Council archive · source document
Attachment A - Proposal plans · MCU17/0004.01
Attached to the e-mail Change to Development Approvals - MCU17/0004.01 & OPW17/0005.01.
Plans and drawings: the text below has words only, no drawings.
© COPYRIG HT | All rights reserved. This work is copyright and canot be
reproduced or use figured dimensionsions.
DO NOT SCALE check all dim ensions on site before fabrication or set out.
DO NOT COPY in any form or by me ans (graphic, electronic or mechanical,
includin g photocopying) without the written permision of Mercury Design.
Colorbond Custom Orb roof sheeting EXTERIOR FINISHES LEGEND
on trusses at 900crs CODE DESCRIPTION TYPE
ECL-01 10mm[nom] smooth cement render To client selection
Existing fascia and gutter made good finish + painted
and painted to selection ECL-02 10mm [nom] smooth render finish + To client selection
15° ERO-02 painted
Roof ECL-05 J. Hardie scyon Linea 180mm To client selection
8430 horizontal groove, painted
EDR-01 Pivot entrance door, painted To client selection
ECL -05 EDR-02 Garage door panel sectional, To client selection
2600
ESC-02 painted
Privacy screen with 25% max visibilty ESC-02
EDR-03 Garage roller door, painted To client selection
7670 at ridge
up to 1500mm min above FFL, refer
above EGL
EDR-04 Hinged external door, painted To client selection
detail
First Floor EFL-01 Metal roof flashing with Colorbond COLORBOND
5830 Monument finish FLASHING
EGA-01 Swing gate, vertical timber batten Sikkens cetol hls
42x42 walnut
Hardies Scyon Linea 180mm FC EJO-01 Aluminium joinery, powder coated to To client selection
cladding fixed to manuf's specs EDR-04 match Colorbond
2750
ERO-02 Colorbond Custom Orb roof sheeting To client selection
on trusses at 900crs
ESC-02 50x25 Horizontal batten privacy To client selection
screen, p/coated
Ground Floor ESS-01 316 Marine Grade Stainless Steel Handrails to
2700 selection
Flood Level
2400 ETP-01 140sq HWD timber post, painted To client selection
EGA-01
HOUSE 4 NORTH ELEVATION
1 Scale: 1 : 100
Colorbond Custom Orb roof sheeting
on trusses at 900crs
Existing fascia and gutter made good
15° and painted to selection
Roof
8430
Privacy screen with 25% max visibilty
up to 1500mm min above FFL, refer
detail
2600
ECL -05
ESC-02
Hardies Scyon Linea 180mm FC
cladding fixed to manuf's specs
First Floor ECL -05
5830 10° SITE
46-48 ELIZABETH STREET,
140x140 Dressed HWD timber posts, NOOSAVILLE, QLD 4566
1200mm high pool fence paint finish to selection PROJECT
and gate in accordance ETP-01 TOWNHOUSE DEVELOPMENT
2750
with QBCC, QDC MP3.4 & CLIENT
A.S.1926 46 ELIZABETH Pty Ltd
DRAWING TITLE
ECL -02 HOUSE 4 ELEVATIONS
Ground Floor
2700 DESIGNED SCALE
B.D.H. 1 : 100
CHECKED STAGE - ISSUE
B.D.H. BA - 09
Aluminium framed doors and windows DRAWN DATE
EDR-04 FC external cladding with installed to manufacturer's MJ 15.10.2018
render & paint finish specifications
HOUSE 4 EAST ELEVATION PROJECT No.
18070 69 OF 84
PAGE No.
2 Scale: 1 : 100 0 1 2 3 4 5m
1: 100 1 3 0 0 1 3 3 9 1 7
[email protected]
PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
15/10/2018 3: 45: 41 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment A - Proposal plans.pdfRelated documentApplication case desk ↗
Attachment A - Proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.