Log in to see the plans as drawn NOTES:
unit 5, the hastings, noosa parade
lot 5 on GTP1154
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
TO NOOSA PARADE
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
JOINT GROUP J2.
- 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
APPROVED PLAN SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
AS 1684.2 2010
51983.3225.10 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
NOOSA COUNCIL OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
MANUFACTURERS SPECIFICATIONS.
180d00'30"
1 AUGUST 2017 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
129.960
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
STANDARDS RELATING TO HIS OR HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
DOMESTIC SMOKE ALARMS:
unit 7 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
SAFETY LEGISLATION AMENDMENT REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
SYSTEMS.
unit 6 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
(EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
5050
3000
70.770
NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
0d0'
TO EXISTING RESIDENCE
(PROPOSED
BUILD IN)
4800
2500
3420
unit 5
unit 4 5420
46.300
8d57'
TO HASTINGS STREET
site plan
PROPOSED: CLIENT: PAUL TEYCHENNE BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 1 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 JULY 2017 A
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH