PROPOSED 3000L ATTENUATION TANK.
PROPOSED 450X450 FIELD INLET PIT.
UDNERGROUND GAS BOTTLE CONNECTION TO ROOF DRAINAGE AND STORMWATER NEW TIMBER PALING FENCE
REFER CIVIL.
OUTLET TO HYRDAULIC ENGINEERS SPECIFICATION.
PROVIDE 1.5M WIDE CONRETE
FOOTPATH FOR LENGTH OF A B C D E F G
STREET FRONTAGE. REFER
NSC STD DWG RS-065. 6,310 2,200 2,610 3,110 7,140 3,950
A 40.000 B E
FNC 501 501 401
178°00'20"
NEW FENCE
NEW CONNECTION TO
G.07
EXISTING SEWER SERVICE
W.33
GARDEN
1
1,870 750
D.01 EG
W.06 2
W.08
W.35
W.28 W.24
FNC
W.27 W.26 W.25
3
ROBE
AD.09
PLANTING
AD.10 W.07
1,440
D.02
Residence One
ROBE
LETTERBOX
RS1 VP
D.08
D.06
W.29
D.12 ROBE ROBE
AWN POOL 4
RS1
ROBE
PROPOSED RESIDENTIAL VP AD.08
W.12 POOL BY OTHERS
D.04
W.23
1,355 1,260 1,730
DRIVEWAY CROSSOVER D.07
ROBE
D.03
IN ACCORDANCE WITH D.14 S
88°00'20"
D.15
402
14.200
IPWEA RS-049 & 050 D.16
D.09
5
AD.07
W.11
D.13 D.17
D.05
D.11
W.30
FNC
AWNING
6
UNDERG
W.31
W.01 DP
1,450
AD.01
W.32
N D.10
"
ROUND
260°00'10
20.360
401 EG
PW
10
12
13
14
15
16
17
11
1
2
3
4
5
6
7
8
9
10
12
13
14
15
16
17
11
1,545
1
2
3
4
5
6
7
8
9
1,730 1,260 1,450
SEWER
AD.02
D.30
W.13
C EG C
502 W.02
W.14 DP 502
7
AWNING
W.15
D.31
D.25
AD.06
W.10
PROVIDE NEW KERB ADAPTOR D.36
D.29
OUTLET AS PER NSC STD DWG
D.33 D.37 POOL BY OTHERS
8
D.35
RS-081, CONNECT STORMWATER
ROBE
D.22
AND MAKE GOOD
W.22
PLANTING
LETTERBOX
VP
ROBE
D.27 D.34
D.21
RS1 AWN W.09
AD.05
POOL
W.16
ROBE ROBE 9
D.28
D.26
D.32
VP
1,440
ROBE
D RS1 D
502
Residence Two 502
D.23
AD.04
ROBE
AD.03 W.04
10
W.18 W.19 W.20
750 1,870
W.17 W.21
81°24'20"
GARDEN
W.36
6.000
W.03
EG
W.05 11
D.24 EG EG
W.34
12
G.06
NEW FENCE
358°00'20"
A B W
42.145
501 501 402
FNC
NEW CONNECTION TO
EXISTING WATER SUPPLY
H I J K L M N
PROPOSED 3000L ATTENUATION TANK.
PROPOSED 450X450 FIELD INLET PIT. CONNECTION TO ROOF DRAINAGE AND
UDNERGROUND GAS BOTTLE NEW TIMBER PALING FENCE
REFER CIVIL. STORMWATER OUTLET TO HYRDAULIC
ENGINEERS SPECIFICATION.
GENERAL NOTES
SITE ADDRESS 3 Delorme St Noosa Heads Q 4567
LOT RP160425
LOCAL AUTHORITY Noosa Council
SITE AREA 832.37m2
B L A C K Project: Drawing Title: Project No. Checked By Drawing No.
Rev Date Description Use figured dimensions in
Contact information:
preference to scale. All dimensions
B 16/02/2023 FOR PRICING to be varified and checked on site.
These designs, drawings,
25 / 91 Poinciana Ave. Tewantin QLD 4565
Architect Registration # 5386 QLD
New Duplex, 3 Delorme Street PROPOSED SITE PLAN 202242 PT WD104
For: Capital Prudential
W O O D
specifications and the copyright
thereof are the property of Ph: 07 53 01 9677
Blackwood and must not be used,
[email protected] 3 Delorme St Noosa Heads Q 4567 Scale Date Project Stage Revision
retained or copied without the
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 1:200 @ A3 17/02/2023 FOR PRICING B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.