Council archive · source document
10/0819 - Operational Works - Jetty [As Published] · 142010.819
PILES:
ALL PILES SHALL BE APPROVED HARDWOOD
AND TREATED TO HAZARD 6.
ALL PILES SHALL BE INSTALLED IN ACCORDANCE
WITH AS 2159 - PILING CODE
JETTY USE:
SINGLE USER, PRIVATE
NO VEHICULAR ACCESS
WALKWAY DECK VERTICAL
DESIGN LIVE LOAD - 2.0 kPa
MAXIMUM MOORED VESSEL - 5m
BERTHING VELOCITY - 0.5 m/sec
SUNSEEKER CLOSE
| ELEVATION 2
WCKER:
75 x 38 HWO
‘UT6 x No14 TYPE 17
STAINLESS STEEL
SCREWS @ 450 CRS
LOT 167
PLES:
@ 200 H6 MARINE HWD POLES
NOTE THAT ALL POLES TO COMPLY
WITH AS 2189 - PILING CODE
TYPICAL SECTION
™ (No.11)
- seonreiamp SUNSEEKER CLOSE
ee muse John Norden
OTE THAT ALL POLES TO COMPLY & Associates
200 x 76 HWD WAT A8 2168 - PILING CODE ACN 010 263 877
Suuchwal / Chl Design Engineers
aay \
1. UNLESS NOTED OTHERWISE ALL TIMBER SHALL BE DURABILITY CLASS 1 OF APPROVED SPECIES
AND HAVE A STRESS GRADE OF F14 MIN.
2. UNLESS NOTED OTHERWISE ALL CONSTRUCTION SHALL COMPLY WITH THE ENVIRONMENTAL
AGENCYS' OPERATIONAL POLICY - “BUILDING AND ENGINEERING STANDARDS FOR TIDAL
3. ALL STAINLESS STEEL BOLTS, RODS, ETC., SHALL BE APPROVED MARINE GRADE 316. ALL OTHER
STEELWORK INCLUDING NUTS, BOLTS, WASHERS, SCREWS, NAILS, ETC., SHALL BE HOT DIPPED
GALVANISED OR STAINLESS STEEL.
/ RP 845980 SITE PLAN 4. TOP OF PILES SHALL BE SEALED AND FULLY CAP FLASHED OR RINGED.
PARISH WEYBA X
FRAMING LAYOUT 2 COUNTY MARCH om 6. DIMENSIONS AND LEVELS SHALL NOT BE SCALED FROM THE DRAWINGS. _—
10/80-1 |
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
10/0819 - Operational Works - Jetty [As Published]Related documentApplication case desk ↗
About this file
- File size
- 915 KB (small file)
- File type
No other editions are linked here.