05. Hales - Planning Report
Attached to the e-mail Operational Works Application OPW20/0117 - 37 Mossman Crt Noosa Heads.
PROJECT URBAN – 20153 13 Jul 2020
fitted with one handrail and
900mm if fitted with a
handrail on each side;
iii) the primary walkway to
multiple berth pontoons has
a maximum width of 1.5m;
and
iv) the maximum width of the
gangway is 1.5m.
S9.7 In Noosa Sound, where quay lines Compliant.
are set, a jetty or pontoon does not The proposed jetty does not
extend into the watercourses beyond extend beyond the 15m quay
the quay line; line.
OR
S9.8 Where no quay lines are set, the
maximum distance a jetty or pontoon
extends into the watercourse is 10m,
unless it can be demonstrated that a
distance in excess of 10m is essential to
safely access the jetty;
AND
S9.9 All attachments to jetties, Compliant.
including but not limited to boat lifts, The safety ladder does not
jetski dradles, floating berths and extend beyond the quay line.
floating pontoons must be located
within the quay line;
AND
S9.10 Pontoons must be structurally Not applicable.
capable of sitting on the sand bed. The proposal is not a pontoon.
Rollers and bracing must account for
this situation;
AND
S9.11 Jetties and pontoons must be Compliant.
free standing and not rely on The proposed jetty does not
connecting to any Council revetment connect to any other structure
wall or other structure. and is supported by timber
piles.
14.166 Design, Construction and Safety – Boat Ramps
O10 Boat ramps are designed S10.1 Where there is an existing Not applicable.
and constructed to:- revetment wall:- The proposed works do not
a) allow access by a wheeled boat a)the levels of a boat ramp surface at include a new boat ramp.
trailer; the revetment wall is no more than
b) ensure that unacceptable risks 150mm above the top of the wall, not
to personal and public safety are more than 500mm below the top of the
unlikely to be caused; wall and not more than 200mm above
c) avoid cluttering of the the existing beach; and
watercourse;
Development Assessment Report Page 40 of 42
Operational Works
37 Mossman Court, Noosa Heads 4567