Council archive · source document
Approved Plans - MCU25/0021
Plans and drawings: the text below has words only, no drawings.
Very large file (14.4 MB): may take a few minutes to open.
Original PDF page 4, section 1. The text section number identifies this passage in the reader.
summer sun
A B C D B E winter sun
F G
path
WD.602
path
WALL LEGEND
2,810 2,690 3,690 6,010 5,300 2,500 RC masonry blockwork
1 35.210 1 RC pool shell/off form concrete
N 19° 1' 15" E POOL
90MM ext. timber frame
PLANT
LAWN TERRACE BELOW TERRACE BELOW
2,510
2,510
AC BELOW 70MM int. timber frame
BELOW
building below 2m SIDE SETBACK PLANT Indicates extent of
36.00 chs shs structural posts - refer
35.
34.00
BELOW
N 70° 59' 56" W
23.210
engineer.
00
2.5m SIDE SETBACK
2 2 GENERAL LEGEND
N 70° 59' 56" W
23.210
6m REAR SETBACK
fixed fixed fixed fixed
join join fireplace
D04 denotes door number
louvres
join
tv
b wc
PANTRY KITCHEN TF W04
c.s.
denotes window number
ENS
3,490
3,490
join TF FFL 43.000 RL 17.200 denotes finished floor level
chair b FFL 43.000 table
6m FRONT SETBACK
10m FRONT SETBACK
c.s.
UNROOFED + RL 17.700 denotes spot level
FT WIR fr.
FFL 43.000
join
LIVING TERRACE 50 step denotes change in level
sliding door
island bench
casements
FFL 43.000 FFL 43.000
DRIVEWAY
TF join
PDR denotes floor waste
3 3
chair fw
b wc TF FT
BELOW sh
FT denotes hard wired smoke
alarm to ABCB HP Part 9.5
8,900 O.M.P. POOL hwsa min 300mm from wall
8m REAR SETBACK
N 71° 0' 0" W
S 71° 0' 0" E
door
5° denotes direction of roof fall
BELOW
15.094
15.091
UNROOFED
2,890
2,890
N 71° 0' 21" W
11.589
lift door
N 71° 0' 22" W
11.077
N 71° 0' 35" W
11.094
N 71° 0' 22" W
11.087
MR denotes roof material
louvres
TERRACE DINING
balustrade
FT FFL 43.000 TF
FLOOR FINISH LEGEND
sliding door
table
FFL 43.000 casements
LIFT
4 4 FT1 FT2
balustrade
MASTER R:170
G:250
Indicates extent of TILE
ALFRESCO
1,720
1,720
BED fixed window 1 balustrade
casements
balustrade
STAIR
FFL 43.000 2 FFL 43.000 C Indicates extent of CARPET
LAWN PLANTER
3
VOID FT
5 5
TF art 4
5
BELOW BELOW VOID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 TF TD Indicates extent of TIMBER.
A STAIR
louvre
1,680
1,680
FSC
R:180
WD.601 G:250 GARAGE D'WAY
35.
3 4 .0
00
Indicates extent CONCRETE
3 3 .0
GS DR
00
35.
6 6
fixed sliding door
0
0
PC HC
STAIR N 71° 0' 15" W
23.209
2.5m SIDE SETBACK FSC
POLISHED HONED
BELOW N 71° 0' 34" W
23.209
2m SIDE SETBACK
FINISH CODE LEGEND
2,610
2,610
PLANTING
BELOW PLANTING denotes additional 'extent' information
BELOW (xxxxxxxx)
denotes finish, refer 1000
7 7
XX
series drawings for schedule
35.210
2,810 2,690 3,690 S 19° 1' 0"6,010 5,300 2,500
W BR JXX
denotes item and number.
EEZ refer to Joiner for details
E
A B C D summer sun E F G winter sun
SU
path path
BREEZE
B
N
DA3 Development Application
WD.602 issue issue / amendment
07.04.25 LF JH EN
issue date drawn by
client
Kerry Bone
project
Bone Park Cr
location
5 Park Crescent Sunshine beach
EXT. FINISHES LEGEND BLK masonry blockwork. FT1 floor tile (no refers to type). MR1 metal roof - (no refers to type). SP structural post, refer engineer. UPPER LEVEL PLAN
SU N P
SU
Setting 5 pm
MM AT
Se Aboda Lee Foster • director Scott Falconer • director
aluminium screen. structural footing, ref. eng.
ER H
tt ing AS C carpet fire fireplace NGL natural ground line. SF Design p - 0424 620 247 p - 0431 267 157
NOOSA COUNCIL 5 .3 Group e - [email protected]
SUN
WIN ATH
e - [email protected]
0p
m the aboda design group trust Level 2, 1794 David Low Way Coolum Beach,
aluminium louvres, refer sched. concrete slab. flue kit compliant pool fencing timber cladding.
TER
AL CS flue PF TIM
P
ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
APPROVED PLAN t/a aboda design group • BSA License -15058097 • www.aboda.com.au
N
MCU25/0021 16 MAY 2025 ASD aluminium sliding door. DP down pipe. GS garage slab. PW parapet wall. TD timber deck. • This drawing is to be read in conjunction with engineers drawings & reports • Construction
Ris to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
in g( Copyright for design & drawings remain the property of the authors • Verify all dimensions on
7a AFD aluminium framed door. DS driveway slab. HWS hot water service. PS patio slab. TF timber floor.
Rising (6.3
m) site prior to commencement of any works • These drawings are not to be used for scaling.
AFW aluminium framed window. FCA fibre cement awning. HR handrail. PV photovoltaic cells. TFD timber framed door scale Scale as noted @ A3 issue
0 am)
UPPER LEVEL PLAN
drawing no.
DA3
WD.203
BA sun control battens, refer detail. FC fibre cement ext. cladding. LPG LPG gas bottle. RWT rain water tank. VER vergola.
SCALE 1:100 @ A3 BAL1 balustrade-(no refers to type). FG fascia gutter. NGL NRG board SBJ silicone butt jointed glass.
Document Set ID: 23681088
Version: 1, Version Date: 09/04/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU25/0021Related documentApplication case desk ↗
About this file
- File size
- 14.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.