Council archive · source document
Appendix B - Assessment against Applicable Assement Provisions and Benchmarks · 132005.1133.15
NOOSA PLAN 2020
BUSINESS ACTIVITIES CODE
Performance Outcomes Acceptable Solutions Comments
Building design & siting
Ground floor AO6 AO6 Not applicable. The change is a minor change to an
PO6 Ground floor spaces have a minimum ceiling height of 3.5 existing building.
Ground floor spaces and ceiling heights are flexible to cater metres to allow flexibility of use (for example; adaptation
for a range of business activities. for shop, restaurant or office uses)
Outdoor areas AO7 AO7 Complies. The original siting of the existing building has
PO7 Outdoor areas and roof top areas used for business positioned as far as practical from sensitive uses. The
Outdoor areas, including balconies and rooftops, used for activities are located away from sensitive land uses and are change is a minor change to an existing building to enclose
business activities are located, designed and operated to generally oriented towards the street. the existing defined outdoor areas which will ensure that
avoid causing nuisance to adjoining or nearby sensitive land the Restaurant can operate without causing nuisance on
uses. nearby sensitive uses.
Outdoor Dining areas AO8.1 AO8.1 – AO8.4 Not applicable. The restaurant outdoor
PO8 Walls to outdoor dining areas are: dining area as part of this change application will be
Outdoor dining areas are designed and located so that: (a)if facing a roadway or other public area, transparent and enclosed to ensure that it can be also used as an indoor
(a)structures are aesthetically pleasing and in keeping with don’t restrict airflow; dining space.
the existing character of the area, including the architecture (b)separated from the floor and any roof by a minimum
of the associated building; vertical gap of 500 millimetres; and
(b)outdoor dining adds to the streetscape without (c)if detachable or collapsible, are only used during
increasing perceived building bulk; inclement weather.
(c)temporary walls or roofs are retracted when not in use
and secured at all times; AO8.2
(d)the use does not pose a health and safety risk to patrons; Roof, walls or other structures do not extend beyond the
(e)adequate air movement is available; and boundaries of the premises.
(f)structures do not impede the movement of pedestrians or
vehicles. AO8.3
Outdoor dining areas:
(a)have a non‐slip surface which is water resistant and not
raised; and
(b)ensures that where heating is provided it does not
present a physical risk to diners or pose a fire risk to the
surrounding buildings and structures (braziers are not
permitted).
AO8.4
JFP Ref: M2652/F Page 18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix B - Assessment against Applicable Assement Provisions and Benchmarks.pdfRelated documentApplication case desk ↗
About this file
- File size
- 295 KB (small file)
- File type
No other editions are linked here.