Skip to the record
The definitive source for everything Noosa Council.

Council archive · source document

Development Application Part 2 - Environmental & Stormwater Management Plans · OPW11/0335

of 275

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Very large file (49.6 MB): may take a few minutes to open.

Log in to see the plans as drawn
     Sunshine Coast
                                                                                                                                            HOW TO READ (Version 2.0)

                                                                                   AS-CONSTRUCTED STORMWATER PLANS

THIS HANDOUT IS DESIGNED TO ACT AS A SIMPLE GUIDE TO                                                Stormwater Pit                                                                                                                  Stormwater Structure
READING AND UNDERSTANDING THE INFORMATION LISTED
                                                                                                                                                            P 24626
ON A STORMWATER INFRASTRUCTURE PLAN AND DATA
TABLE.                                                                                              Stormwater Pipe
While care has been taken in preparation of both this handout and the plan you
received, Sunshine Coast Regional Council accepts no responsibility for the
accuracy of any information. The applicant should rely on both checking of                                                                                                                                                                    - PT18071
                                                                                                                                                                                                                                              f24G23
formulas and workings out of information as well as field investigation in order                    Asset ID                                                                         ^yu one.s 'a
to validate the information shown on the plan.


                                                                                                    Road Name                                                                                                                             PT24624
                                                                                                                                                        0
                                                                                                                                                                                                 ,1E9_171065
As Constructed Plan Details                                                                        Lot and Plan Number                                                                                                       PT24
                                                                                                                                                       a.
Plan Title
        Stormwater Pits
                Asset ID                                   Pit Number                                  Level                            Dimensions                      Inlet Type                        Stormwater Quality
                                                                                                                                                                                                          Improvement Device                        Overland Flow
                PT1 8071                                         8/K                                    3.01                        Humeceptor STC3                         SQID
                PT24623                                          7/K                                      3                               800X600                          ME (L)
                                                                                                                                                                                                                                            Contact:
                PT24624                                          2N                                       3                               800X600                          ME (C)
                                                                                                                                                                                                                                            CUSTOMER SERVICE on
                PT24625                                          1N                                     3.57                              900X600                FI - Type 2 900X600                                                        (07) 5475 8501
                                                                                                                                                                                                                                            www.sunshinecoast.qld.gov.au
                PT24626                                          2/K                                    3.44                              900X600                          ME (C)
        Stormwater Pipes
                                                        Upstream Invert                                                                                                                                                 Stormwater Quality Improvement Device (SQID)
                Asset ID                                     Level                      Downstream Invert Level                            Material                      Pipe Size
                                                                                                                                                                                                                        Where a SQID device is present, an orange dot will
                PS26025                                         0.231                                 -0.017                                 RCP                           10500                                        appear on the ascon plan. The inlet type field in the
                                                                                                                                                                                                                        data table will indicate that a particular pit is a SAID.
                PS26026                                        -0.017                                  -0.03                                 RCP                           10500                                        The dimension field in the data table will indicate the
                PS26027                                        -0.055                                 -0.076                                 RCP                           10500                                        type of SAID that has been installed.

                PS26028                                         1.988                                  1.748                                 RCP                            3000
                PS26029                                         1.567                                  1.432                                 RCP                            3000
                PS26085                                          0.12                                     0                                 RCBC                        2700X2100
                                                                               This plan was prepared for purpose for indicating the position                 NOTE                                                      IMPORTANT
                                                                               of Stormwater infrastructure only and should not be used for any               While a majority of the plans are printed out in metric
  HOW DO I DETERMINE THE DISTANCE FROM THE BOUNDARY                                                                                                                                                                     As Constructed Plans are to be read in conjunction
                                                                               other purpose. The stormwater information shown on the plan has                units and to a scale, the customer should be aware
  TO THE STORMWATER INFRASTRUCTURE?                                            been derived from either field survey or historical detail plans thus                                                                    with the data table at all times. The Asset ID
                                                                                                                                                              that occasionally a plan maybe printed from an old
                                                                               the accuracy can not be relied upon. In particular no reliance should          Imperial plan and measurements are in decimal feet. It    corresponds found on the plan (page 1) corresponds to
  To define an accurate location of infrastructure the following               be placed on the information on this plan for any financial dealings                                                                     the data listed in the Data Table eg. PT24623 relates
  should be observed. This plan does not guarantee the location of                                                                                            would then be up to the customer to convert the plan
                                                                               involving the land.                                                            from imperial units to metric.                            to Stormwater Pits.
  boundary pegs or fences. The owner must have an identif ication
                                                                               This note is an integral part of this plan.
  survey and detail survey performed by a licensed surveyor to
  accurately determine the distance from the boundary to the
  infrastructure. The detail survey is used to locate the improvements
  on, above or under the land (i.e. Stormwater Pipe). This information
  has to be related to the property boundaries of the parcel of land
  therefore an identification survey is required, which identifies where
  the title boundaries are. An identification survey will result in new
  pegs or other markers being placed and measurements taken to the
  unorovements                                                              T 1AIS'As Con Development\PDF Export\System Files\HOW TO READ Stormwater Version 2 doe            Updated on 29 July 2008

Used in these records

About this file

File size
49.6 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application Part 2 - Environmental & Stormwater Management Plans.pdf · 49.6 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.