Original source · versioned page text
Engineering Drawings
Original PDF page 9, section 1. The text section number identifies this passage in the reader.
STRUCTURE NAME 1-1 2-1 3-1 4-1 5-1
SIEVE SIZE (mm) WEIGHT PASSING (%) NOTE:
EXISTING ROAD GULLY PIT
OPENING BETWEEN PITS
STD 1050Ø MANHOLE
STD 1050Ø MANHOLE
· CONSTRUCTION TRAFFIC TO BE EXCLUDED FROM
1200x1200 MANHOLE
PITSWITH 450Ø
75.0 -
2/900x900 GRATED
PIPEWORK TRENCHES UNTIL SUCH TIME AS PAVEMENT
STRUCTURE 19.0 100 OVERLAY IS COMPLETE & WRITTEN APPROVAL IS
DESCRIPTION 9.50 - RECEIVED FROM THE SUPERINTENDANT
INLETPITS
2.36 50 - 100 · WHERE IT IS IMPRACTICAL TO EXCLUDE CONSTRUCTION
TRAFFIC ALL WHEEL LOADS MUST BE CONFINED TO 20mm
INLET
0.60 20 - 90
STEEL BRIDGING PLATES AS DETAILED
0.30 10 - 60 · BEDDING/HANCHING MATERIALS & BACKFILL TO BE
0.15 0 - 25 COMPACTED IN LAYERS NOT EXCEEDING 150mm THICK
0.075 0 - 10 USING VIBRATING PLATE OR SIMILAR COMPACTILE EFFORT.
HYDRAULIC COMPACTION ALONE IS UNACCEPTABLE.
BEDDING MATERIAL GRADING UNITS · BEDDING/HAUNCHING MATERIAL TO BE COMPACTED AT
MOISTURE CONTENT 60% > OPTIMUM > 90% AS
DETERMINED AS1289.5.7.1 (STD)
EXISTING NOTE: · TRENCH COMPACTION TESTING TO BE CARRIED OUT AT
SYRFACE THE FOLLOWING INTERVALS WITH ALL RESULTS
ALL WORKS TO BE CARRIED OUT SUBMITTED TO THE SUPERINTENDENT FOR APPROVAL:-
IN ACCORDANCE WITH COUNCIL
DESIGN · SELECT PIPE BACKFILL:
SURFACE
GUIDELINES - 1 TEST EACH DRAINAGE LINE
BIO
BASIN
20mm THICK BRIDGING PLATE (1000mm WIDE MIN)
WHERE TRAVERSED BY CONSTRUCTION TRAFFIC
PRIOR TO PAVEMENT COMPLETION
1000 1000
MIN MIN
TYPE 2.5 GRANULAR LOWER
IL 3.53
150Ø WATER
SUB BASE <100mm COMPACT
MIN
300
300
TO 100% MDD IN
ACCORDANCE AS1289.1 (STD)
GRANULAR BEDDING MATERIAL IN
MIN
100
ACCORDANCE WITH GRADING
CONTRACTOR TO CONFIRM THE LIMITS BELOW. COMPACT TO 70%
EXISTING STORMWATER PIT INVERT
450Ø OPENING MDD IN ACCORDANCE
LEVEL PRIOR TO COMMENCEMENT
BETWEEN PITS 2-1 & 3-1 AS11289.5.7.11 (STD)
OF CONSTRUCTION
300 300
uPVC (SN8)
OB 3.410
MIN MIN
150Ø
STORMWATER TRENCH DETAIL
SCALE 1:25 A1
Datum 1.500
REFER LONG
PIPE LENGTH (m) 16.080 1.231 8.533 3.178 5.489 SECTIONS FOR
PIPE SIZEmm (Class) 375Ø 375Ø
450Ø 450Ø 450Ø 450Ø GRATE SIZE
RCP (3) RCP (2) RCP (3)
OPENING RCP (3) RCP (3) 150 & CLASS 150 REFER LONG
50 50 SUBSOIL FLUSH OUT SOCKED SECTIONS FOR
PIPE GRADE % 1.00% 0.00% 1.00% 4.62% 1.46%
100dia x 600 LONG uPVC & GRATE SIZE
PIPE SLOPE 1 in X SCREWCAP (UPSTREAM)
50
150 & CLASS 150
PIPE FLOW (m3/s) KERB AND CHANNEL PIT ONLY
150
0.120 0.177 0.177 0.177 50 50
PIPE CAPACITY (m3/s) 0.175 0.285 0.611 0.344
G.L.
SECTIONS FOR
GRATE SIZE &
REFER LONG
2.800
1.484
1.665
1.665
1.494
1.514
1.082
1.690
1.160
CLASS
DEPTH TO INVERT 100dia SOCKED SUBSOIL
GRATE DRAIN DOWNSTREAM KERB
AND CHANNEL PITS ONLY
50
4.000
3.839
3.790
3.790
3.705
3.685
3.538
2.930
2.850
INVERT LEVEL
150
DESIGN SURFACE
4.620
6.800
5.323
5.455
5.198
4.010
LEVEL HEAVY DUTY GRATE TO PROVIDE 100dia SOCKED & CAPPED
MANUFACTURERS SPEC. SLOTTED uPVC BEDDING DRAIN x 1m 100dia SOCKED & CAPPED
REFER LONG SECTION FOR LONG (TYP) (DOWNSTREAM) ALL PITS
REFER DWG
STRUCTURE SETOUT SUBSOIL DRAIN SLOTTED
D01 FOR
SETOUT
N5028.516
N5012.450
N5012.450
N5003.917
N5000.921
E1119.592
E1121.482
E1120.251
E1121.482
E1120.418
GRATE CLASS PIPE DIAMETER AS uPVC BEDDING DRAIN x 1m
150
CO-ORDINATES ALL PIT GRATES TO BE HOT DIP GALVANISED NOMINATED LONG DOWNSTREAM (ALL
(Easting / Northing) PITS)
PLAN
SECTION
25.844
29.022
34.511
16.080
17.311
0.000
CHAINAGE
TYPICAL GRATED PIT DETAILS
1 SCALE 1:20
NOTE: ONLY DRAWINGS MARKED "FOR CONSTRUCTION" AND BEARING AN ORIGINAL SIGNATURE SHALL BE USED FOR CONSTRUCTION Design:
PURPOSES.
SWT PROJECT: DRAWING TITLE:
ALTA PROJECTS
Drawn: SWT
A.B.N. 611355330 STORMWATER DRAINAGE DETAILS
FOR APPROVAL Date: DEC 2017 26 Memorial Avenue, Cotton Tree PROPOSED COMMERCIAL DEVELOPMENT
NOT FOR CONSTRUCTION PO Box 559, Cotton Tree, QLD, 4558 Revision Sheet
C 28/01/2021 ISSUE FOR APPROVAL S.T. S.R. Checked:. . . . . . . . . . .
Tel (07) 5475 4125 Fax (07) 5479 1607 at 30-32 DOONELLA STREET, TEWANTIN QLD DRAWING No:
A6035/21/D02 C 2 of 2
B 27/01/2021 ISSUE FOR APPROVAL S.T. S.R. STEPHEN ROBERTS
Email: [email protected]
A
1
21/01/2021
18/01/2021
ISSUE FOR APPROVAL
CO-ORDINATION ISSUE
S.T.
S.T.
S.R.
SR
.......................
DIRECTOR APPROVAL Datum AHD
Web: http://www.alta.net.au for DONNELLA STREET PTY LTD
REV DATE DESCRIPTION BY CHKD RPEQ - 7665 A1 SHEET SIZE FILENAME : A6035 - D02 STROMWATER DRAINAGE DETAILS.dwg - DATE : 28/1/21 - 4:33pm - XREF's: A6035 C3D Design; H-Approved-SR; H-Checked-SR Council Ref: ...................