Log in to see the plans as drawn NOTES:
unit 5, the hastings, noosa parade
lot 5 on GTP1154
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
elevation C
04 of 04
90 90 90 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
04 of 04 2270 830 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
01 elevation B JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
bath/l'dry 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
01 store under SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
1209DH AS 1684.2 2010
0606AW existing 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
90
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
tub
u/bench wms
+ dryer over
MANUFACTURERS SPECIFICATIONS.
kit 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
pantry
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
2520
620
shr
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
existing cross bracing
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
720
kitchen to be renovated
11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
90
UP STANDARDS RELATING TO HIS OR HER OWN WORK
EXISTING
entry existing living 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
2121OXSD
CARPORT
0315OXSW
2600
(tiles)
DOMESTIC SMOKE ALARMS:
existing
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
existing
PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
existing 90x90shs posts
90
SAFETY LEGISLATION AMENDMENT REGULATION 2016
0315OXSW 2121OXSD 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
01 existing deck 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
3380 3290 (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
01
NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
TO EXISTING RESIDENCE
Ground Floor First Floor
01
existing 0906AW existing 0906AW
T T
1580
800
recess
S -
APPROVED PLAN
bed S
51983.3225.10
bed
NOOSA COUNCIL
1 AUGUST 2017
proposed floor
01
elevation D
elevation A
04 of 04
Upper Floor 04 of 04
PROPOSED: CLIENT: PAUL TEYCHENNE BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 3 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 JULY 2017 A
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH