07/1010 - MCU - Multiple Housing Type 2 Duplex [As Published] · 132007.1010
Ail Residential Uses Code Cro Specific Outcomes Effects of-use 2 orld Probable solutions (if code assessable) Column 3 Compliance Electricity supply infrastructure Of The development does not adversely impact on existing or future electricity supply infrastructure; AND O02 = Alluses and works maintain an adequate safe distance from electrical infrastructure including substations, overhead powerlines, power poles and transformers. Hot water systems are installed and operated to support the efficient use of natural resources and minimise consequent pollution such as greenhouse gas emissions. Water supply and conservation 04 On-site water storage is designed and operated to support the efficient use of water; AND 05 On-site water storage is adequate for occupants every day use and fire fighting purposes. Erasion and sediment control Q6 Development does not cause erosion or result in transport of sediments off-site. $1.1 No solution provided $2.1 Development for uses adjacent to or within 50m of an existing electricity substation incorporates noise attenuation measures to mitigate noise impacts; AND $2.2 Buildings and structures (including swimming pools, sheds, tennis courts or outbuildings) are not constructed under overhead electricity transmission lines, or within electricity easements; AND $2.3 A minimum separation distance is maintained from the electricity transmission line to the closest boundary of habitable buildings and child activity areas, as follows— a) 20m for transmission lines up to 132kV; b) 30m for transmission lines between 133kV and 275kV; and 40m for transmission fines greater than 275kV. aus $3.1 All hot water systems installed are— a) "solar systems; or b) electric heat pump systems; or ¢) natural gas or LPG systems; or d) any combination of a), b) orc). $4.1 Ifin a designated rainwater tank area as identified in Map 1 of Schedule 8, residential uses that qualify as class 1A or 1B structures under the Building Code of Australia have a rainwater tank or tanks in accordance with Schedule 8. AND $5.1 Where not in a water service area a rainwater tank of a minimum of 60,000 litres is provided for each dwelling unit, with the exception of Multiple Housing Type 1. No solution provided. Advisory: Notes. s Persons undertaking:develop building. ' This does not apply to buildings which qualify as Class 1A or 1B structures under the Building code of Australia Residential Code - Wellclose Pastoral SR ARE I CEG gE ESTER ELI SE Rig RRR ARLENE ESOS, ae st ed Not applicable. A condition may be recommended accordingly. A condition may be recommended accordingly. po A condition may be recommended accordingly. Page 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1010 - MCU - Multiple Housing Type 2 Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.