Council archive · source document
Approved Plan - MCU23 003802 (As Published) · MCU23/0038.02
Plans and drawings: the text below has words only, no drawings.
NOTES
1. Figured dimensions take precedence over scaled.
2. Figured dimensions are millimetres unless noted otherwise.
3. Check all dimensions on site prior to commencement of work.
4. These designs, drawings and specifications, and copyright
thereof, are the property of Wilson Architects Pty. Ltd. and must
4m 3m Proposed Pad Council annotation: not be used, retained or copied without the written authority of
Wilson Architects Pty Ltd.
1m Proposed Transformer
2.5m
4 containers used for Storage and
12,287
Shed 2 1 workshop areas.
10
3 2.5
4,800
4
,00
0
2,000
10,000 2,290
12.5m 5,700 Approx
Relocated existing hydrant
Approx 565
1
600
Council annotation:
gin
Envirotec Horticultural building to be
ild
bu
of
r
3No. Additional Carparks
rne
co
00 used for Storage and workshop areas.
m
fro
,7
10
ce
an
ar
c le
2.5m
um
Ex FH
nim
ACTION STREET
Mi
(to be removed)
5.5m
60m
Z
EXISTING HARDSTAND
ACTION STREET
Emt H
MCH811938
290 A BACKGROUND ISSUE FOR HYDRANT COVERAGE 7/2/22
MCH811938 EXISTING BUILDING B
C
Hydrant Amendments
Dimensions Added
9/3/22
26/4/22
D Transformer Added 27/4/22
X External Plant added 2/6/22
Y New Stair 7/7/22
Z Revised External Plant 14/7/22
Awning Over
Rev Revision Description Date Ver
Architect
4,200
900
2,700
New Fire Hydrant
New Shield wall to comply
C6 with AS2419.1-2005
(3200h AGL)
Client
C5 Provectus Algae
Council annotation:
C4 6 containers used for Storage and
Project
C3 workshop areas. Provectus Algae Scale up
Facility
C2
Title
C1
SITE PLAN
Plot Date 14/7/22 Drwn Chck
Project No. Scale
5779 1:200 at A1
Drawing No. Revision
NOOSA COUNCIL
APPROVED PLAN CD-A-100 Z
MCU23/0038.02 1 APRIL 2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 5 pages
Page 2
7 Cal pro 6 Gra RM 3 Cal pro 3 Cal pro 3 Cal pro 6 Gra RM 7 Cal pro
4 Gre GL 9 CAL WW 27 Cal LJ 5 Gre GL 27 Cal LJ 9 CAL WW 4 Gre GL EXISTING LANDSCAPE
98670
0o0'0" 98.670
6006
61.220
90o0'0"
75.810
270o0'0"
EXISTING APPROVED BUILDING
APPLICATION No: MCU 23/0038
180o0'0" 47.670
B 07.11.23 Landscape notes amended ST DJ
A 07.11.23 MCU Application Issue ST DJ
14.500
JENNIFER HAWKER
A C T I O N S T R E E T
90o0'0"
16-14 Action St, (LOT 290)
Noosaville
PROPOSED LANDSCAPE PLAN
NOOSA COUNCIL
ST DJ
0o0'0" 51.000 APPROVED PLAN 06.11.23
02 SITE PLAN MCU23/0038.01 8 DECEMBER 2023
As Indicated
2023-47 02
- LEVEL 1 Scale 1:300 @ A3
NOTE: Scale Shown for A3 Drawing WORKING DRAWINGS B
GSPublisherVersion 2666.0.1.19
Document Set ID: 22732467
Version: 1, Version Date: 14/12/2023
Page 3
LANDSCAPE NOTES
LARGE SHRUBS
PREPARATION OF GARDEN BEDS FOR PLANTING
CULTIVATE EXISTING SOIL IN NATURAL GROUND TO A MINIMUM
DEPTH
OF 150mm. IMPORT CLEAN TOPSOIL (SANDY LOAM) TO A MINIMUM
DEPTH OF 300mm, ABOVE ORIGINAL GROUND LEVEL. ORGANIC
MATTER OR GYPSUM ETC, MAY ALSO BE ADDED SOIL FOR THE
BEST POSSIBLE GROWTH TEST THE SOIL USING A 'SOIL TEST KIT'
TO ENSURE IT IS HEALTHY AND AMEND AS NECESSARY.
ALL GARDEN BEDS TO BE MOUNDED 300mm MIN AT CENTRE OF
BED, ABOVE FINISHED PAVEMENT LEVELS, TO PREVENT ANY
PONDING AROUND PLANTS.
FERTILIZE USING A SLOW RELEASE FERTILIZER IN 'PILL' OR
'GRANULE' FORM, AT TIME OF PLANTING. ENSURE THAT CALLISTEMON viminalis CALLISTEMON viminalis
FERTILIZER DOES NOT DIRECTLY CONTACT ROOTS. "Prolific" "Wilderness White"
INSTALL AN AUTOMATIC IRRIGATION SYSTEM WITH TIMER. PLACE
IRRIGATION LINE AFTER PLANTING & PRIOR TO MULCHING.
SMALL SHRUBS
USE ONLY SUN 'HARDENED' PLANTS. ENSURE HEALTHY ROOT
SYSTEM TO ALL PLANTS TO BE USED. UNDER NO
CIRCUMSTANCES ARE ROOT BOUND
PLANTS TO BE USED.
MULCH
ALL GARDENS ARE BE MULCHED WITH 'TEA TREE' MULCH TO A
MINIMUM DEPTH OF 100mm.
DRAINAGE
PLEASE ENSURE ADEQUATE DRAINAGE IS INSTALLED BELOW
GARDENS AND PAVED AND CONCRETED AREAS. Callistemon 'Little John' GREVILLEA
"Golden Lyre"
LOCATION OF SERVICES AND LEVELS:
GROUND COVERS
PLEASE REFER HYDRAULICS PLAN FOR FULL INFORMATION ON
SERVICES TYPE AND LOCATION AND FINISHED LEVELS.
MAINTENANCE:
IT IS THE RESPONSIBILITY OF THE PROPERTY OWNER TO
MAINTAIN THE PROPERTY TO A SATISFACTORY STANDARD TO
COUNCIL'S APPROVAL.
A MAINTENANCE REGIME MUST BE PROGRAMMED TO MAINTAIN
MULCH, WATER, FERTILIZER, PRUNING AND THE CARE AND/OR
REPLACEMENT OF ANY DAMAGED OR DISEASED PLANT.
SHORT TERM
FOR THE FIRST 4 WEEKS ALL PLANTS MUST BE WATERED FOR
20mins PER DAY min. REDUCING TO 10mins PER DAY FOR GREVILLEA
FOLLOWING 5 MONTHS, (ALWAYS WATER IN RELATION TO "Royal Mantle"
RAINFALL).
LONG TERM
FERTILIZE ALL PLANTS EACH SPRING & WHEN REQUIRED DURING
THE YEAR. ENSURE USE OF A NATIVE 'FRIENDLY' FERTILIZER.
TREES & SHRUBS TO BE PRUNED AFTER FLOWERING TO MAINTAIN
HEALTHY GROWTH AND SHAPE. PRUNE AT THE NODE FOR ALL
NATIVES. NEVER 'HARD PRUNE' A PLANT UNLESS ON RELIABLE
AUTHORITY.
DUE TO BREAKING DOWN, ORGANIC MULCH NEEDS TO BE
'TOPPED UP' EVERY FEW YEARS TO MAINTAIN A THICK COVER.
STAKES AND WEBBING WHICH SUPPORT TREES MAY BE REMOVED NO: CODE BOTANICAL NAME COMMON NAME HEIGHT SPREAD COLOUR POT SIZE
AFTER TREES ARE SUITABLY ESTABLISHED.
LARGE SHRUBS
29 Cal pro CALLISTEMON viminalis "Prolific" Weeping Bottlebrush 6m 3m Red 25L
SMALL SHRUBS
54 Cal LJ Callistemon 'Little John' Little John 1m 1m Red 140mm
13 Gre GL Grevillea spp. "Golden Lyre" 1m 5m Yellow 140mm
B 07.11.23 Landscape notes amended ST DJ
A 07.11.23 MCU Application Issue ST DJ
18 Cal WW Callistemon viminalis "Wilderness White" 3m 2m White 200mm
GROUND COVERS
JENNIFER HAWKER
12 Gre RM Grevillea spp. "Royal Mantle" 0.5m 5m Burgundy 140mm
16-14 Action St, (LOT 290)
Noosaville
LANDSCAPE SCHEDULE
NOOSA COUNCIL
ST DJ
APPROVED PLAN As Indicated 06.11.23
MCU23/0038.01 8 DECEMBER 2023 2023-47 03
NOTE: Scale Shown for A3 Drawing WORKING DRAWINGS B
GSPublisherVersion 2666.0.1.19
Document Set ID: 22732467
Version: 1, Version Date: 14/12/2023
Page 4
1 2 3 4 5 6
A A
12000
12233
7349 APPROX
B B
4000
50 100
2400 2350 2500 2350 2400
63403 OVERALL
A ( 1 : 150 )
C C
A
2500 CRS
30000
NOOSA COUNCIL 62550 OUTSIDE OF POSTS
APPROVED PLAN
MCU23/0038.02 1 APRIL 2026
Envirotec Horticultural Structures ©THIS DRAWING AND ANY Provectus Algae
PROJECT CLIENT:
12.1m x 62.55m Vertical Wall
D 31-35 Paulger Flat Rd DESIGN ENGINEERING AND
CERTIFICATIONS REMAIN
Tunnelhouse D
PROJECT ADDRESS:
CLIENT APPROVAL Yandina Qld 4561 PROPERTY OF ENVIROTEC
HORTICULTURAL STRUCTURES
General Arrangement
ABN: 67 160 113 922 AND MUST NOT BE REPRODUCED
P: 1800 672 794 IN PART OR WHOLE WITHOUT
DRAWING NO REVISION REVISION DATE
PRIOR WRITTEN CONSENT OF
E: [email protected] ENVIROTEC HORTICULTURAL PROJECT # PRO2938 0
STRUCTURES. DRAWN: KS DATE: 3/09/25 SCALE 1 : 250 PAGE 2 OF 3
1 2 3 4 5 6
Page 5
IF IN DOUBT, ASK.
DO NOT SCALE THIS DRAWING. USE FIGURED DIMENSIONS ONLY. ALL DIMENSIONS TO BE VERIFIED ON SITE.
2 2
2 7
9000 (SIDEWALL)
4500 4500
1 2
C1 C2 C1
3
3000
6000 (ENDWALL)
ROOF FALL
4 4 1 3 3
7 C3 2 3 2 C3 7
DK3
DK1
5 4
3000
Y
4
C1 C4 C1
6 7
1 1
2 7
1 FOUNDATION PLAN AND MEMBER LAYOUT
1 SCALE: 1 = 100
NOOSA COUNCIL
APPROVED PLAN MEMBER LEGEND
MCU23/0038.02 1 APRIL 2026 C1 C15019
C2 2C15024
ROOF STRAP BRACING TO BE CONNECTED TO THE PURLIN CLOSEST TO THE LINE OF THE END WALL MULLION C3 C15012
ROOF STRAP BRACING CAN BE PLACED FROM EITHER END OF THE BUILDING PROVIDING THE STRAP PATTERN REMAINS AS PER PLANS C4 2C15019
STEEL BUILDING BY (CONTACT) Mr Timothy Roy Messer BE MIEAust RPEQ
Civil & Structural Engineers
JUST SHEDS SUNSHINE COAST & GYMPIE
1
50 Punari Street
CSTS66660
Currajong, Qld 4812
23/9/2025
FOR 07 5445 8532 Fax: 07 4725 5850 Signature ............................................................
STR
TM
AT
ENAYET KHAN Email: [email protected]
ABN 341 008 173 56 Date ......................................
23/9/2025
7
Registered Chartered Professional Engineer Regn. No. 2558980
Registered on the NPER in the areas of practice
14-16 ACTION ST, Registered Professional Engineer (Civil & Structural) QLD
Registered Certifying Engineer (Structural) N.T.
Regn. No. 9985
Regn. No. 116373ES of Civil & Structural National Professional
NOOSAVILLE Registered Engineer - (Civil) VIC
Registered Engineer - (Civil) TAS
Regn. No. PE0002216
Regn. No. CC5648M Engineers Register
Document Set ID: 24295896
Version: 1, Version Date: 12/11/2025
Page 6
ROOF PURLINS PER
MEMBER SCHEDULE ON
SHEET 5
6 7 2 1
1 SIDEWALL EXTERIOR ELEVATION 2 SIDEWALL EXTERIOR ELEVATION
2 SCALE: 1 = 100 2 SCALE: 1 = 100
ROOF PURLINS
PER SCHEDULE
ROOF PURLINS
PER SCHEDULE
DK2
C TO PEAK C TO PEAK
5 5
525
TO EAVE
3525
3525
3000
5 4
E E 3
5 5
T.O. CONCRETE T.O. CONCRETE
NOOSA COUNCIL
APPROVED PLAN
MCU23/0038.02 1 APRIL 2026
4 ENDWALL INTERIOR ELEVATION 3 ENDWALL INTERIOR ELEVATION
2 SCALE: 1 = 100 2 SCALE: 1 = 100
X BRACING IS REQUIRED IN 1 SIDE BAY, 1 END BAY, 1 ROOF BAY.
SEE LAYOUT OR PLANS FOR PLACEMENT. FLY BRACING IS INCLUDED TO BE PLACED ON EVERY SECOND PURLIN AND GIRT ON ENDWALL MULLIONS, INTERNAL COLUMNS AND INTERNAL RAFTERS.
STEEL BUILDING BY (CONTACT) Mr Timothy Roy Messer BE MIEAust RPEQ
Civil & Structural Engineers
JUST SHEDS SUNSHINE COAST & GYMPIE
2
50 Punari Street
CSTS66660
Currajong, Qld 4812
23/9/2025
FOR 07 5445 8532 Fax: 07 4725 5850 Signature ............................................................
STR
TM
AT
ENAYET KHAN Email: [email protected]
ABN 341 008 173 56 Date ......................................
23/9/2025
7
Registered Chartered Professional Engineer Regn. No. 2558980
Registered on the NPER in the areas of practice
14-16 ACTION ST, Registered Professional Engineer (Civil & Structural) QLD
Registered Certifying Engineer (Structural) N.T.
Regn. No. 9985
Regn. No. 116373ES of Civil & Structural National Professional
NOOSAVILLE Registered Engineer - (Civil) VIC
Registered Engineer - (Civil) TAS
Regn. No. PE0002216
Regn. No. CC5648M Engineers Register
Document Set ID: 24295896
Version: 1, Version Date: 12/11/2025
Used in these records
Approved Plan - MCU23 003802 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.