As the slope configuration was recorded to be linear planar the Land Application Areas shall be protected from surface water infiltration by the installation of an excavated surface water diversion drain (suggested minimum 1000mm wide and 150mm deep) and from runoff by the installation of a vegetated track rolled retention mound/transpiration buffer zone (suggested minimum 1000mm wide and 150mm high). In this instance the drainage characteristics of the consistent soil profile, and the topographical location of the proposed Land Application Areas (i.e. adjacent to, and downslope of the well-formed pad) may be deemed to offer some, or sufficient protection from surface water infiltration. ‘Similarly, the existing endemic vegetation, extending more than 30 m downslope of the proposed Land Application Areas may be deemed to be satisfactory as the recommended transpiration buffer zone. It is essential that all associated stormwater flows from this and neighbouring allotments, driveways, roads, tanks and roofs are diverted away and well clear of the proposed Land Application Areas by proper final grade of the finished surface. We recommend the base of the entire excavations and the existing ground immediately downslope of the AES trench (approximately 1m) shall be ripped, along the contour and parallel to the lay of pipes, to a depth of 200mm prior to the construction of the AES installation, whilst adding dolomite/gypsum at nominal rate (say 0.5 kg/sqm). During the excavation processes we recommend separation of the brown topsoil (to be spread over the top of the entire installation to facilitate grass growth) from the orange/red/brown subsoil which is used to backfill the sand bed. We further recommend a minimum depth of cover at the low side of the sand bed extension of 300mm. Unearthed Geotechnical P/L. 10 Design Report 022-003
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.