Council archive · source document
Appendix A - Architectural Plans · 51901.3623.01
Plans and drawings: the text below has words only, no drawings.
KEY NOTES
1 EXISTING DOORS & WINDOWS REMOVED &
REPLACED WITH NEW. JAMBS ADJUSTED / CUT /
MADE GOOD AS REQUIRED
2 PERGOLA - NEW HIGH-QUALITY POLYCARB
SHEETING ON STAINED HWD & STEEL ROOF
STRUCTURE WITH STAINED BETTEN SOFFIT
(THIS PERGOLA TO REPLACE ORIGINAL
SLATTED PERGOLA FROM ORIGINAL
CONSTRUCTION). EXISTING ROOF FASCIA TO
BE CUT BACK BY 600mm WITH NEW FASCIA &
5 GUTTER
NOTE: RED DASHED LINES INDICATES 3 NEW PASSAGEWAY CUT THROUGH EXISTING
EXISTING STRUCTURE, FIXTURES AND DP DUCT. NEW FLOOR ADDED IF SLAB DOES NOT
FITTINGS TO BE REMOVED 4 4 CONTINUE
AC
SCREEN
2 4 NEW TILING OVER NEW WP MEMBRANE TO FALL
BALCONY 6 TO RECESSED GUTTER TO DP
AC 5 NEW GLASS BALUSTRADE WITH FRAMED TOP
1 1 1 DP RAIL. MAKE GOOD TO WALL SUPPORT
6 NEW TRAVERTINE FLOOR TILING
1 7 SOLID BALUSTRADE TO HALLWAY OPENING
AC AIRCON UNIT
2
C CUPBOARD JOINERY SELECTED FINISH
2
BED 1 ENS 2 BED 2 LIVING DP DOWNPIPE
R ROBE JOINERY SELECTED FINISH
6 6
SCREEN HARDWOOD BATTENS ON ALUM FRAMED
SCREEN
1 6 5
1
207
BALCONY
1 4
7
R LDY 6
1 ENS 1 6
1 3
206
CL
ENTRY
ENS 4 C 2
UP
1
205
1 BALCONY
6
PDR 1 5
4
BED 4 ENS 3 BED 3
1
6 6
R
SCREEN
1 1 1 DP
F:\Dropbox\Dropbox Projects\1. Bock Architecture\1201 Unit 7 & 8 Cove Point\1201 UNIT 7 8 WD.rvt
LEVEL 4 PROPOSED & DEMOLITION
1 1 : 100
REFER TO DRAWINGS WD101, WD102 & WD 103 FOR
1:50 VERSIONS OF THESE PLANS BC ISSUE
PROJECT CLIENT REV DATE DESCRIPTION SPECIFICATION NOTES SCALE PROJECT No DRAWING TITLE
PLOT DATE
1 5/10/21 ISSUED FOR BC APPROVAL 16/12/2021
PROPOSED UNIT HELEN & JOHN
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED READINGS
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE COMMENCING 1 : 100 1201 UNITS 7 & 8 PROPOSED FLOOR 15:11:26
2 16-12-21 ISSUED FOR BC APPROVAL FABRICATION
WOELDERS
ALTERATIONS 3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, RELEVANT
S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
PLAN WITH DEMOLITION
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF HINGES TO SHEET SIZE DRAWING No REVISION
7 & 8/18 PARK RD, NOOSA HEADS ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF CONSTRUCTION
L7 & L8 BUP4736 6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR USED
WITHOUT THE CONSENT OF THE AUTHOR. A3 DRAWN
1201 WD 003 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix A - Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.1 MB (small file)
- File type
No other editions are linked here.