unit 13, the hastings, noosa parade 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
UPPER FLOOR TOP PLATE SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
UPPER FLOOR JOINERY AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
MANUFACTURERS SPECIFICATIONS.
2400
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
UPPER FLOOR AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
FIRST FLOOR TOP PLATE 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
FIRST FLOOR JOINERY LINE 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
STANDARDS RELATING TO HIS OR HER OWN WORK
2400
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
FIRST FLOOR DOMESTIC SMOKE ALARMS:
GROUND FLOOR TOP PLATE 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
GROUND FLOOR JOINERY LINE PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
awning window SAFETY LEGISLATION AMENDMENT REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
2400
1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
SYSTEMS.
GROUND FLOOR 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
100
(EXISTING DWELLINGS ONLY) THAT CANNOT BE
PAD LEVEL
REMOVED FROM DEVICE
vertical timber cladding alike existing
elevation A elevation B NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
TO EXISTING RESIDENCE
UPPER FLOOR TOP PLATE
UPPER FLOOR JOINERY
2400
UPPER FLOOR
bed
FIRST FLOOR TOP PLATE
FIRST FLOOR JOINERY LINE
2400
FIRST FLOOR kit
GROUND FLOOR TOP PLATE
GROUND FLOOR JOINERY LINE
u/side of joists
2300
2400
vj lined and painted
proposed
between joists, nominal height to 90mm timber framing + cladding
u/side of lining 2400 over alike existing
GROUND FLOOR
slab and footings as required
Section 1 -
elevations
NOOSA COUNCIL
APPROVED PLAN
51983.3225.08 5 APR 2017
elevation C elevation D
PROPOSED: CLIENT: JENIFER BASHFORD BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 4 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0412 104 710 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 MAR 2017 C
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH