Plans Altered 26 Crystal St Cooroy 27-04-20 · OPW20/0083

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                                                                                                                      Notes for Construction & Maintenance of Timber Decks:
                                                                                                                                                                                                                                                    Timber Queensland recommend that all timber has a moisture content of 15%
                                                                                                                                      Builder to adhere manufactures specifications or industry standards at all times &                            Decking boards to be fixed with 2/nails or screws & staggered or offset along the
                                                                                                                                      Owners to follow manufactures details for maintenance & cleaning of deck                                      joists. Holes at ends of boards to be drilled holes to be 80% of nail diameter &
                                                                                                                                      All timber posts to be naturally durable Class 1 or 2 above ground or softwoods H3                            12mm from ends of boards. Nails & screws to finish flush with top of boards (Not
                                                                                                                                      treated if supported on bracket if in ground to be H5 Treated soft or hardwood.                               Punched). Nails or screws to be hot dipped galvanized or stainless steel. Stainless
                                                                                                                                      Recommend brackets or supports be used & Bitumen paint be applied to the top                                  Steel to be used within 900 mm of pools
                                                                                                                                      200 mm of bracket in the concrete.                                                                            All Framing Anchors, Fixing Plates, Nailing Plates, Joist hangers to be Galvanised
                                                                                                                                      Posts to have a Minimum 75 mm clearance from the base of the post to footing or                               Minimum or Stainless Steel where Construction within 2.0 km radius of open coastal
                                                                                                                                      slab & post to be 10 mm above cross member of bracket. End grain of post to be                                areas
                                                                                                                                      sealed prior to erecting.                                                                                     Ends of boards to be slightly undercut at joints. Gaps between decking boards to be
                                                                                                                                      Top of concrete pad footing to be mounded to fall away from support to prevent                                min 3 mm to 5 mm
                                                                                                                                      water from ponding                                                                                            (Check with supplier Gaps range with different Types of timbers)
                                                                                                                                      Bearers, Hardwood to be H3 treated if less than 400 mm above ground H4 for                                    Decking boards to be fully sealed (Oiled, Stained, Painted etc.) prior to fixing.
                                                                                                                                      touching ground H5 for in ground.                                                                             Recommend a light coloured sealer, with UV protection and a fungicide to be used
                                                                                                                                      Joists as bearers depending on ground clearance. Joists to have Malthoid strip or
                                                                                                                                      bituminous paper fixed to top of joists. Softwood & Engineered manufactured                                   Maintenance & inspection of deck by Owner is to be carried out regularly
                                                                                                                                      timbers bearers & joists to be H3 min treated at all times. Approved connectors be                            Sweep or blow, leaf or other debris off deck. Hosing or use of water to be avoided.
                                                                                                                                      used for treated timbers & location.                                                                          Keep the gaps between decking boards clear of dirt & debris.
                                                                                                                                      Recommend hot dip galvanized or stainless steel connectors & fixings be used at all                           Reseal decking boards when required by manufactures recommendations
                                                                                                                                      times. Especially where inspections are not possible deck is to close to ground or                            Inspect all connections for corrosion or movement regularly (Twice Yearly)
                                                                                                                                      decking to be screwed in place to allow for easy removal to inspect sub-floor for any                         Pot plants to be on stands with a drip tray underneath & moved around regularly to
                                                                                                                                      issues.                                                                                                       prevent uneven weathering of the deck

                                                                                                                                                                                                                                                    Accolade Building Designs recommends that Builder & Home Owners read Domestic
                                                                                                                                                                                                                                                    Deck Design Guide
                                                                                                                                                                                                                                                    Available on line www.timber.net.au



             Colorbond Custom Orb to Manufactures details
             Fixed for N3 Wind rating                                                                                                                                                       20°
             Approved type roof battens @ 900 Crs.
             Fixed to Manufactures details for N3

             Roof Trusses to Manufactures details @ 900 Crs.
             30 mm Gal Strap 4/30 mm nails per leg                                                                                              Insulation to Energy Efficiency Consultants details


                                                                                                                                     Ceiling Plasterboard 10 mm thick
                                                                                                                                       Cornice to Owners selection
             Lintels to Win/Door Schedules

                                                                                                                                                                                                                                                                                Top Plates 2/70x45 MGP12
                                                                                                                   Ceiling 2700 mm                                                                                                 Colorbond Cladding
                                                                                                                                                                                                                                                                                Carport Roof

                                                                                                                                                                                                                                          W16

                                                                                                                                                                                                                                                                                Tie-down Rods 12 mm Ø at 1200 crs
                                                                             Privacy Screen       Privacy Screen                                                                                                                                                                NON Load bearing wall 70x35 MGP10 Timber frame
                                                                                                                                                                                                                                                                                Studs @ 450 crs
                                                                                                                                        Bed 2                                                         Passage            Laundry
                                                                                                                                                                                                                                                                                Bottom Plates 70x45 MGP12

                                                                                                                                                                                                                                                                                J2: Floor Joists @ 450 Crs.
                                                                                                                                                                                                                                                                                1/Framing anchor 4/30 mm nails per leg
                                                                                                                                                                                       Sub-Floor Bracing to Engineers details
                                                                                                                                                                                                                                                                                B2: 2/M12 bolts to SHS posts

                                                                                                                                                                                                                                                                                C3: Galv SHS posts to engineers details


                         Section A                                                                                                                                                                                                                                              Carport Concrete Slab 100 mm thick to Engineers details


            A              1 : 50
                                                                                                                                                                                                                                                                                Concrete blocks to base 200 Series to Engineers details

                                                                                                                                                       Ground to be scraped clean of vegetation                                                                                 Reinforced Footing to Engineers details
                                                                                                                                             Ground to be graded so water DOES NOT pond under building




Client: Brad Allen                     Address: 26 Crystal St. Cooroy                                Noosa Shire Council                                                                                                                               Mobile: 0407 693 018        Date     27/04/2020 11:26:06 AM
                                                                                                                                                                         ACCOLADE Building Designs                                                                                 Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 28 on RP 32777                              Site Area : 1374.8 m²               Wind Classification N3                                                                        Proprietor: Steven Horn                                  Email: [email protected]
                                                                                                                                                                                                                                                                                                                Project Number                 1118AB28
Proposed New Residence, Carport & Second Residence on SHS posts, Timber Frame, Sheet Roof                                                                                               QBSA Lic. 54806                                         Issue Date:        27 - APRIL - 2020                            Scale      1 : 50    Sheet No. 6   of 13

Used in these records

About this file

File size
1.1 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Plans Altered 26 Crystal St Cooroy 27-04-20.pdf · 1.1 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.