Ascaris lumbricoides Ascariasis Roundworm infestation Enterobius vericularis Enterobiasis Pinworm Fasciola hepatica Fascioliasis Sheep liver fluke Hymenolepis nana Hymenolepiasis Dwarf tapeworm Taenia saginata Taeniasis Beef tapeworm Taenia solium Taeniasis Pork tapeworm Trichuris trichiura Trichuriasis Whipworm Source: Metcalf and Eddy, Inc., 1991. Unearthed Geotechnical P/L. 21 Design Report 022-003
Page 23
Conclusion. A failed Land Application Facility is both a serious public health risk and an environmental hazard that can lead to the spread of infectious diseases, breeding mosquitoes and attraction of flies and rodents, nuisance and unpleasantness, pollution and infection of waterways, contamination of bores, wells and groundwater, alteration of the local ecology, fish kills, and legal action. Problems can occur with systems that have not been adequately maintained. Some early warning signs are very obvious the disposal area is wet and/ or soggy with effluent ponding on the surface, there is a smell of “sewerage” near the septic tank or absorption area, the drains and toilets run slowly, the grease trap is full or blocked, mechanical failure, and excessive running costs. Home owner/occupiers/users are legally responsible to keep their on-site wastewater treatment system in good working order. If any warning signs are evident the home owner/occupier/user must contact the nearest local authority office without delay. A full copy of this report and all the accompanying sketches plans details and notes shall be made available to all present and future owners and or occupiers of the proposed cabins that are to be serviced by these Land Application Facilities. Unearthed Geotechnical P/L. 22 Design Report 022-003
Page 24
2202/10/1E "NV" WO9'SdL@GSHLYVANN “0487 D AIdWAD “7021 XO Od ISZO07ZD980 “Wd IWO9INHDSLOAD GaHLYVANN £00-220 “ON 434 "A,GE,1G02SI S.LE,7109Z Sd 9/SILVNIGHO-OD TIINNOD VSOON ‘NIM NI ‘GVOY Wa3YD 3IaL YALSIS [eCl7ZdS Z 107 NOIL VIO T/SSIdGgy ‘Sdag NIM NI¥ ‘DISSVIL JIddIW-ATHVZ - GaWYISNOD ‘6661/S776 LASHS 4901039 ADYANS/SANIW Ldag a71O 4907099 ylv dXJ 1VI07 TWUNLVN GagNLsiq ATIVILYVd NO/LIGNOD FIVIINS “ATAVIIVAV WOI< SYIVELIS YNVL ATddNS HILVM WH 009 = HLdIg 0S Ma SITdG0D YWNVId YVANIT W404 alv4 SSIIIV W2< FTAVL YILVM SASSVU9 93) | VH 62G'1Z 3ZIS LOT NadQ 8N LIS %8-S 3d07S waau9 NIY NIY JOVNIVEG YX” M204 GAYaHLVAM ATALVYSCOW ONIHDVOUddY a/o ¢ aa a/W S°0-2Z1'0 3NIJ 9 Mad | S OSNONLS = AVID LHOIT, Yg@4oOaYy = LSIOW q o00l< zZ 9 Mo7 a/W G‘I-S'0 aNIJ 9 Ma4 4 HOIH WVO7] AV19 yg LSIOW Vv 00! | MO0Y GSYSHLVAM ATaLVYSGOW ONIHDVOddy a/d ¢ aa a/W G'0-21'0 aNi4 may g DNOMLS = AVID LHOIT, YG 4oaYy = LSIOW q 000l< zZ S MO7 a/W S'I-S'0 3NI4 M34 4 HOIH WVO7 AV19 ug Lsiow v 001 | ALIDILSWId | ALIMISVAWYAd | SLNSWOVY ASYVOD = ANOOSLVD — FaNLONALS — -AYNLXAL 40109 = FUNLSIOW =NOZIMOH = Hdd = AV]
Page 25
ADVANCED
ENVIRO-SEPTIC Advanced Enviro-septic Design Calculator V8.8
“Always The First Option”
LPT OW ghey LLL
Sit
Adis 330 (LOT 2 S$P241381] SISTER TREE CREEK ROAD, KIN KIN CABINS | & 2 State QLD Post Code 4571
Client
Name Yee N de iS Date of Site Visit 31/02/2022
igners Ph i
Designers 4 | TRELOAR, UNEARTHED GEOTECHNICAL P/L Desianes, 0417 132 300 Number 9BCC740251
Name Number
Plumber Ph Plumb / Drainer
oe Number Lic Number
Council Designers AES
pram NOOSA Cert Number Date 2/2/2022
other site constraints addressed by the qu
ified desiga
sification, surface water, water tables an
‘This Calculator is a guide only, receiving soil
Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 [>> This design is for an ADVANCED ‘ONDARY system
Is this a new installation Y or N y >> Minimun single vent size is 80mm or 2 x 50mm house vents
Number of person 4 a septic tank outlet filter is NOT RECOMMENDED
Daily Design Flow Allowance Litre/Person/Day 120
Number of rows required to suit site constrants 2 >>The maximum length of a single AES pipe run is 30 meters
Infiltration surface Soil Cat as est by site/soil evaluation. CATEGORY 5 >> Catagory may require design considerations. Ref AS 1547
Design Loading Rate based on site & soil DLR (mnvday) 8 >> Soil condi may be ry. Ref ASIS47 & C
Bore log depth below system Basel area 600__|>>Min depth below basel area 600mm check water table/restrictive laye
AES FOOTPRINT MUST BE LEVEL WITH TRENCH EXTENSION 1 >>Consideration reqd for Sloping sites. Ref AS1547. refer comment.
Is this design a gravity system with no outlet filter? Y or N ¥ >> A House Vent & LOW VENT required on this system
PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES
COMMENTS :-" The ontcome must be important to everyone."
- Ripping of receiving surface required in clay soil structures in Cat 4,5,6. In addition refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe.
- Specialist soils advice & special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS 1547
+ All Sloping sites require special consideration and management through design of slope percentage, surface water and construction methods as per AS1547.
- Plumbers are reminded that good construction techniques as per AS 1547 are especilly important in these soil types. Refer AS1547 & AES installation Instructions
Total System load - litres / day (Q). 480 Vd AES System Extension Area
Min Length of AES pipe rows to treat loading 8.0 Im ILth m: (L)
Number of FULL AES Pipe lengths per row 3 Iths Width m:(W)
Sane 0.75 0.15
Total Capacity of AES System pipe in Litres 1272 Ite. | Denth : ‘i .
Area m2 13.0 47.0
USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER. I | >>Slope percentage must be 0% & infiltration footprint must be level |
IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y’ | Y Enter Custom Width in metre 4
AES INFILTRATION FOOT PRINT AREA. L=Q/(DLRxW) | Length Width Minimum AES foot print required .
The length & width of excavation required for this design is >> “a x ‘ = a m2 total
A trench design has a max of 2 rows of AES pipes located 300mm from up slope side and centered lenght wise in the (reneh is better.
ace Gans GG Sis tie eee
AES-PIPE AES 3 mtr Lths required 6 ths: Digitally signed by
AESC AESC Couplings required 4 ca Steve Dennis
DN: cn=Steve
AESO AESO Offset adaptors 4 ca ,
" Dennis, o=Chankar|
AESODV AES Oxgen demand vent 1 a Enviromental,
AES IPB AES 100mm Inspection point base 2 ca G@ Agvanced,__..ou=Design
“ious Werewsrrsoition™ Review,
AES Equ AES Speed Flow Equaliser ca emfitesteye@envir
AES DESC Double Offset Adaptors ca o-septic.com.au,
c=US
TOTAL SYSTEM SAND REQUIRED (Guide Only) 20 m3
Date: 2022.02.03
PLEASE email your AES CALC and Dray 11:51:34 +10'00'
DESIG [email protected] Dotiguveclon iecarion nepal creme
> The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only, Sire and soil
conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer
> Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.
> AES pipes can be cut to length on site. They are supplied in 3 meter Iths only
AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty Itd 14/3/2016
Page 26
ADVANCED ENVIRO-SEPTIC’ Advanced Envyiro-septic Design Calculator V8.8 © “Always The First Option” Leader in Passive Solutions _ ‘ieee LOT 2 $P241381 SISTER TREE CREEK ROAD, KIN KIN CABINS 3 & 4 State QLD Post Code 4571 Client N: JODIE WILLIAMS Date of Site Visit 31/02/2022 jame si Designers Ph = DsSiBDES 4S TRELOAR, UNEARTHED GEOTECHNICAL P/L. oe 0417 132 300 Number QBCC740251 Name Number Plumber Ph Plumb / Drainer Plumber Number Lic Number Council Designers AES NOOSA Cert Number Date 2/2/2022 This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer. Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 [>> This design is for an ADVANCED SECONDARY system Is this a new installation Y or N ¥ >> Minimun single vent size is 80mm or 2 x 50mm house vents Number of person 4 a septic tank outlet filter is NOT RECOMMENDED Daily Design Flow Allowance Litre/Person/Day 120 Number of rows required to suit site constrants z >>The maximum length of a single AES pipe run is 30 meters Infiltration surface Soil Cat as est by site/soil evaluation. CATEGORY § >> Catagory may require design considerations. Ref AS 1547 Design Loading Rate based on site & soil evaluation DLR (mm/day) 8 >> Soil conditioning may be necessary. Ref AS1547 & Comments. Bore log depth below system Basel area 600 |>>Min depth below basel area 600mm check water table/restrictive laye AES FOOTPRINT MUST BE LEVEL WITH TRENCH EXTENSION 7 |>>Consideration reqd for Sloping sites. Ref AS 1547. refer comment. Is this design a gravity system with no outlet filter? Y or N Y >> A House Vent & LOW VENT required on this system PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES COMMENTS : " The outcome must be important to everyone. + Ripping of receiving surface required in clay soil structures in Cat 4,5,6. In addition refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe. + Specialist soils advice & special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547 ~ All Sloping sites require special consideration and management through design of slope percentage, surface water and construction methods as per AS1547. - Plumbers are reminded that good construction techniques as per AS1547 are especilly Important in these soil types. Refer AS 1547 & AES installation Instructions Total System load - litres / day (Q). 480 Vd AES System Extension Area Min Length of AES pipe rows to treat loading 8.0 Im Lith m : (L) Number of FULL AES Pipe lengths per row 3 Iths Width m:(W, ~~ 0.75 0.15 Total Capacity of AES System pipe in Litres 1272 ltr. z . “ Area m2 13.0 47.0 USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER yf | >>Slope percentage must be 0% & infiltration footprint must be level | IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER | Y Enter Custom Width in metre 4 AES INFILTRATION FOOT PRINT AREA- L=Q/(DLRxW) | Length Width Minimum AES foot print required . The length & width of excavation required for this design is >> 15.0 x 4 = 60.0 ‘m2 total A trench design has a max of 2 rows of AES pipes located 300mm from up slope side and centered lenght wise in the trench is better. AES-PIPE AES 3 mtr Lths required 6 Iths ee eed sed 4 Digitally signed by ‘ouplings ca ; eninge was Steve Dennis AESO AESO Offset adaptors 4 ca DN: cn=Steve AESODV AES Oxgen demand vent 1 ca Dennis, o=Chankar Enviromental, AES-IPB AES 100mm Inspection point base 2 ea IG BNViNG-SePTIC” ou=Design Review, "Ratu Wastewater Saltions™ AES Equ AES Speed Flow Equaliser ca email=steve@envir o-septic.com.au, AES DESC Double Offset Adaptors ea c=US TOTAL SYSTEM SAND REQUIRED (Guide Only) 20 m3 Date: 2022.02.03 PLE 11:51:51 +10'00' Femail your AES CALC and Drawings (o [email protected] [email protected] > The AES Calculator is a design aid 10 allow checking of the AES components and configuration and is a guide only, Site and soit conditions referencing the AS 1547 standard are calculated und designed by « Quailified Designer > Chankar Environmental has no responsibitity for the soit evaluation, loading calculations or DLR emered by the designer for this cateulaior pipes can be cut to length on site. They are supplied in 3 meter lths only AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty ltd 14/3/2016
Page 27
KIN KIN CREEK
EXISTING/PROPOSED
DEVELOPMENT SITE
100 0 100 200 300 m <| b
; A
SCALE | : 5000 \\synology\General\JOBS\022-003-SisterTreeCreek\022-003-Drawings.dwg|
CLIENT: JODIE WILLIAMS (0488 569 020) 51/01/2022 Uneanian GEOTECHMEAL AND SHALL NET BE COPED
Lot 2 SP241381 SISTER TREE CREEK RD, OniG. SHEET SWE Al
KIN KIN. NOOSA COUNCIL SCALE: 1-5000
UNEARTHED GEOTECHNICAL P/L 022-003
A.J. TRELOAR QBCC Lic. No.740251 PO Box 1204, GYMPIE, QLD 4570 _O4I7 152 500 [email protected]] PLAN NO. -
Page 28
|
|
att BH 5 24
ve -—_—
nh ' S
' &
¥
EXISTING SEPTIC 3
® tank
PROPOSED
CABIN 5
INTERNAL PROPERTY FENCING
EXISTING SHEDS
PROPOSED
EXISTING SEPTIC TANK
SOOOLT SEPTIC TANKS (LOCATIONS TO BE DETERMINED ON-SITE)
t | EXPECTED LAND APPLICATION DESIGN AREAS (CABINS | & 2, CABINS 5 & 4)
SQ PTETEIIEETED® EXCAVATED SURFACE WATER DIVERSION DRAIN (SUGGESTED MIN. 500MM WIDE, 50MM DEEP)
20 0 0 20 40 60™
SCALE | : 1000 .
\\synology\General\JOBS\022-003-SisterTreeCreek\022-003-Drawings.dwg
CLIENT: JODIE WILLIAMS (0488 569 020) 51/01/2022 thea ene sae cn
LoT 2 SP241581 SISTER TREE CREEK RD, See Srecy Sue Ab
AN KIN. Noosa cou SCALE. 11000
NEARTHED GEOTECHNICAL
PO Box 1204, GYMPIE, GLD 4570 _O4I7 132 $00 [email protected]| PLAN No. 022-003
A.J. TRELOAR QBCC Lic. No.740251
Page 29
AES PIPES SYSTEM SAND OFFSET ADAPTOR COUPLINGS RAISED CONNECTION | | VELOCITY DIFFUSER, INLET & HIGH VENT IF PUMPED INLET WITH HIGH VENT ON HOUSE IF GRAVITY FED Low VENT bf] I uo By ISSO 2650MM SAND BED EXTENSION INSPECTION PORTS; ——_______y, 2700MM 9600MM 2700MM 100MM LOW VENT INSTALL WITH A MOSQUITO PROOF STAINLESS STEEL MESH. FIXED TO BOLLARD Le ELBOW LEVEL WITH TOP OF OFFSET ADAPTER 150MM REPLACED TOPSOIL 150mm 50-100MM LEVEL, 3 I = SLOPE HHH q | — OFFSET ADAPTER AES | io VENT DETAIL [_svsren saw | \\synology\General\JOBS\022-003-SisterTreeCreek\022-003-Drawings.dwg} CLIENT: JoDIE WILLIAMS (0488 569 020) 31/01/2022 | Sems'sareaa set we core LoT 2 SP24138| SISTER TREE CREEK RD, aaa, SucET See AE KIN KIN. | NOOSA COUNCIL SCALE: NTS UNEARTHED GEOTECHNICAL P/L PLAN No. 022-003 A.J. TRELOAR QBCC Lic. No.74025!_ PO Box 1204, GYMPIE, QLD 4570 0417 132 300 [email protected]
Page 30
“MSHLVAM LAM 4O SdOldad YSLAV LSNF YO ONINNG LONYLSNOD YO TOS SHL YYOMYSAO LON 0d “ALINSSLNI TOS ONILSIX JAYASAYd “WOS/OY G'O LV WNSdAD/ALINOTON ONIGAV ‘SAdIid 4O AVI 3HL OL TATIVAWd ‘YNOLNOD 3H1L ONOIV WNOOZ 40 Hiddd V OL daddild 38 OL VauV IvSVa YING WWOOd OL Gaddild da33d 38 OL Vay S & wo wo - w ow s s $ gag? ge g 2 s s88 8 = = = z = = =z =z =z =z = = =z =z wnost || NOISNaixa O56 WSISAS << a AL, wHos}| moog AK ay ™® Tayovg 0 WHOOS AK . WHOS! ogi] | 140d NOILDAdSN] a 13437 GNNO¥9 ONIuSixa TlosdoL a30Vv1d3y GNVS WALSAS 140d NOILDAdSN| dadWNd Jl LN3A HOIH ‘dad ALIAVYS dl LNSA MOT (ddad WWOS| ‘30IM WNO0G ‘NIN daLS399NS) NIVYG NOISYSAIG NALVM Jdv4UNs d3ALVAVIXA (ONIGNOd LNSAZYd OL YSLVM 3OVANNS LIIT4IG OL dadVHS) (H9IH WWOS] ‘3GIM WWOOO! ‘NIN daLS399NS) Y444NG NOILVYIdSNVYL/GNNOW NOILNSLIY GaLVLa939A aat0Y woval \\synology\General\JOBS\022-003-SisterTreeCreek\022-003-Drawings.dwg UNEARTHED GEOTECHNICAL AND SHALL NOT BE COPIED (OR REPRODUCED WITHOUT THE APPROVAL OF UNEARTHED GEOTECHNICAL ORIG. SHEET SIZE: A& SCALE: NTS COPYRIGHT: THESE PLANS ARE THE PROPERTY OF PLAN No. 022-003 31/01/2022 CLIENT: JODIE WILLIAMS (0488 569 020) LoT 2 SP24138| SISTER TREE CREEK RD, NoosA COUNCIL UNEARTHED GEOTECHNICAL P/L A.J. TRELOAR QBCC Lic. No.740251 KIN KIN. PO Box 1204, GYMPIE, QLD 4570 0417 152 300 _UNEARTHED@TPG. COM. AU
Page 31
a ju a & = a a a oO qt > 2 LE a a lu z = “a Ww = ow 2) = 9 = o co oO wi o 8 Y in fo) = a a Be ez wu Ww ke < = a Ww <x > b hi S| ot E Ww wu no wy = | LL wat n Wu 1 oa >|o So 2a iu _ wi fF 2m S| ou “uy Us 26 _e£ oan Zz WS J ZeE a zs F Ly = eS a z z a) 2/3 S = A. ale FF uw Yo im > >| al a z o =| = Ss er z=} 0 Oo 5 5 C uu 7) ” < oO aw NN ao > Zz in \\synology\General\WJOBS\022-003-SisterTreeCreek\022-003-Drawings.dwg CLIENT: JobIE WILLIAMS (0488 569 020) 31/01/2022 Uneartheo Geovechmeat a1 SHA MET 8 COPED LoT 2 SP24138I SISTER TREE CREEK Rp, ORIG. SHEET SIZE: A& KIN KIN. _ NOOSA COUNCIL SCALE. NTS UNEARTHED GEOTECHNICAL P/L 022-003 A.J. TRELOAR QBCC Lic. No.74025! PO Box 1204, GYMPIE, QLD 4570 O4I7 132 300 [email protected]| PLAN NO. -