BUSINESS USES CODE                                                                                                                                                                                  4        mm
Performance Criteria and Acceptable Solutions                                                                                                                                                        ‘ P BRISBANE

           rele emel Dadar N                                   ACCEPTABLE SOLUTIONS                       SOLUTIONS’                                 COMMENTS                                  COUNCIL USE ONLY

14.23 Amenity                                       ,
Visual amenity
046 The facades of industrial buildings do not      $46.1 Where the length of any facade facing a              ¥            The facades of the proposed building will broken up by the use of
present unbroken and continuous blank walls;        street or residential property exceeds 30m, the                         different colours and textures. There will also be steps in the
                                                    design presents a stepped building line and uses                        alignment of the three (3) main elements of the building {ie:
AND                                                 varying colours and materials to break the building                     nursery, warehouse and timber trade sales). Additionally, there is
                                                    bulk.                                                                   an iconic entrance statement.
047 The building design addresses the street;       $47.1 The main entry to the building faces the             v
                                                    street or front customer carparking area.
AND
                                                                                                                            The main entry faces the customer parking area.
048 The minimum boundary setbacks are               $48.1 No solution provided                                 v
landscaped, with no car parking, garbage bins,
outdoor storage areas and the like located within
the boundary setback areas.                                                                                                 The street frontage boundary setbacks will be heavily landscaped.
Site security
049 Suitable day and night safety and security      $49.1 A security fence no less than 1.8m in height         v            2.1m high boundary fences along the side and rear boundaries will
measures are provided to Industrial businesses      encloses the rear and side boundaries of the site                       be utilised to prevent unauthorised access.
to protect people and property;                     and prevents unauthorised access to all outdoor
                                                    parts of the site used for the Industrial business
AND                                                 USE;
                                                    AND
                                                    $49.2 Any proposed office or public space is sited         v            The principle office area of the proposal will be oriented to the front
                                                    and orientated towards the principal frontage of the                    of the building.
                                                    site;
                                                    AND
050 Security fencing does not have a significant    $50.1 Fencing on any frontage is setback an               NIA           No front fencing is proposed.    ;
1     Solution:   ~ = Acceptable Solution                                                                                                                                                                Appendix C
                  A/S = Altemative Solution                                                                                                                                                        business code.doc
                  N/A = Not applicable to this proposal
178-182 Eumundi Noosa Road, Noosaville                               @                                                               ©                                                                        Page 6

Used in these records

About this file

File size
13.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

0015E24E.001.pdf · 13.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.