Re: Application for Operational Works - Landscaping, Stormwater, Silt &
Sediment Control, Driveway & Parking situated at 74 Peregian Esplanade
Peregian Beach described as Lot 351 on P93114
I refer to the above and advise that following preliminary examination of the application,
the following information is required to be submitted:-
Land Use
1. Please provide a Landscaping Plan in accordance with Council’s Landscaping
Policy and the Landscaping Code of The Noosa Plan.
Land Development
2. Please provide a plan indicating the proposed sediment and erosion controls
measures to be employed on site.
Access
3. Please provide a plan indicating the extent of batters in the road reserve required
for the access driveway.
Stormwater
4. Please provide additional detail on the proposed stormwater storage/reuse tanks.
5. Please indicate on the plans the invert levels of all pits and pipework.
6. Please provide additional detail on the proposed outlet headwalls.
7. Include a management and maintenance plan for the gross pollutant traps.
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
8. Please provide certification from the design engineer that the stormwater
drainage system is in accordance with Noosa Planning Scheme Policy 5 -
Engineering Design Standards – Roads, Drainage and Earthworks.
It is noted that Council has not yet decided the MCU application (06/0273) for the
proposed development. Further information and / or amended plans may be required
upon deciding the MCU application.
Please provide (4) copies of all information that you are providing.
Pursuant to the conditions of the Material Change of Use of Premises please note that
all bonds and contributions are required to be paid prior to the issue of the Operational
Works approval.
Please be aware that under Section 3.2.12 of the Integrated Planning Act, the applicant
is to respond to any information request within 12 months of the request or otherwise,
the application lapses.
Under the provisions of the Integrated Planning Act 1997, you as the applicant, have
three options available in response to this Information Request. You may give the
assessment manager (in this instance Council) and each referral agency (if any):-
1. all of the information requested; or
2. part of the information requested together with a letter asking the assessment
manager and each referral agency to proceed with the assessment of the
application; or
3. a letter:-
3.1. stating that you do not intend to supply any of the information requested;
and
3.2. asking the assessment manager and each referral agency to proceed with
the assessment of the application.
The above information is required to be submitted, prior to assessment of the
application. If any further matters arise as part of assessment of this application, you
will be advised accordingly.
Should you have any further queries in relation to the above, please do not hesitate to
contact me on the above number.
Yours faithfully,
Nick Cooper
PLANNING OFFICER
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
Used in these records
Request for Further Information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 9 KB (small file)
- File type
No other editions are linked here.