Figure 3. Natural Hazard Management Area (NHMA)mapping (Source:The Noosa Plan 2011)
The hazard classification is a general one, performed as a guide only, for planning purposes and subject to
ground truthing and validation on the basis of more specific local conditions.
It is noted that the subsequent Sunshine Coast Regional Planning Scheme (Overlay Map OVM23E October
-
2012) does not designate the land as bushfire prone.
3.2 Vegetation Assessment, Slope and Separation Distances from Proposed
Development
In the context of AS3959-2009, the predominant vegetation type is "Scrub", both "closed" and "open", due
to the height of vegetation reaching 3 -
4m.The patches of more open dry heath would qualify as
"shrubland" under AS3959-2009, with generally lower fuel accumulation potential.
Effective slope under the fuel zone is flat, however a 2m bank lies east of the proposed "Create" building,
shown in Figure 4, which provides partial radiant heat shielding opportunities,
There is as little as 4m separation between proposed new buildings and intact vegetation. This assessment
serves to determine the required trade off between separation distance and construction level, with and
without the assistance of radiant heat barriers.
Report compiled by Bushfire Risk Reducers for Fulton Trotter Architects, April 2013 Page 7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 2 - Application Plans, Bushfire Management Plan and Fire and Evac Plan - OPW13/0463Related documentApplication case desk ↗
About this file
- File size
- 76.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.