                Determining the Radius of the TPZ (Tree Protection Zone)
                ·   DBH (Diameter at Breast Height) - nominal trunk diameter at 1.4m above ground level
                ·   TPZ should not be less than 2m nor greater than 15m (except where crown protection is required)
                ·   TPZ = DBH X 12
                ·   TPZ of palms, other monocots, cycads and tree ferns should not be less than 1m
                ·   Variations and encroachments to the TPZ in accordance with AS 4970-2009.




                                                                                                     Fluorescent orange 5.5k.g
                                                                                                     barrier fencing mesh secured
                                                                                                     / tied 100mm below top of star                                                                                                                                                                              Plant pit 2x width of respective pot.                 2x pot Ø
                                                 Measurement                                                                                                                                                                                                                                                                                                                      Shrub / groundcover / tufty
                                                                                                     pickets at 300mm centres                                                                                                                                                                                    Scarify all pit walls and bottom, typ.
                                                 taken for DBH                                                                                                                                                                                                                                                                                                                    grass plant species per plan
                                                                                                    Yellow plastic capped                                                                                                                                                                                                                                               Pot Ø
                                                     Fencing
                                                                                                    star pickets
                                                                                                    painted yellow                                                                                                                                                                                               Backfill plant pit with specified                                100mm deep and settled organic
                                                Vegetation to                      1200mm
                                   1.4m




                                                                                                                                                                                                                                                                                                                 topsoil, avoid compaction, typ.                                  mulch as specified, keep minimum
                                                be protected
                                                                                                                                                                                                                                                                                                                                                                                  50mm from plant stem. Form shallow
                                                                                                         Ground line                                                                                                                                                                                                                                                              dish drain to base of plant, typ.
                           Crown               DBH                                                                                                                                                                                                                                                               Garden topsoil as specified,
                                                                                    600mm
                           TPZ                                                                                                                                                                                                                                                                                   avoid compaction, typ.

                  NOTES:
                                                                                                                                                                                                                                                                                                                 100mm, typ.
                  ·  Protective fencing to be installed around the TPZ to the commencement of any site works.
                  ·  Protective fencing identifying the TPZ, to be visibly signed within the development site. Lettering to comply with AS1319.                                                                                                                                                                                                                                   Slow release fertiliser as specified.
                  ·  Fence posts and supports to have a diameter greater than 20mm, located clear of roots                                                                                                                                                                                                       2x rootball depth, typ.                                          Use phosphorus free tablets for
                  ·  Where tree protection fencing cannot be installed, trunk, branch and ground protection as specified by the project                                                                                                                                                                                                                                           Banksia, Callistemon and Grevillea
                     Arborist in accordance with AS4970-2009                                                                                                                                                                                                                                                                                                                      species.
                  ·  Within TPZ, mulch to a depth of 50-100mm only for disturbed land                                                                                                                                                                                                                                                                                             150mm deep cultivated
                                                                                                                                                                                                                                                                                                                 150mm, typ.
                  ·  Maintenance of TPZ includes regular monitoring of soil moisture levels and weed removal by hand and controlled by                                                                                                                                                                                                                                            subgrade, typ.
                     appropriate use of herbicide
                  ·  TPZs to be monitored, inspected and certified by the project Arborist                                                                                                                                                                                                                       Existing subgrade, typ.
                  ·  Removal of tree protection measures at practical completion or as indicated by the project Arborist.


                     1             Tree and Vegetation Protection Detail                                                              N.T.S.                                                                                                                                                                         4         Potted Shrub, Groundcover Planting
                   LD3             Typical Detail                                                                                                                                                                                                                                                                  LD3         Typical Section Detail                                                            N.T.S.




                                                                                                                                                  NOTES:
                                                                                                                                                  Ensure crown of rootball level is set higher than adjacent finished ground levels to prevent excessive ponding around rootball.
                                                                                                                                                  When footpath is adjacent to street tree install root barrier to footpath side of plant pit as per notes above.

                                                                                                                                                                                                        1800


                                                                                                                                                                                                                                                     Full and even crown, typical
                                                                                                                                                                                                                                                     2 - 50mm x 50mm x 2400mm F14 hardwood
                                                                                                                                                                                                                                                     centrally pointed non-treated stakes to be
                                                                                                                                                                                                                                                     driven vertically into ground outside of the
                                                                                                                                                  50mm wide hessian tree ties                                                                        rootball and shall have a finished height lower
                                                                                                                                                  wrapped loosely around trunk,                                                                      than the tree's lower lateral limbs
                                                                                                                                                  then a figure 8 and secured to
                                                                                                                                                  stake with galvanised nails or                                                                     Form shallow saucer shaped depression                                                                                                                                                                600mm
                                                                                                                                                  staples. Position tree tie between                                                                                                                                                                                                                                                                      typical
                                                                                                                                                                                                                                                     around base of plant and keep mulch 50mm
                                                                                                                                                  1/3 to 1/2 overall height of tree.
                                                                                                                                                                                                                                                     from trunk base

                                                                                                                                                                                                                                                     100mm deep organic mulch as specified.
                                                                                                                                                                                                                                                     Mound mulch at edge of plant pit to collect
                                                                                                                                                                                                                                                     water to fall down edges of plant pit.                                                                                                                                                              Varies,
                                                                                                                                                                                                                                                                                                                                                                                                                                                         refer
                                             Turf as specified                                                                                                                                                                                       Turf as specified                                                                                                                                                                                   Plans

                                             150mm Topsoil as specified
                                             Metal Edging as specified
                                                                                                                                                                                                                                                     Tree pit to be excavated to nominal depth of
                                                                                                                                                                                                                                                     600mm. Backfill hole with 100% friable
                                                                                                                                                  Slow release fertilizer                                                                            ameliorated site topsoil firming progressively.
                                             100mm mulch as specified                                                                             as specified                                                                                       All excavated fill to be removed off site. Scarify
                                             Tapered Edging Stake as specified                                                                                                                                                                       all sides of plant pit, typical.
                                             300mm Topsoil as specified
                                                                                                                                                                                                                                                     100mm deep uniform gravel layer. Provide
                                             150mm cultivated subgrade, typ.
                                                                                                                                                                                                                                                     clean connection to road drainage as advised
                                             Existing subgrade                                                                                                                                                                                       on site by civil engineer.                                                       Road                                         Back of kerb or hardstand              Turf Roll, typical


                    2          Metal Garden Edge                          N.T.S.                                                                      3           Tree Planting - in Garden or Turf                                                                                             1:30                  5           Turfing
                   LD3          Typical Detail                                                                                                       LD3          Typical Section                                                                                                                                   LD3           Typical Plan Detail                                                                                                     N.T.S.




                                                                                                                                                                                       NOTES:
                                                                                                                                                                                       This plan is Copyrighted © by Bird Landscape Design (Brian Bird - AILA RLA #1736).
                                                                                                                                                                                                                                                                                         Landscape Operational Works Package                         Project:                                                    BIRD LANDSCAPE DESIGN
                                                                                                                                                                                       Any reproduction or unauthorized use without written consent from                                 Job No: 2276                                                Proposed Duplexes                                           Landscape Architecture, Urban Design, Land Planning
                                                                                                                                                                                       Bird Landscape Design is strictly prohibited.                                                                                                                 7 Ruby Street, Cooroy, QLD                                  3 Vector Place, Little Mountain, QLD 4551 Australia
                                                                                                                                                                                       Do not scale from PDF plans.                                                                                                                                                                                              M: +614 7705 5222
                                                                                                                                                                                       All dimensions in millimetres unless noted otherwise.
                                                                                                                                                                                                                                                                                         LD3           Details                                                                                                   E: [email protected]
09.08.22   A     For Application                                                         BB         BB
                                                                                                                                                                                                                                                                                         Sheet Title                         Sheet 3 of 4            Client: Robyn Kildey                                        W: birdgolfdesign.com
DATE       ISSUE DESCRIPTION                                                             DRAWN CKD

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Landscape plan7 Ruby St BLD OW-A.pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.