                                                                                                                                                                                                                  © COPYRIG HT | All rights reserved. This work is copyright and canot be
                                                                                                                                                                                                                  reproduced or use figured dimensionsions.
                                                                                                                                                                                                                  DO NOT SCALE check all dim ensions on site before fabrication or set out.
                                                                                                                                                                                                                  DO NOT COPY in any form or by me ans (graphic, electronic or mechanical,
                                                                                                                                                                                                                  includin g photocopying) without the written permision of Mercury Design.


                                                                                                                                                                                                                   SECTION NOTES
                                                                                                                                                             8m Above Existing Ground Line                        1) CONCRETE SLAB, BLOCKWORK &
                                                                                                                                                                                                                  FOOTING DESIGN TO ENGINEERS
                          Prefabricated timber roof trusses
                                                                                                                                                                                                                  SPECIFICATIONS ON 0.2mm & 50mm
                          designed and installed to
                          manufacturer's specifications
                                                                                                                     15°                                     Colorbond Custom Orb roof sheeting                   MINIMUM SAND BEDDING
                                                                                                                                                             on trusses at 900crs                                 2) 200 SERIES BLOCKWORK CORE FILLED
            Roof                                                                                                                                                                                                  AND REINFORCED TO ENGINEER'S
            8430                                                                                                                                                                                                  SPECIFICATION
                                                                                                                                                             4.5mm FC soffit sheeting fixed to
                          Ceiling insulation as per energy report                                                                                                                                                 3) DISCONTINUOUS CONSTRUCTION TO
                                                                                                                                                             38x50mm GOS H3 HWD battens
                                                                                                                                                                                                                  DETAIL WITH 1x13mm GYPROCK
                          Insulation to all light weight clad walls
   frame

  ceiling




                                                                                                                                                                                                                  PLASTERBOARD CD & TSB4/ASB4
    2600

    2550




                                                                                                                                                             ?
joinery




                          as per energy report
 2100




                                                                                       BED 3                 STUDY                   BED 1       WIR                                                              POLYESTER BATTS AS PER ACCOUSTIC
                                                                                                                                                                                                                  REQUIREMENTS




                                                                                                                                                                                                  7900 at ridge
                          ?                                                                                                                                                                                       4) PARTY WALLS TO EXTEND TO UNDERSIDE




                                                                                                                                                                                                   above EGL
            First Floor
                                                                                                                                                       10°                                                        OF ROOF SHEET FIRE PROOF MINERAL
                                                                                                                                                                                                                  WOOL OVER WHERE NOT PROTUDING
380




            5830
                                                                                                                                                                                                                  5) EXTERNAL BLOCK WALLS RENDERED &
                                                                                                                                                                                                                  PAINTED TO SELECTION WITH EXPRESSED
                                                                                                                                                                                                                  ARTICULATION JOINTS AS SHOWN
  frame

  ceiling




                                                                                                                                                                                                                  6) 10mm PLASTERBOARD LINING TO
   2750

   2700


joinery
 2400




                                                                                     LIVING              KITCHEN           STAIRS       GARAGE                                                                    INTERNAL 70/90mm STUD PARTITION WALLS
                                                                                                                                                                                                                  7) 10mm PLASTERBOARD LINING ON
                                                                                                                                                                                                                  28mm METAL BATTENS TO BLOCK WALLS
                                                                                                                                                                                                                  (NON PARTY WALLS)
            Ground Floor
300




            2700                                                                                                                                                                                                  8) COLORBOND CUSTOM ORB ROOFING
                                                                                                                                                                                                                  WITH 75 ANTICON BLANKET OR SIMILAR
            Flood Level
                                                                                                                                                                                                                  INSULATION TO SELECTION OVER METAL
            2400
                                                                                                                                                                                                                  PURLINS @900ctrs ON TIMBER TRUSSES TO
                      Concrete slab & footings to
                                                                                                                                                                                                                  MANUFACTURERS SPECIFICATIONS @
                      engineer's specifications                                                                                                                                                                   900ctrs WITH 10mm PLASTERBOARD
                                                                                                                                                             Existing Ground Line                                 CEILING TO 28mm METAL CEILING
                                                                          HOUSE 1 SECTION A-A                                                                                                                     BATTENS @450ctrs
                                                                      A   Scale: 1 : 100                                                                                                                          (NOTE: BATTENS MAY NEED TO BE
                                                                                                                                                                                                                  INSTALLED @450ctrs TO COMPLY WITH
                                                                                                                                                                                                                  WORKPLACE HEALTH & SAFETY
                                                                                                                                                                                                                  REQUIREMENTS IF NO OTHER METHOD OF
                                                                                                                                                                                                                  FALL ARREST IS ADDRESSED)

                                                                                                                                                                                                                  9) COLORBOND GUTTER AND DOWNPIPES
                                                                                                                                                                                                                  TO MATCH ROOFING TO SELECTION.
                                                                                                                                                                                                                  'OPTION' TIMBER OR COLORBOND FASCIA
                          Colorbond Custom Orb roof sheeting                                                                                                                                                      TO MATCH ROOFING
                          on trusses at 900crs
                                                                                                                                                                                                                  10) ALL JOINERY AT 2100/2400 HEAD
                          Prefabricated timber roof trusses                                                                                                                                                       HEIGHT (UNO) TO SELECTION
                          designed and installed to
                          manufacturer's specifications                                                                                                                                                           11) VERTICAL ALUMINIUM BLADE
                                                                                                                            15°                                                                                   SCREENING WITH FINISH TO CLIENT
                          Existing fascia and gutter made good                                                                                                                                                    SELECTION.
            Roof          and painted to selection
            8430                                                                                                                                                                                                  12) TREADS & RISERS TO COMPLY WITH
                          4.5mm FC soffit sheeting fixed to                                                                                                                                                       B.C.A. PART 3.9.1.4
                          38x50mm GOS H3 HWD battens                                                                                                                                                              BALUSTRADE & HANDRAILS TO COMPLY
                          Ceiling insulation as per energy report                                                                                                                                                 WITH B.C.A. PART 3.9.1.5
   frame

  ceiling
    2600

    2550


joinery




                          Insulation to all light weight clad walls
 2100




                                                                                                                                                                                                                  13) FULL TERMITE TREATMENT SYSTEM TO
                          as per energy report                                             BED 2     STUDY             BATH                                                                                       A.S. 3660 BY LICENCED INSTALLER
                                                                                                                                                                                                                  (SYSTEM TO PROVIDE 50 YEAR SERVICE
                                                                                                                                                                                                                  GUARANTEE)
            First Floor ?
380




            5830                                                                                                                                                                                                                                                                      SITE
                                                                                                                                                                                                                                       46-48 ELIZABETH STREET,
                                                                                                                                                                                                                                       NOOSAVILLE, QLD 4566
                          ?                                                                                                                                                                                                                                                     PROJECT
                                                                                                                                                                                                                             TOWNHOUSE DEVELOPMENT
  frame

 ceiling
   2750

   2700


joinery




                                                                      ALFRESCO              DINING               LIVING
 2400




                          Concrete slab & footings to                                                                                                                                                                                                                              CLIENT

                          engineer's specifications                                                                                                                                                                                           46 ELIZABETH Pty Ltd
                                                                                                                                                                                                                                                                        DRAWING TITLE
                                                                                                                                                                                                                                                 HOUSE 1 SECTIONS
            Ground Floor
300




            2700                                                                                                                                                                                                                        DESIGNED                                   SCALE

            Flood Level                                                                                                                                                                                                                  B.D.H.                                1 : 100
            2400                                                                                                                                                                                                                        CHECKED                          STAGE - ISSUE
                                                                                                                                                                                                                                         B.D.H.                             BA - 09
                                                              POOL                                                                                                                                                                         DRAWN                                    DATE
                                                                                                                                                                                                                                                 MJ                   15.10.2018
                                                                                                                                                                                                                                    PROJECT No.                                PAGE No.
                                                                                                                                                                                                                                         18070                         14 OF 84
                                                                                                                                                                                                                  0           1              2              3              4          5m


                                                                          HOUSE 1 SECTION B-B                                                                                                                     1: 100            1 3 0 0   1 3 3    9 1 7
                                                                      B   Scale: 1 : 100                                                                                                                                            [email protected]


                                                                                                                                    PRELIMINARY - NOT FOR CONSTRUCTION                                                                                           Q.B.C.C. 1029724
                                                                                                                                                                                                                                                                15/10/2018 3: 44: 41 PM

Used in these records

About this file

File size
4.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment A - Proposal plans.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.