8m Max Build Height
From NGL Colorbond trimdek roof sheeting
fixed to manufacturers specification
for required wind category. (2° pitch).
450mm deep Heka hood to Colorbond slotted gutter, fascia
manufacturers specifications. to match roofing. Fix to manufacturers
specification.
Aluminum framed windows
Living/ Kitchen Joinery
to manufacturers specification.
Pitching Height
2440
2400
Joinery
2100
Scyon Axon 133 (Or similar)
cladding to manufacturers detail. Privacy screen
Privacy screen Privacy screen
Ceiling Height
2400
Joinery
2100
Tiered retaining walls
to engineers detail.
500
Approx. Proposed Ground Line. Aluminum framed sliding doors
Approx. Existing Ground Line. to manufacturers specification.
450mm deep Heka hood to
WEST ELEVATION manufacturers specifications.
Scale : 1 : 100
Select 50 x 50 P.C. Aluminium batten screen Colorbond trimdek roof sheeting
@ 100 crs to manufacturers detail. 8m Max Build Height fixed to manufacturers specification
From NGL for required wind category. (2° pitch).
SHS post to engineers detail.
Aluminum framed windows
Parapet flashing to builders detail. to manufacturers specification.
Colorbond slotted gutter, fascia
Framed extrusion to engineers detail to match roofing. Fix to manufacturers
with EPS rendered and painted over. specification.
Living/ Kitchen Joinery
Pitching Height
2440
2400
Scyon Axon 133 (Or similar)
Joinery
2100
cladding to manufacturers detail.
2000
1000h solid balustrade
Fill
Ceiling Height
Built up blockwork retaining
2400
2725
Joinery
2100
500
wall to engineers detail.
1761
1000
Tiered retaining to
Select feature timber cladding to engineers detail.
manufacturers specifications.
Approx. Proposed Ground Line.
NORTH ELEVATION Approx. Existing Ground Line.
Scale : 1 : 100
Revision Schedule Client Name: RLH Homes
Sheet Number: U06 Project Number:21-038
Revision Number Revision Description Revision Date Issued by Project Address: 4 Ventura Street, Sunrise Beach
Climate Zone: 2
Wind Category: To engineers spec.
Elevations
Email: [email protected]
Website: www.iconbuildingdesign.com.au Project Issue Date: 11/01/2024 Project Status: PCD 19 Scale: 1 : 100
Phone:Set
0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: Aaron Waters QBCC LIC# 126221
Document ID: 23959990
Version: 1, Version
C COPYRIGHT Date:and23/07/2025
The Drawing the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.