Original source · versioned page text
MCU25 0087 - Reference Document - Coastal Hazard Assessment (As Published)
E
EEZ
WD.602
B R
WD.602
A B C D E F G
D
B
3,000 1,600 3,280 6,150 3,620 8,370
2
'
8
"
E
N
8
9
1
°
0
5
9
8
.
9
'
8
1 1
#LayID #LayID
W
"
'
0
9
'
4
2
.
F F
0
°
3
2
7
POOL POOL
N
1.5m side setback
2,400
2,400
PLANTER
2
'
8
"
E
N
8
9
8
°
5
5
.
8
3
'
7
2m side setback
line of building over line of building over letterbox
N
8
9
8
°
3
5
.
8
7
'
3
2
'
8
"
E
step step step window step step
2 pool fence grated
louvre louvre window louvre louvre
window curtain
grated
pool gate
2
drain sh drain winter sun
6m front setback
balustrade
winter sun
1,600
1,600
FT path
path S join
T flush
3 BED 4 BED 3 3
line of building over
RAMP FFL 1.060 wc FFL 1.060
BAR POOL ROOM TERRACE
(down)
sliding door
C C
ALFRESCO FAMILY
line of building over
sliding door
FFL 25.420 FFL 25.420
vehicular gate
DRIVEWAY
grated drain
C FFL 26.270 FFL 26.270
SHARED FT FT C
3,040
3,040
c.s.
c.s.
WD.603 flush flush WD.603
FT TF
ENS DS
join b. join b. table
robe robe
E
E
E
pool gate join join
door door
E
E
tennis
2m rear setback
"
"
"
"
"
'
'
'
'
'
7
7
7
curtain
4 4
flush flush
0
0
0
5
1
3
5
5 4 3 2 1
5
5
5
LINK
'
'
balustrade
5
6
6
3
4
'
'
'
BBQ
.
.
.
.
.
0
0
1
1
1
c.s.
9
9
9
6
9
flush TF FT
FFL 26.270
°
°
join TF R:170
°
°
°
4
3
3
3
4
0
0
LINEN G:250
0
0
0
SUN
flush flush flush window
1.5m rear setback
SUN c.s.
S
S
c.s.
N
N
N
flush balustrade door
join TV LANDING join gate
2,960
2,960
sh join join drop curtain
c.s. FFL 26.270
surf gear
FOYER zone
wet suits
TF
LDY MUD
W
flush
FFL 1.060 c.s.
door
FT
"
OFFICE/ PDR FFL 25.420 RM
'
6
flush FT join
3
5
seat
BEDROOM ENS. b.
BED 2 TURF
window
b.
line of building over
'
5
5 5
wc FT wm dr. FT
.
sliding door
2
art
6
FFL 26.270 FFL 25.420 FFL 25.420
°
7
join join
SEATING
b
8
flush FT
c.s. C
1
TF
lift door
join
A entry door A
S
curtain
seat
WD.601 LIFT wc
WD.601
window
4 3 2 1
3,040
3,040
flush
robe STAIR R:170
G:251 FT
sh ARRIVAL
gate
3 2 1
flush bath FFL 24.570 FFL 23.890
2 robe join R:170
SAUNA FFL 26.270
door
2m side setback
1 PV
4 3 2 1 G:250
PV
to be selected join
ENTRY 3 2 1 R:170
S
9
0
8
°
3
.
0
7
'
5
0
'
"
W
5 4 3 2 1
ice bath FT
1.5m side setback sliding doors ENTRY
6 6
gate FFL 25.930 G:250
FFL 25.420
FT
OUTDOOR
S
9
0
8
°
5
.
0
3
'
9
0
'
"
W
R:170
POOL SURFCRAFT STORE
gate
2 1 FT
AC 5 4 3 2 1 G:250 SHOWER
gate
gate
sh
EQUIP AC AC
UNITS w.line
PV
BRE
EZE
N
9
1
0
1
°
0
0
.
0
'
0
0
'
"
W
9,000 COMPLIANT BUILT TO BOUNDARY WALL
3,000 1,600 3,280 6,150 3,620 8,370
WD.602
summer sun
summer sun A B C D E F G
D
path
path
DA1 Development Approval application
issue issue / amendment
27.06.25 LF JH ML EN
issue date drawn by
client
Christian Seymour
project
Seymour The Esplanade
location
17 The Esplanade Sunshine Beach
WINTER
SUN PATH EXT. FINISHES LEGEND BLK masonry blockwork. FT1 floor tile (no refers to type). MR1 metal roof - (no refers to type). SP structural post, refer engineer. MAIN LEVEL PLAN
Sett am
) AS aluminium screen. C carpet fire fireplace NGL natural ground line. SF structural footing, ref. eng. Aboda Lee Foster • director
Design p - 0424 620 247
Scott Falconer • director
p - 0431 267 157
in g5 in g (7 Group e - [email protected] e - [email protected]
pm Ris
AL aluminium louvres, refer sched. CS concrete slab. flue flue kit PF compliant pool fencing TIM timber cladding. the aboda design group trust
ABN 56 266 884 746
Level 2, 1794 David Low Way Coolum Beach,
Q. 4573. PO box 2449 Noosa Heads Q 4567
MER
N
t/a aboda design group • BSA License -15058097 • www.aboda.com.au
SUM PATH ASD aluminium sliding door. DP down pipe. GS garage slab. PW parapet wall. TD timber deck.
SUN • This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Ris
pm in
in g 5.3
0 g (6
.30
am
AFD aluminium framed door. DS driveway slab. HWS hot water service. PS patio slab. TF timber floor. Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
Sett )
AFW aluminium framed window. FCA fibre cement awning. HR handrail. PV photovoltaic cells. TFD timber framed door scale Scale as noted @ A3 issue
drawing no.
MAIN LEVEL PLAN sun control battens, refer detail. fibre cement ext. cladding. LPG gas bottle. rain water tank. vergola.
WD.202
BA FC LPG RWT VER
SCALE 1:100 @ A3
BAL1 balustrade-(no refers to type). FG fascia gutter. NGL NRG board SBJ silicone butt jointed glass. DA1
Document Set ID: 24631530
Version: 1, Version Date: 24/03/2026
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewSearchable page text hides email addresses. Original files are unchanged and may show email addresses.