                                                                                                                                                                                                   SECTION NOTES
                                                                                                                                      8m Above Existing Ground Line
                                                                                                                                                                                                  1) CONCRETE SLAB, BLOCKWORK &
                                                                                                                                      Colorbond Custom Orb roof sheeting                          FOOTING DESIGN TO ENGINEERS
                                                                                                                                      on trusses at 900crs                                        SPECIFICATIONS ON 0.2mm & 50mm
                                                                                                                                                                                                  MINIMUM SAND BEDDING
                                                                                                                                      Prefabricated timber roof trusses
                   Ceiling insulation as per
                                                                                                                                      designed and installed to                                   2) 200 SERIES BLOCKWORK CORE FILLED
                   energy report
                                                                                                                                      manufacturer's specifications                               AND REINFORCED TO ENGINEER'S
            Roof                                                                                                                                                                                  SPECIFICATION
            8430                                                                                                                      Existing fascia and gutter made good
                   Insulation to all light weight                                                                                     and painted to selection                                    3) DISCONTINUOUS CONSTRUCTION TO
                   clad walls as per energy                                                                                                                                                       DETAIL WITH 1x13mm GYPROCK
                   report                                                                                                             4.5mm FC soffit sheeting fixed to                           PLASTERBOARD CD & TSB4/ASB4
   frame

  ceiling
    2600

    2550




                                                                                                                                      38x50mm GOS H3 HWD battens
joinery




                                                             WIR            BED 1           STUDY     BATH      BED 3                                                                             POLYESTER BATTS AS PER ACCOUSTIC
 2100




                    Colorbond Parapet
                                                                                                                                                                                                  REQUIREMENTS
                    Capping to match roof
                    colour                                                                                                            ?                                                           4) PARTY WALLS TO EXTEND TO UNDERSIDE
                                                                                                                                                                                                  OF ROOF SHEET FIRE PROOF MINERAL
            First Floor                                                                                                                                                                           WOOL OVER WHERE NOT PROTUDING
380




            5830
                                                                                                                                                                                                  5) EXTERNAL BLOCK WALLS RENDERED &
                   Blockwork wall to engineer's                                                                                       10mm Plasterboard lining to battens                         PAINTED TO SELECTION WITH EXPRESSED
                   design, Rendered &                                                                                                 fixed to frame                                              ARTICULATION JOINTS AS SHOWN
                   painted to selection
  frame

 ceiling




                                                                                                                                                                                                  6) 10mm PLASTERBOARD LINING TO
                                                                     GARAGE                    KITCHEN       DINING       PATIO
   2750

   2700


joinery




                                                                                                                                      10mm Plasterboard lining to stud frame
 2400




                                                                                                                                                                                                  INTERNAL 70/90mm STUD PARTITION WALLS
                                                                                                                                      to AS1684.2
                                                                                                                                                                                                  7) 10mm PLASTERBOARD LINING ON
                                                                                                                                      Concrete slab & footings to engineer's                      28mm METAL BATTENS TO BLOCK WALLS
                                                                                                                                      specifications                                              (NON PARTY WALLS)
            Ground Floor
300




            2700                                                                                                                                                                                  8) COLORBOND CUSTOM ORB ROOFING
                                                                                                                                                                                                  WITH 75 ANTICON BLANKET OR SIMILAR
            Flood Level
                                                                                                                                                                                                  INSULATION TO SELECTION OVER METAL
            2400
                                                                                                                                      Existing Ground Line                                        PURLINS @900ctrs ON TIMBER TRUSSES TO
                                                                                                                                                                                                  MANUFACTURERS SPECIFICATIONS @
                                                                                                                                                                                                  900ctrs WITH 10mm PLASTERBOARD
                                                         HOUSE 4 SECTION A-A                                                                                                                      CEILING TO 28mm METAL CEILING
                                                    A    Scale: 1 : 100
                                                                                                                                                                                                  BATTENS @450ctrs
                                                                                                                                                                                                  (NOTE: BATTENS MAY NEED TO BE
                                                                                                                                                                                                  INSTALLED @450ctrs TO COMPLY WITH
                                                                                                                                                                                                  WORKPLACE HEALTH & SAFETY
                                                                                                                                                                                                  REQUIREMENTS IF NO OTHER METHOD OF
                                                                                                                                                                                                  FALL ARREST IS ADDRESSED)

                                                                                                                                                                                                  9) COLORBOND GUTTER AND DOWNPIPES
                                                                                                                                                                                                  TO MATCH ROOFING TO SELECTION.
                                                                                                                                                                                                  'OPTION' TIMBER OR COLORBOND FASCIA
                                                                                                                                      Colorbond Custom Orb roof sheeting
                                                                                                                                                                                                  TO MATCH ROOFING
                                                                                                                                      on trusses at 900crs
                                                                                                                                                                                                  10) ALL JOINERY AT 2100/2400 HEAD
                                                                                                                                      Prefabricated timber roof trusses                           HEIGHT (UNO) TO SELECTION
                                                                                                                                      designed and installed to
                                                                                                                                      manufacturer's specifications                               11) VERTICAL ALUMINIUM BLADE
                                                                                                                                                                                                  SCREENING WITH FINISH TO CLIENT
                                                                                                                                      Existing fascia and gutter made good                        SELECTION.
            Roof                                                                                                                      and painted to selection
                                                                                                                                                                                                  12) TREADS & RISERS TO COMPLY WITH
            8430
                                                                                                                                      4.5mm FC soffit sheeting fixed to                           B.C.A. PART 3.9.1.4
                                                                                                                                      38x50mm GOS H3 HWD battens                                  BALUSTRADE & HANDRAILS TO COMPLY
                                                                                                                                                                                                  WITH B.C.A. PART 3.9.1.5
   frame

  ceiling




                                                                                                                                      Insulation to all light weight clad walls
    2600

    2550




                                                                                     BATH           STUDY    BED 2
joinery
 2100




                                                                                                                                      as per energy report                                        13) FULL TERMITE TREATMENT SYSTEM TO
                                                                                                                                                                                                  A.S. 3660 BY LICENCED INSTALLER




                                                                                                                                                                                  7670 at ridge
                                                                                                                                                                                   above EGL
                                                                                                                                                                                                  (SYSTEM TO PROVIDE 50 YEAR SERVICE
                                                                                                                                  ?
                                                                                                                                                                                                  GUARANTEE)
            First Floor
380




            5830                                                                                                                                                                                                                                                      SITE
                                                                                                                                                                                                                       46-48 ELIZABETH STREET,
                                                                                                                                      10mm Plasterboard lining to battens                                              NOOSAVILLE, QLD 4566
                                                                                                                                      fixed to frame                                                                                                            PROJECT
                                                                                                                                                                                                             TOWNHOUSE DEVELOPMENT
  frame

 ceiling
   2750

   2700


joinery




                                                                                                                                      ?
 2400




                                                                          ALFRESCO      DINING               LIVING                                                                                                           46 ELIZABETH Pty Ltd
                                                                                                                                                                                                                                                                   CLIENT



                                                                                                                                      Concrete slab & footings to engineer's                                                                            DRAWING TITLE
                                                                                                                                      specifications                                                                             HOUSE 4 SECTIONS
            Ground Floor
300




            2700                                                                                                                                                                                                        DESIGNED                                   SCALE
            Flood Level                                                                                                                                                                                                  B.D.H.                                1 : 100
            2400                                                                                                                                                                                                        CHECKED                          STAGE - ISSUE
                                                        POOL                                                                                                                                                             B.D.H.                             BA - 09
                                                                                                                                                                                                                           DRAWN                                    DATE
                   Pool to engineer's design                                                                                                                                                                                     MJ                   15.10.2018
                                                                                                                                                                                                                    PROJECT No.                                PAGE No.
                                                                                                                                                                                                                         18070                         71 OF 84
                                                                                                                                                                                                  0           1              2              3              4          5m


                                                         HOUSE 4 SECTION B-B                                                                                                                      1: 100
                                                    B    Scale: 1 : 100
                                                                                                                                                                                                                    1 3 0 0   1 3 3    9 1 7
                                                                                                                                                                                                                    [email protected]


                                                                                                                      PRELIMINARY - NOT FOR CONSTRUCTION                                                                                         Q.B.C.C. 1029724
                                                                                                                                                                                                                                                15/10/2018 3: 45: 50 PM

Used in these records

About this file

File size
4.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment A - Proposal plans.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.