450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT METAL ROOF SHEET
(CUSTOM ORB PROFILE) @ 22.5°

ON ENGINEER DESIGNED
TRUSSES

SELECT METAL FASCIA AND
GUTTER

HEBEL POWERPANEL EXTERNAL

WALL CLADDING, SELECT
RENDER FINISH

 

| REAR ELEVATION

 

| 4: 100

400.725 RL - — - — - —

__ 140x140 LAMINATED HWD POST—
ON GALYV, "T" BLADE STIRRUP

 

 

= al. 460 OHANG
SELECT METAL FASCIA AND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT METAL ROOF SHEET

(CUSTOM ORB PROFILE) @ 22.5°

ON ENGINEER DESIGNED
TRUSSES

GUTTER

HEBEL POWERPANEL COLUMN,
SELECT RENDER FINISH

 

 

| LEFT ELEVATION

 

| 1: 100

 

SUNCOAST
BUILDING APPROVALS

  

 

 

No: 1724-68 03 NOV 2017
N86 BISHOP OBCG. 416666
DEVELOPMENT APPROVAL
FOR BUILDING WORKS |
PH: 5443 7288 MOB: 0406 516 167

 

| ALL FIXING AND FLASHING TO BE IN STRICT ACCORDANCE WITH THE
MANUFACTURERS DETAILS. WINDOW SIZES SHOWN ARE NOMINAL ONLY AND
ARE TO BE VERIFIED BY THE BUILDER ON SITE.

SCYON LINEA 180 CLADDING,
PAINT FINISH. JAMES HARDIE
LINEA ALUMINIUM EXTERNAL
SLIMLINE BOXED CORNER
(#305512)

\

2100 JOINERY

 

2550 CEILING

|

 

LEGEND - INTERNAL

AP - APPLIANCE CUPBOARD
BC - BROOM CUPBOARD.
C'BD - CUPBOARD.

OP - DOWNPIPE

OW - DISHWASHER PROV,
FW FLOOR WASTE

GAS - GAS CONNECTION

HP - HOT PLATE

HWS - HOT WATER SYSTEM
L- LINEN

MH - MANHOLE

MW - MICROWAVE PROV.
CHC - OVERHEAD CUPBOARD
PTY - PANTRY

R-ROBE

REF - REFRIDGERATOR SPACE
RH - RANGEHOOD:

SH- SHELF

TR - TOWEL RAIL

TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
WO - WALL OVEN

 

LEGEND - EXTERNAL

BV - BRICK VENEER

CJ- CONTROL JOINT

FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS:
RBB - RENDERED BLUEBOARD
RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
SA-SCYON AXON

SL- SCYON LINEA

SM-~- SCYON MATRIX PANELING
SS - SCYON STRIA CLADDING
WB - HARDIES NEWPORT

 

 

ISSUE

 

#| DATE DETAILS BY

 

}04-08-17| NHP ISSUE DB

 

|23-08-17| WD ISSUE SjB

 

 

A [29-08-17] CONST ISSUE bB.
B | 18-10-17| COUNCIL AMEND] DB

 

 

 

 

 

 

 

 

AUSMAR(®)

 

po box 6384p (07) 54426413
maroochydore (07) 5450 6437
qld 4558 QBCC 1083000

 

This plan remains copyright to

Ausmar Group and may not be

used in part or in whole without

the written consent of the author,
© 2017 Ausmar Group

 

WRITTEN DIMENSIONS TO.
TAKE PRECEDENCE OVER SCALE

 

ELEVATIONS

 

PROJECT DESCRIPTION:
Proposed Dwelling For:

 

CLIENT:
MR R, & MRS L. WILCOX

 

SITE ADDRESS:
LOT 35 (#8)
SUPPLEJACK COURT

LAKE MacDONALD

 

DESIGNED BY AUSMAR

 

DRAWN BY AUSMAR

SCALE | Jon ~ 7
Tae JOB CODE

 

 

CONSTRUCTION PLAN

18-10-17

 

ISSUE

 

ALEXANDRIA - TRADITIONAL (MOD)

oe | S-RLW

18-10-17

 

 

SHEET 4 oF 13

 

 

 

 
Log in to download the original file

Plans 1.pdf · 1.7 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.