Council archive · source document
Operational Works Application OPW18/0016
••
HEIGHT ABOVE INVERT ro ~ ~
0 u "',
0
C
Of CHANNEL (mm) ~ ~ N
N N
0
D
Control joint DISTANCEfROM INVERT 0 "! 0
.-;
~
.-; -?
Of CHANNEL (m) ci
• 1500 1500
Kerb invert
e-I Gorage/
"-
Slope moy vary
Carport slob
note 12
Rood surface \ "D£~
'-'
1500
Transition
'0
\ in €I
Reinforced Sl72 fabric min
::. "n B 1 In 0 1500
Roll under Gorage/
Sand blinding loyer 50 max Carport slab
Galvanised/stoinless Sow cot 011ke<b, to ~ Cont.o' ;0'"t7
steel dowels 400 tong allow cleon removal 01 (If required)
R16 0 450 centres bock 01 kerb and
channel
BREAKOllT lYPE 1YPICAL PROFILE DRIVEWAY ACCESS
SECTION A SECTION B
Refer drowing ReIer drawing
RS-049 RS-Q49
AU appropriate permits must be obtoined from relevant council, specifying crossing type, 13. Path zone width may vary to match existing concrete pathways and verge profiles.
construction materials, location, levels, surface finishes and dimensions, prior to any excovotion. Path eorthworks adjoining concrete must be well compacted.
2. A1ternotive moteriols for construction, other thon reinforced concrete, refer 10 relevant council 14. Earthworks cui and filt balters lrom edge of driveway or path to natural surfoce to be
for opproval. maximum grade at 1 in 10 and fully turfed prior to council inspection.
J. Crossing 10 be constructed squore to the street alignment, wholly contoined within the site 15. Existing path to be longitudinally lronsitioned to new drivewoy at 0 maximum grade ;If 1 in 10.
frontage from invert of chonnel to property boundary. 16. Plain concrete surfoces to be heo'lY broom finished.
4. One access to be constructed per allolment unless alherwise approved by relevonl Council. 17. Decorotive surfoces are subject \0 relevant council approval, where apprO'ied, to have a 5mm
5. To reduce impact on available street parking, cansideration is to be given to visitors and max depth variation in the finished surface profile. All finished surfaces of driveways are to
neighbouring property's parking needs when selecting a crossing location. comply with the requirements of AS/NZS 3661.1 slip resistance of pedestrian surfaces.
6. Crossing to be located c1eor of existing gully pits. where this cannot be achieved, the gully pil Exposed aggregate finish subject to relevant council approvol due to environmental reasons.
and pipework may be relocaled at the property owner's expense, subject to approval of the 18. Expansion joints to be 10mm thick full depth closed cell cross linked polyethylene foom (55
relevant council. 150 kg/m), or 8.5mm thick bitumen impregnated compressed granulated corkboard, i"lsloUation
7. Crossing to be located clear of all service authority's fittings, manholes and pits. Subject to to monufocturers' instructions. Seol surfoce of joint with" a suitable polyurethane sea'onl.
relevant Council approval. where this cannat be achieved, existing service pits are to be 19. Concrete surface tolerance to be, ~Cover .3 metre sections.
contained wilhin the area of new driveway, pit surface to match opproved driveway finished 20. Concrete to be minimum grade N32 in accordance with AS 1379 cnd AS 3600.
levels. 21. Concrete construction to comply with the requirements 01 AS 3600, concrete code.
B. Kerb adaptors ond associated roafwater droinage 10 be located clear 01 vehicular crossings. 22. Reinforcement fabric 10 AS 1304, 50 top and edge cover, lop fabric 250.
9. Council will not relocate traffic islands or provide breaks in Iraffic islands to allow driveway 23. Control joints arc to be sealed with 0 low modulus seU priming sealant to the manufacturers
access. specificotion. refer RS-065.
10. for waler sensitive urban design verges, the vehicular crossing is subject to relevont council 24. formwork and reinforcement sholl be in ploce and inspected and approved by the relevant
design ond approval. council prior to placement of concrete.
11. "Driveways must achieve a high point of 250mm above invert 01 kerb to ensure stormwoter is 25. Maintenonce of the crossings are the responsibility of the property owner.
contoined within the rood reserve as per requirement 01 O.U.D.M. (Queensland Urban Drainage 26. Drawing 10 be read in conjunction with RS-049.
monuol). This constraint may be varied upon the approvol of the relevant Council. 27. Cross fall of e~istin9 pavement adjacent to the driveway 10 be checked. If cross loll exceeds
12. Under special circumstances Council may approve a rising grade of 1:6 max or folting grade 3%. relevant Council will decide if driveway needs to be re-designed to ensure satisfactory
of 1:20 min longitudinal grades olong property boundary must allow for free drainage and clearonce for vehicles.
pedestrian safety. 28. All dimensions Ofe in mitlimetres unless shown otherwise.
lne1lll dro"ings hove bHn de-nlape1:l in consultalion bel,,"" tile parlicipalinQ Couotils.
BEfORE: USE, tne user sholl confirm lllat the dro"inQ no, been odopted by the appropriate Cwncll.
n
~
INST1TlITE OF PUBUC WORKS ENGINEERING AUSTRAlASIA
STANDARD DRAWINGS
DRIVEWAYS
RESIDENTIAL DRIVEWAYS
PlAN 2 OF 2
RS-050
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Operational Works Application OPW18/0016Related documentApplication case desk ↗
About this file
- File size
- 9.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.