1998 1150 ROOF NOTES
ABBREVIATION LEGEND CONTRACTOR TO PROVIDE ALL FLASHING,
COL-ex EXISTING 200MM DIAM. COLUMN FASCIA, EAVES, FIXINGS ETC TO ENSURE
UP AC LINE OF ROOF OVER
COL NEW COLUMN TO MATCH EXISTING COMPLETE WATERPROOFING AND
BATTEN SCREEN - GU NEW QUAD GUTTER PROFILE TO MATCH INSTALLED IN ACCORDANCE WITH THE
50x50MM ALUMINIUM SHS
EXISTING. COLOUR TO MATCH EXISTING. MANUFACTURER'S SPECIFICATIONS, M Design
D L
@ 30MM SPACINGS FIXED
O
built in desk
P
PO Box 290
C
TO ALUMINIUM TOP & DP-ex DOWNPIPE EXISTING INCLUDING ALL FASTENERS, EXPANSION
BOTTOM PLATE TO DECK & DP 90MM DIAM. DOWNPIPES,CONTRACTOR Peregian Beach QLD 4573
JOINTS, GASKETS, TRIMS, AND THE LIKE.
EAVE.
TO CONNECT INTO EXISTING STORM QBCC No. 1066058
SHEET METAL ROOFING: TO AS 1562.1.
WATER AS PER COUNCIL CORROSION PROTECTION TO NCC TABLE Contact: Michael Broeren
LINE OF ROOF OVER
REQUIREMENTS. 3.5.1.1.A. t. 07 5471 2721
NORTH BOUNDARY
LIVING ROOM BC BARGE CAPPING. TYPE AND COLOUR TO
TRIMDEK ROOF CLADDING FIXED TO
t. 0422 969 645
FFL approx.105.00 MATCH EXISTING. w. www.mdesign.com.au
CL approx. 2700 MANUFACTURE'S SPECIFICATIONS.
DECK RS ROOF SHEETING. COLORBOND TRIMDEK
PROVIDE ROOF INSULATION TO MEET MIN 6
TO MATCH EXISTING TYPE AND COLOUR.
STAR RATING. INSTALL TO
OH OVERHANG
MANUFACTURER'S SPECIFICAITONS
100
C.O.S CONFIRM ON SITE
step ROOF INSULATION MIN. R3.0 ULK
100 INSULATION TO CEILING CAVITY
L
step
O
C
ALL NEW ROOFING STRUCTURE TO ENGINNERS © COPYRIGHT 2020 - M DESIGN
DETAILS THE IDEAS AND CONCEPTS
CONTAINED WITHIN THIS
DOCUMENT AND THE DOCUMENT
WHILST ALL CARE HAS BEEN TAKEN TO ITSELF REMAIN THE INTELLECTUAL
2500
SIZE & REFERENCE DOWNPIPE PROPERTY OF
M DESIGN AND MAY NOT BE COPIED
QUANTITIES, CONTRACTOR TO PROVIDE OR REPRODUCED IN PART OR IN
OWN CALCULATIONS TO ENSURE SIZES WHOLE WITHOUT EXPRESSED
L
L
O
& QUANTITIES ARE CORRECT WRITTEN PERMISSION FROM
O
C
C
MICHAEL BROEREN OF M DESIGN.
600
P
P
D
25.06.20
09.07.20
21.12.20
D
DATE
setback
2000
Northern portion of
LINE OF ROOF OVER
600 7000 253
proposal not approved
FOR BODY CORPORATE APPROVAL
EAST BOUNDARY
DESCRIPTION
ROOF HEIGHTS ADDED
FLOOR PLAN - LEVEL 2
SCREEN ADDITION
1 : 100
3100 1500
REV
OH setback
C
A
B
DP
FOR BODY CORPORATE APPROVAL - NOT FOR CONSTRUCTION
5/18 PEREGIAN ESPLANADE,
ALTERATIONS & ADDITIONS
NORTH BOUNDARY
EXISTING ROOF
DAVID & DJINGSIU CURRIE
2.00°
PEREGIAN BEACH, 4573
EXISTING AWNING
EXISTING ROOF TO BE REMOVED RS
GU
LINE OF WALL BELOW
COLUMNS
BELOW
Project Address:
DPS
2500
2.00°
3100
OH
GU-ex x
EXISTING RS
-e
For:
DP DOWNPIPE TO BE
REMOVED
EXISTING DECK sheet title:
SETBACK
PROPOSED
2000
DP GU DP
FLOOR &
.
ROOF PLANS
APPROVED PLAN EAST BOUNDARY job no:
2017
drawn by:
JM
ROOF PLAN - DEMOLITION Minor Change 51995.1530.05
1 : 100
NOOSA COUNCIL ROOF PLAN - PROPOSED date: 21.12.20
23 December 2020 . 1 : 100 scale (A3): drawing no:
1 : 100 2.1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans (Unit 4) 51995.1530.04.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.