EXISTING SERVICES CODE co mm
Performance Criteria and Acceptable Solutions \ GRISBANE
PERFORMANCE CRITERIA ACCEPTABLE SOLUTIONS SOLUTIONS’ COMMENTS COUNCIL USE ONLY
Setbacks and easements
01 Development near a sewer, water main, $1.1 The footing of any structure or building is v All structures will be appropriately located in relation to
stormwater drain, overland flow path or associated located clear of the zone of influence but no closer infrastructure.
structure does not— than 1.5m (measured horizontally) from
a) adversely affect the function of the service; infrastructure including sewers, water mains and
b) place an additional load on the service; and stormwater structures; .
c) unduly increase future maintenance costs.
AND
$1.2 No building or structure overhangs the zone of v All structures will be appropriately located in relation to
influence; infrastructure.
AND
$1.3 Finished surface levels maintain a minimum of v All structures will be appropriately located in relation to
600mm of cover, but no greater than 3m of cover to infrastructure.
the underground infrastructure;
AND
$1.4 If the existing surface level is altered, surface v Infrastructure will be adapted to new surface levels.
level services including manholes and inspection
points are altered to match the new surface level;
AND
$1.5 Alterations are constructed in accordance with v Alterations will be in accordance with Council standards.
Sections 3, 4 and 5 of PSP6 -Engineering Design
Standards — Water and Sewerage and Section 4
of PSPS -Engineering Design Standards — Roads,
Drainage and Earthworks;
OR
$1.6 Existing services are relocated and the design
and construction of the relocated services is in
1 Solution: | ~ = Acceptable Solution Appendix C
A/S = Altemative Solution existing services.doc
N/A = Nat applicable to this proposal
178 - 182 Eumundi Noosa Road, Noosaville Page 1See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015E24E.001.pdfRelated documentPublic source context ↗
07/0256 - MCU - Bunnings Warehouse [As Published]Related documentApplication case desk ↗
About this file
- File size
- 13.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.