Information Request MCU23 0008 [As Published] · MCU23/0008
Issue – Crossover & Pram Ramp Separation
There is no separation between the proposed driveway crossover and existing pedestrian
pram ramp. Council is concerned this lack of separation may compromise pedestrian safety
and results in a large expanse of concrete across the frontage.
Information Required
11. Provide amended plans demonstrating that the location of the proposed crossover has
suitable separation and will not compromise the safety of pedestrians waiting to cross
Rufous Street at the existing pedestrian pram ramp. The amended plans must be
prepared by a suitably qualified person (RPEQ – Registered Professional Engineer of
Queensland).
Issue – Discharge Point of Proposed Grate Drain
SCG Consulting’s Concept Stormwater Management Plan (32304-C3.1) dated December
2022 does not demonstrate how stormwater collected by the proposed grate drain will
discharge.
Information Required
12. Provide an amended plan demonstrating where the proposed grate drain will discharge
to. The amended plan must be prepared by a suitably qualified person (RPEQ –
Registered Professional Engineer of Queensland).
Issue – ‘Small Car’ Carpark
SCG Consulting’s Concept Stormwater Management Plan (32304-C3.1) dated December
2022 notes that two of the northern Car Stackers are for ‘Small Cars’. This is not noted in
Black Wood Architecture’s or Fernway Engineering’s plans and Council believes this is an
error.
Information Required
13. Provide an amended Concept Stormwater Management Plan that removes the ‘Small
Car’ annotations.
14. If the ‘Small Car’ annotation is intended, provide additional detail demonstrating how this
affects the functionality of the carpark as described in Sections 5.4 and 6.0 of Fernway
Engineering’s Traffic Impact Statement dated December 2022.
Issue - Landscaping
The proposal plans do not demonstrate the necessary landscape area to ensure appropriate
levels of screening and buffer can occur that suits the relative size and nature of the
development and reduce the visual impacts of the bulky nature of the development. Refer
PO10 of the Business Activities code and the Landscaping Code and The design has not
provided meaningful dimensioned areas of landscape area along the front, side and rear
boundaries capable of supporting mature screening vegetation for the longevity of the
development.
Information Required
15. Provide detailed landscape concept plans prepared by a suitably qualified landscape
architect in accordance with the requirements of the PSP2 – Landscaping, and that
incorporate the following:
Page 5 of 6
Document Set ID: 22290166
Version: 4, Version Date: 07/03/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Information Request MCU23 0008 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 129 KB (small file)
- File type
No other editions are linked here.