Proposal Plans
Plans and drawings: the text below has words only, no drawings.
Very large file (15.0 MB): may take a few minutes to open.
Original PDF page 6, section 4. The text section number identifies this passage in the reader.
RAISED
POOL a te PLANTER
ol g
FFL 23.340 NEW mosaic po
tiling to pool
6 step <1.0m
5 BLK
EXT. FINISHES LEGEND
POOL
AFD aluminium framed door. HH 'Heka' hood, ref sched.
AFW aluminium framed window. join joinery item, by joiner
4 FT
WT
AL aluminium louvres, refer sched. MR1 metal roof - (no refers to type). NEW mosaic FFL 23.340 3
AS aluminium screen. PB plasterboard lining, ref. sched. tiling to pool 2
GRAVEL DA
issue
For Development Approval
issue / amendment
ASD aluminium sliding door. PF compliant pool fencing
1 PATH 17.09.25 SF EN
BAL balustrade PW parapet wall. NEW POOL R:180
issue date
client
Jenny and Nigel Starr
drawn by
masonry blockwork. polymer render
DECK
BLK REN
project
C carpet SBJ silicone butt jointed glass. 2505 Star Tropicana Rise
location
conc reinf. concrete wall/pool shell SP structural post, refer engineer.
FFL 23.340 20 Tropicana Rise, Castaways Beach
CS concrete slab. STR1 stair (no. refers type) WT MAIN LEVEL PLAN
FCA fibre cement awning. TIM timber cladding, ref. schedule
RL 23.340 FT
timber
Aboda Lee Foster • director Scott Falconer • director
Design p - 0424 620 247 p - 0431 267 157
FC fibre cement cladding TD timber deck. Group e - [email protected]
the aboda design group trust
e - [email protected]
Level 2, 1794 David Low Way Coolum Beach,
ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
FG fascia gutter. TF timber floor. t/a aboda design group • BSA License -15058097 • www.aboda.com.au
VIE
EXISTING
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
FT1 floor tile - (no refers to type). TS timber screen, ref. detail to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
BAL
WI
fire fireplace VER vergola.
MAIN LEVEL PLAN ALFRESCO scale Scale as noted @ A2
A3 issue
DA
flue flue kit VJ1 vertical joint lining, ref sched. drawing no.
NG
WD.202
(no. ref. type).
SCALE 1:50 @ A2
'Heka' hood, ref sched.
FFL 22.090 RAISED
HH
Y
CO
PLANTER
G
L ON