Council archive · source document
Attachment A - Proposal plans · MCU17/0004.01
Attached to the e-mail Change to Development Approvals - MCU17/0004.01 & OPW17/0005.01.
Plans and drawings: the text below has words only, no drawings.
© COPYRIG HT | All rights reserved. This work is copyright and canot be
reproduced or use figured dimensionsions.
DO NOT SCALE check all dim ensions on site before fabrication or set out.
DO NOT COPY in any form or by me ans (graphic, electronic or mechanical,
includin g photocopying) without the written permision of Mercury Design.
SECTION NOTES
8m Above Existing Ground Line 1) CONCRETE SLAB, BLOCKWORK &
FOOTING DESIGN TO ENGINEERS
Colorbond Custom Orb roof sheeting
SPECIFICATIONS ON 0.2mm & 50mm
on trusses at 900crs Prefabricated timber roof trusses
MINIMUM SAND BEDDING
designed and installed to
Existing fascia and gutter made good 2) 200 SERIES BLOCKWORK CORE FILLED
manufacturer's specifications
and painted to selection AND REINFORCED TO ENGINEER'S
Roof SPECIFICATION
8430
? 4.5mm FC soffit sheeting fixed to 3) DISCONTINUOUS CONSTRUCTION TO
38x50mm GOS H3 HWD battens DETAIL WITH 1x13mm GYPROCK
Insulation to all light weight clad walls PLASTERBOARD CD & TSB4/ASB4
frame
ceiling
2600
2550
as per energy report
joinery
Privacy screen with 25% max visibilty POLYESTER BATTS AS PER ACCOUSTIC
WIR BED 1 STUDY BATH BED 3
2100
up to 1500mm min above FFL, refer REQUIREMENTS
? detail 4) PARTY WALLS TO EXTEND TO UNDERSIDE
OF ROOF SHEET FIRE PROOF MINERAL
First Floor WOOL OVER WHERE NOT PROTUDING
380
5830
5) EXTERNAL BLOCK WALLS RENDERED &
10mm Plasterboard lining to PAINTED TO SELECTION WITH EXPRESSED
battens fixed to frame 140x140 Dressed HWD timber posts, ARTICULATION JOINTS AS SHOWN
paint finish to selection
frame
ceiling
6) 10mm PLASTERBOARD LINING TO
2750
2700
joinery
GARAGE KITCHEN LIVING
2400
INTERNAL 70/90mm STUD PARTITION WALLS
Concrete slab & footings to 7) 10mm PLASTERBOARD LINING ON
28mm METAL BATTENS TO BLOCK WALLS
engineer's specifications
(NON PARTY WALLS)
Ground Floor
300
2700 8) COLORBOND CUSTOM ORB ROOFING
WITH 75 ANTICON BLANKET OR SIMILAR
Flood Level
INSULATION TO SELECTION OVER METAL
2400
PURLINS @900ctrs ON TIMBER TRUSSES TO
MANUFACTURERS SPECIFICATIONS @
900ctrs WITH 10mm PLASTERBOARD
Treated timber sleeper retaining wall
CEILING TO 28mm METAL CEILING
Existing Ground Line
HOUSE 3 SECTION A-A BATTENS @450ctrs
A Scale: 1 : 100
(NOTE: BATTENS MAY NEED TO BE
INSTALLED @450ctrs TO COMPLY WITH
WORKPLACE HEALTH & SAFETY
REQUIREMENTS IF NO OTHER METHOD OF
FALL ARREST IS ADDRESSED)
9) COLORBOND GUTTER AND DOWNPIPES
TO MATCH ROOFING TO SELECTION.
'OPTION' TIMBER OR COLORBOND FASCIA
TO MATCH ROOFING
Colorbond Custom Orb roof sheeting 10) ALL JOINERY AT 2100/2400 HEAD
on trusses at 900crs HEIGHT (UNO) TO SELECTION
Prefabricated timber roof trusses 11) VERTICAL ALUMINIUM BLADE
designed and installed to SCREENING WITH FINISH TO CLIENT
Ceiling insulation as per energy report SELECTION.
manufacturer's specifications
Roof
12) TREADS & RISERS TO COMPLY WITH
8430
B.C.A. PART 3.9.1.4
4.5mm FC soffit sheeting fixed to Insulation to all light weight clad walls BALUSTRADE & HANDRAILS TO COMPLY
38x50mm GOS H3 HWD battens as per energy report WITH B.C.A. PART 3.9.1.5
frame
ceiling
2600
2550
joinery
BATH STUDY BED 2
2100
13) FULL TERMITE TREATMENT SYSTEM TO
? A.S. 3660 BY LICENCED INSTALLER
7850 at ridge
(SYSTEM TO PROVIDE 50 YEAR SERVICE
above EGL
GUARANTEE)
First Floor
380
5830 SITE
46-48 ELIZABETH STREET,
140x140 Dressed HWD timber posts, NOOSAVILLE, QLD 4566
paint finish to selection PROJECT
TOWNHOUSE DEVELOPMENT
frame
ceiling
2750
1200mm high frameless glass pool
2700
joinery
2400
CLIENT
LIVING DINING ALFRESCO fence and gate in accordance with 46 ELIZABETH Pty Ltd
Concrete slab & footings to QBCC, QDC MP3.4 & A.S.1926
DRAWING TITLE
engineer's specifications
Pool to engineer's design HOUSE 3 SECTIONS
Ground Floor
300
2700 DESIGNED SCALE
B.D.H. 1 : 100
CHECKED STAGE - ISSUE
B.D.H. BA - 09
POOL DRAWN DATE
MJ 15.10.2018
PROJECT No. PAGE No.
18070 52 OF 84
0 1 2 3 4 5m
HOUSE 3 SECTION B-B
B Scale: 1 : 100
1: 100 1 3 0 0 1 3 3 9 1 7
[email protected]
PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
15/10/2018 3: 45: 27 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment A - Proposal plans.pdfRelated documentApplication case desk ↗
Attachment A - Proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.