Council archive · source document
Revised Proposal Plans (rec 29.6.26) · MCU26/0010
Plans and drawings: the text below has words only, no drawings.
Original PDF page 7, section 1. The text section number identifies this passage in the reader.
r 44.9
4
1 3
2
A5
A4
A3
A2
A1
WALL HEIGHT FROM NGL
DOES NOT EXCEED 2m
WALL HEIGHT FROM NGL
DOES NOT EXCEED 2m
POOL SERVICES
2000h CONC. BLACK WALL
OUTDOOR KITCHEN
HATCH DENOTES WALL AREA ABOVE 2m
NOTE MAX HEIGHT IS 2.5m
E RED
COV
GARDEN 68
4,5
A LL
LACK W
NC. B
h CO
800
2000
GATE
2,000
PDR
MB
JOINERY
OUTDOOR LOUNGE/DINING
9
6.28 x 11.30
2700 CH
8
7
10 SPA POOL
2.06 x 2.31 7.50 x 3.91
GUEST BED
11
6
BATH 1 3.01 x 3.01
12
5
2700 CH
13
B4 4 B4
14
3
MPR
15
2
3.84 x 3.54
16
1
UP
DN 17
2700 CH
GATE VOID
GATE
B3
STEPS PORCH ENTRY B3
3.30 x 1.71 5.09 x 1.71
2700 CH
JOINERY
JOINERY
WALK WAY ABOVE
B2 B2
B5 B5
CONCEALED
FLL. 35.77
DOOR
4,540
2700 CH
FORMAL DINING
1,200
6.01 x 4.75
2700 CH LOUNGE
6.00 x 4.90
E
OFFIC
6.85
2700 CH
6m SET BAC
2.00 x CASUAL DINING
1,300
MEDIA 3.54 x 3.15 KITCHEN
B1 B1
3.95 x 4.63 5.23 x 4.76
FIREPLACE
2700 CH
K LINE
FR IND.CT OV
BUILT IN SEAT JOINERY PLINTH
1,600
FUTURE
LIFT SEAT
4,67
LDRY PDR 5
B WIP 2700 CH
2700 CH
B
5.46 x 1.12 4.19 x 1.26
LOUVRES
JOINERY
DN
2,600
DN
2,000
1,508
1. BASEMENT: 235.8
2. GROUND LIVING: 283.3
3. FIRST FLOOR LIVING: 256.9
4. GROUND FLOOR ALFRESCO: 71.3
A5
A4
A3
A2
A1
A
5. GROUND FLOOR PORCH: 4.7
6. FIRST FLOOR FRONT BALCONY: 24.5
7. FIRST FLOOR REAR BALCONY: 17.0
8. ROOF TOP TERRACE: 39.2
932.7 m²
0 1m 5m
Suite 7 / 10 Grebe St, Peregian Beach [email protected] www.suncoastbuildingdesign.com.au mob: 0401565629 mob: 0491289102 Revision Proposed Residence Address Client Avalon Homes Scale 1:150, 1:1
QBCC No: 1257143 (low rise)
Rev A - Amend Front roof pitch to 5 degrees Rev F - DA Plans - 20.08.25
Rev B - DA Issue Rev G - DA Plans - 09.10.25
#Project Description
This plan shall remain the sole property of Suncoast Building Design and must not be given, lent, hired out or otherwise disposed of or copied without the
Drawn MM/SB Page No. 7
Rev C - Major revisions per client meeting Rev H - RFI - 29.10.25
written permission of Suncoast Building Design.
Rev D - Garage reduced Rev I - RFI - 13.02.26
Note: all dimensions/engineer details and relevant information to be checked and confirmed by builder /client. Suncoast Building Design does not take
any responsibility after drawings have been checked and confirmed by builder/client or construction has commenced. Rev E - Updates as requested by client - 14.08.25 Rev J - RFI - 22.05.26 Job No. 20.148 Date 22.05.26 Stage DA Plans Drawing GROUND FLOOR PLAN
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Proposal Plans (rec 29.6.26).pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.