Original source · versioned page text
Att 1 - Code Assessment
may incorporate solidtranslucent
screens, shutters, perforated panels
or trellises which have a maximum of
50% openings.
Editor's note—refer to figure AP3-1B
PO17 AO17.1 Performance Solution
Development, including mechanical Communal outdoor recreational Refer to 7.5.1 of the Development
Assessment Report.
plant, vehicle manoeuvring and facilities including swimming pools,
communal outdoor recreation uses: spas and sports courts are:
(a) do not have an adverse (a) setback at least 12 metres
effect on the amenity from the boundary of land in a
enjoyed by users of residential zone and screened
adjacent or nearby by a 5 metre wide buffer
premises through emission densely planted with trees and
ofnoise, light, fumes or shrubs including species from1
smoke; metre to 8 metres in height; or
(b) do not cause (b) located internally to the
unreasonable arrangement of buildings on
disturbance to local the site;and
faunathrough light or (c) not used between the
smoke emissions. hours of 9:00pm and
6:30am thefollowing day
AO17.2 Not Applicable
For a lit sports court:
(a) the court is located at least
60 metres from the external
wallof an existing or
approved dwelling on
adjoining or nearby premises
(as measured from the centre
line of the court); and
(b) the vertical illumination
resulting from direct, reflected
or other incidental light
emanating from the site does
not exceed 8 lux when
measured at any point 1.5
metres outsidethe boundary
and at any level from ground
level upward; and
(c) any flood lighting is restricted
to the types that give no
upward component of light
where mounted horizontally
(i.e. afull cut off luminare)
AO17.3 Complies
Mechanical plant is:
(a) located at least 2
metres from side or
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.