Appendix A - Architectural Plans

of 10

Page text shows just the words. Original shows the document exactly as it was published.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
 DP       DOWNPIPE ZINCALUME
 EG       EDGE GUTTER TO MATCH ROOF
                                                                                               4080         6000                                     5420

                                                                                                                   15500


                                                                                                                                    21180




                                                                                                                                                                                                  STORMWATER
                                                                                                                                                                                                  TO EXISTING
                                                                                                                                                                                                  LAWFUL POINT
                                                                                                                                                                                                  OF DISCHARGE




                                                                                          DP




                                                                                    455
 NOTES:
                                                                                                                                                                     EG
 All work to conform with Part MP 4.2 of the Queensland                                        5°
 Development Code (QDC) (Water Saving Targets).                                                                                                      5°

 Roof stormwater is to discharge to local government                                                  15°                  15°
 requirements and approval. Downpipes not connected
                                                                                          EG
 to rainwater tank/s to discharge to interallotment
                                                                            11120




 drainage system/ to nominated discharge points via
 bubbler system/ to discharge to street channel system.

 Based on assumed 5 minute rainfall intensity - 248mm/h
 20 years recurrence interval.                                                                                                                                       DP
                                                                                          DP

 Gutters & downpipes shall be in accordance with                                                                                                                          EG
 AS/NZS3500.5 domestic & Part 3.5.2, Vol 2 of the NCC.                                                                                                                               DP


 All downpipes to be 90mm/100mm U-PVC.
 All gutters to be 150 Quad Gutters (8600mm² Cross section area).
 Falls to be in accordance with clause 3.5.2.4, Vol 2 of the NCC.




                                                                                                                                                                               15°
                                                                     3090




                                                                                                                                               15°
 •    Effective roof catchment area 183.0m²
 •    Number of downpipes 4
 •    Roof catchment per downpipe 45.75m²
 •    Downpipes must not serve more than 12m of gutter length for each
      downpipe
 •    Total rainfall intensity 183m² X 248mm/45.75= 992L/min
 •    Stormwater pipes - 100 dia. Laid at 1 in 100 minimum grade.

 Downpipes are to be located where they will not
 create a hazard to building users nor impede window
 & door openings and the like. They are to be installed
 as close as practicable to the supporting structure
 while maintaining termite inspection clearances of
 25mm. Downpipes are to be protected from potential
 mechanical damage, be installed no less than 100mm
 from electrical cables & gas pipes & no less than 50mm
 from other services (AS3500.3.2 S4.11)
 Downpipes are to service 12m maximum
 gutter length & be within 1.2m from each
 valley unless overflow is provided for
 (NCC Vol2 P3.5.2.5)



                                                                                                                                                                   CD4a
                           new build                                                                               REV           DESCRIPTION                DATE
                                                                                                                                                                   ROOF MAIN         JOB:         21.34
WALK STUDIO                For:   ROBIN YATES                                                                                                                                        DATE:        01.06.22
                                                                                                                                                                                     DRAWN:       J.Walker
walkstudio.com.au
0409.921.601
                           SMOKE HOUSE
QBCC #15018637             16 Reserve St Pomona                                                                                                                    3.1
                                                                                                                                                                                     SCALE(A3):   1 : 100
Log in to download the original file

Appendix A - Architectural Plans.pdf · 2.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.