RFI - Effluent disposal report

of 8

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

 iDesign
    wastewater                      solutions
                                                                                       Sunshine Coast Office
                                                                                       PO Box 6218
                                                                                       Mooloolah Valley Q4553

                                                                                       P. 0407 887 321
    Biowater Designs Pty Ltd QBCC Lic 1049265                                          E. [email protected]




                                              NEW DWELLING
                                                  &
                                           SHED WITH AMENITIES


                                       SITE & SOIL EVALUATION

                                                  Lot 3 SP 266744

                                                   Area: 2.244ha

                                       Address: 5 Figbird Ct, Lake McDonald

                                             Date: 26th September 2019

                                            Reference No: Figbird/5/2019



INDEX:

1.0 Introduction:
2.0 Site Description:          p2
3.0 Soil Investigation:
3.3 Soil Classification
4.0 Recommendations:           p3
5.0 Design Calculation                               IMPORTANT DIRECTION
5.1 LAA Design:           p4                         Do not install from this design until it is
                                                     Stamped and Approved by the Local Authority.
                          p5                         Council may make changes to this design as part             reuse
6.0 Site Plan
                                                     of the approval process. Only install from Stamped
Contour Plan              p6                         Approved Plans and refer to the Approval Permit for         recycle

Site Classification       p7                         possible changes.
                                                                                                                 retrieve
Articulation Joints Illustration      p8
                                                                              C Copyright Lance Picton 2019 design & content. 1/8
Log in to download the original file

RFI - Effluent disposal report.pdf · 1.1 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 7 pages

Page 2

1.0 Introduction:

Biowater Designs Pty Ltd, in accordance with AS/NZS1547-2012 ( Domestic Wastewater Management ) and the
Queensland Plumbing & Wastewater code (QPW) 2019 Version 1, was commissioned to undertake a Site & Soil
Evaluation in the Noosa Council at 5 Figbird Ct, Lake McDonald.

The results form the basis of our recommendations for on site wastewater disposal.

Our Site investigation and field work was performed on Wednesday 25th September 2019 after a period of dry weather.

The investigation was undertaken to determine the soil profile and Long Term Acceptance Rate (LTAR) of the site in
order to accommodate a proposed new 5 bedroom dwelling and shed with possible amenities.

NOTE: This evaluation was undertaken at the owner’s request after considerable discussion regarding environmental
issues of this site and preferred design of the Land Application Area.
.
2.0 Site Description:
2.1 Existing Buildings: None

2.2 Site Factors:
The site is an acreage allotment the area is 2.244ha.

The site borders Lake McDonald at the rear. The proposed Land Application Area is at the front of the site and slopes
away from the lake.

The proposed Land Application Area is moderately sloping (5%) to the South-West.

The proposed Land Application Area has fair exposure to sun and wind due to large trees in the owners preferred
location. Area oversized to compensate for fair exposure. Very good nutrient uptake.

Erosion, mass movement or land slip was not observed on this site. Rock outcrops are not evident on this site.

There are no creeks, or bores on this site or adjoining properties within the required setbacks of the proposed Land
Application Area for Advanced Secondary class effluent.

There is a dam and grassed depression towards the rear of the property. Setback requirements under QPW Code for
Advanced Secondary Effluent can be easily obtained.

Ground water was not encountered on this site during our investigation to a depth of 900mm.

There is no fill in the proposed Land Application Area.

Flooding will not occur on this site.

Rain water will transverse this site from adjoining properties during heavy rains.

Concentrated run-off from this property will transverse adjoining properties during heavy rains.

Soils were dry and there is no evidence of soil surface cracking. No evidence of compaction or seepage areas. Salinity
is not evident.

3.0 Soil Investigation:

3.1 Drainage Pattern: Linear Planar
3.2 Method:
Soil Testing for the site was with a hand auger on 25/09/2019 to a depth of 900mm in the proposed Land Application Area.

The existing soils were visual one textually classified in accordance with AS/NZS 1547:2012 Table E1. The soils
were predominately grey/brown in colour. Weakly structured Loamy Sand - Category 2.

Slight coherence; forms a fragile cast that just bears handling; gives a very short
5mm ribbon that breaks easily; discolours the fingers.
Site Classification was conducted by DEQ (Design Engineers Queensland) and give a Slab Type “M” and classification “P”,
due to trees of potential influence. Articulated joints may be required and must be designed by a qualified person.

                                                                                     C Copyright Lance Picton 2019 design & content.   2/8

Page 3

3.3 Soil Classification
                     BORE HOLE #1                                                BORE HOLE #2

 Depth          Texture     Structure    Colour     CAT       Depth         Texture      Structure         Colour   CAT
   0-                                                          0-       Loamy Sand       Weakly            Grey
           Loamy Sand        Weakly      Grey        2                                                              2
  500                                                         500
  500-                                                        500-
           Loamy Sand         Weakly     Grey        2                  Loamy Sand        Weakly           Grey     2
  900                                                         900



  Moist   N       Water     No            Rock      No         Moist    Y      Water     No                  Rock   No



                   Soil Classification Adopted - Conservative Rate due to fair exposure
    Borehole Nos                                                                                     1&2
    Soil Category Adopted                                                                              3
    Indicative Drainage                                                                        Well Drained
    Structure                                                                                       Weakly
    Texture                                                                                    Loamy Sand
    Indicative Permeability P (m/d) as Ksat*                                                        0.5 - 1.5
    Recommended DIR (AS/NZS 1547 / 2012 - Table M1)                                                    4

 4.0 Recommendations:
 4.1 Treatment Facility:
 The on-site treatment facility is to be a Wastewater Treatment System consistently producing Advanced Secondary
 Quality Effluent with a capacity of no less than 10 Equivalent Persons (10EP).

 The owner has indicated their preferred system is the Earth Safe D10 Advanced Secondary (Concrete) system - TPA #
 03/2019. A tall tank and possible riser ring may be required. The chosen systems approvals meet the Effluent Quality
 and Equivalent Person recommendations for this site. Failure to comply may require the system to be removed from
 site.

 All wastewater from the new dwelling and any future amenities in the shed are to be directed to the Wastewater
 Treatment Plant.

 Position of the proposed Land Application Area is shown on the Site Plan. All works must comply with the Qld
 Plumbing and Wastewater Code and be performed by a licenced plumber.


   5.0 Design Calculation
  The serviceable life of the Land Application Area will be compromised if the design flow is exceeded. Any
  proposed changes to the position of the Land Application Area, System Type or House Design will require a
  reassessment of this site. For our calculations we have assessed the design flow as follows:

                                                  Design Calculation
     DIR (mm/d) (secondary quality effluent)                                                    4
     Hydraulic load (lt/day/person) Tank Water / 5 bedrooms                                   120
     Design Flow Q (lt/day)            PE: 8                                                  960
     Design sizing calculation                                                           Ai = (Q)/DIR
                                                                                           = (960)/4
     Disposal area A+B (square metres) AS/NZS1547:2012                                    Min 240m2
     Nominated Configuration (metres)                                                    24m x 10.2m
     A new Advanced Secondary HSTP is required:                                               10 EP

                                                                              C Copyright Lance Picton 2019 design & content. 3/8

Page 4

5.1 Land Application Area Design:

The minimum Land Application Area required is 240m2. 244.8m2 is allocated. 100% reserve area available on this site.

The Land Application Area is situated in a heavily vegetated area at the front of the site.

The preferred method of dispersal is Surface Irrigation via FIXED sprinklers (Wobblers). See typical drawing for detail
page 5.

An area 24m x 10.2m to be set out as shown on the drawing and three (3) rows of seven - (21) fixed sprinklers be
installed. Laterals to be laid on top of the ground and pinned into position. Wobblers to be installed on 400mm risers
and an inline valve installed on each riser to control plumage. Risers must be kept vertically plumb and supported by a
galvanised rod. See drawing for detail.

A three (3) stage indexing valve (K-Rain) to be installed to service each bank of sprinklers alternatively.

Installer is to ensure that a suitable sized irrigation pump is installed in the system to ensure correct operation of the
irrigation area. Min 25m head.

Laterals to be 25mm PN12.5 to provide sufficient flow to operate each bank sprinklers.

In accordance with the Noosa Council stipulated guidelines, the treated effluent must not at any time extend beyond the
approved designated area.

A 120 micron filter is to be installed in the delivery line at the tank. A non-return valve to be installed in the delivery line
after the filter to prevent back flow when servicing the filter. This filter is to be cleaned at every service interval.

The Land Application Area is to be maintained to ensure survival of plants and adequate mulch cover is sustained.

Delivery line (32mm PN12.5) is to be buried a minimum of 200mm and pipework to comply with AS/NZS 1547/2012
and QPW Code.

Two warning signs are to be installed at the land application area.




   6.0 Setback Regulations:

                                                                                 Secondary           Advanced Secondary
     Recommended Separations Distances - Surface Irrigation
                                                                                 Effluent                 Effluent
       Dwellings & recreation areas                                                   10m                   10m
       Water edge of swimming pools                                                    6m                    6m
       Property boundaries, paths & walkways                                       2m uphill             2m uphill
                                                                                   4m down hill          4m down hill
       Top of bank of permanent water course, creek, lake, waterway etc.               30m                  10m

       Bore or Dam for domestic or stock use                                           30m                    10m
       Vertical depth of seasonal water table                                          0.6m                   0.3m
       In ground potable water tank. Note some authorities require 15m                  6m                     6m
       Sub-Surface Irrigation same as above except for;
       Dwelling & recreation areas                                                      4m                     4m

   NOTE: The local government authority may upon considering the public health and environmental risks
   reduce or increase the distances in the above table.
 Regards,




 Lance Picton jp.
 Site Classifier
 QBCC Lic: 1049265
                                                                                     C Copyright Lance Picton 2019 design & content.   4/5

Page 5

           7.0 SITE PLAN.          This plan is site specific for; 5 Figbird Court, Lake McDonald
                                                                                                                                                                            Notes: This report is based on information and
                                                                                                                                                                            plans provided by the owner in addition to the
                                                                                                                                                                            site information at the time of investigation.
                                                                                                                                                                            It does not take into account any event, whether
                                                                                                                                                                            by human intervention and/or by nature that occurs
                                                                                                                                                                            after the date of the site investigation which affects
                                                                                                                                                                            the results and findings contained within this report.

                                                                  Proposed driveway                                                                                         In the event that the site conditions change or
                                                                  (indicative position)                                                                                     the proposed development is altered in any way,
                                                                                                            Earth Safe SC HH                                                this office is to be notified to determine what if any
                                                                                                            D10 (concrete)
                                                                                                            TPA#03/2019
                                                                                                                                                                            affect they may have on this design. Should a
                                                                                                                                                                            re-design be required, further fees may apply.
                                                                                                                   In-ground concrete




                                                                                                      ea
                                                                                                                   water tanks.
                                                     t




                                                                                                    ar
                                                   ur




                                                                                                    ed
                                                 Co




                                                                                                 tat




                                                                                                            18
                                                                                               ge
                                           ird




                                                                                                              m
                                                                                             ve
                                         gb




                                                                                          of
                                       Fi




                                                                                       ge
                                                                                                                      m
                                                                                                                    10

                                                                                     Ed
                                                                                                Filter
                                                                 10                     Bury 32mm
                                                                   .2                   delivery line min
                                                          BH#2          m
                                                                                        200mm
                                                     m




                                                                                                                  Proposed shed
                                                   24




                                                                                    68




                                             5m                                                                   with amenities
                                                                                      00




                                                                                                                  7.5x10m
                                                                                         0




                                                   BH#1
                                             m
                                           11
                                                           Land Application Area
                                                           240m2 Fixed Sprinklers
                                                           See detail below.

                                                   Slope 5%

                                                                                                                  Proposed 5
                                                                                                                  bedroom dwelling



                                                                                5
                                                                              32
                                                                            11



                                                                                                                                     17
                                                                                                                                        80
                                                                                                                                          00




                      Fixed Sprinkler Design
                                                     Wobbler
                                                     Sprinkler
             In-line valves                          Heads
                                   400mm




             to control plumage
             & isolate banks
                                           Min 100mm mulch


                   Galvanized
                                                 Ground level
                   stake



             1.7       3.4
 3.4




                                                                                                                   BH#2                          3 stage                                                        Lake McDonald
                                                                                                                                                 Indexing Valve

                                                                                                                                                                  Valve box
   10.2m




                      BH#1                                                                                                                                        32mm lilac stripe
                                                                                                                                                                  delivery line



                                                                            24m                                                                    IMPORTANT DIRECTION
                                                                                                                                                   Do not install from this design until it is
                                                                                                                                                   Stamped and Approved by the Local Authority.
                                                                                                                                                   Council may make changes to this design as part
                                                                                                                                                   of the approval process. Only install from Stamped
                                                                                                                                                                                                                               N
                                                                                                                                                   Approved Plans and refer to the Approval Permit for
                                                                                                                                                   possible changes.


                                                                                                                                                                                                                                          5/8
                                                                                                                                                                                                C Copyright Lance Picton 2019 design & content.
Biowater Designs Pty Ltd          Plan of:                                          Client:                               This plan to be read in conjunction with the
                                                                                                                                                                             All plumbing works to be performed by a licenced plumber
PO Box 6218                       Lot 3 SP 266744                                   Brendan Bedford                       attached report.
                                                                                                                                                                             and must comply with the Queensland Plumbing &
Mooloolah Valley Q 4553           5 Figbird Ct,                                     Ph: 0439 717 700                      The proposed Land Application Area must be
                                                                                                                                                                             Wastewater code. LAA setbacks must comply with
Ph: 07 54 947 620                 Lake McDonald                                                                           installed and positioned as per this plan.
                                                                                                                                                                             QPW Code as setout on page 4 of this report.
M: 0407 887 321                                                                                                           Construction of any permanent structures
                                                                                                                          within the designated area is prohibited.
Site Classifier:                                                                                                                                                             SCALE:                           Site Area: 2.244ha
                                  Local Authority:                                     Date:                              Care must be taken to ensure no traffic or fill
Lance Picton jp                                                                                                                                                              Site Plan:   1:1000 @ A3         LA A: 244m2
                                  Noosa Council                                        26/09/19                           in the designated area during construction.
QBCC Lic 1049265

Page 6

Contour Plan




               6/8


[OCR of page images]
 

f—
Contour Plan

 

 

j Z
| le

 

4 ousz Number
ay olPian Numte
47 Food Labels
Az “selor
AZ nleounscioe
Ag “Mirar
@ cuncue
Ag Geeteur abe
V4 Contoure Cis
& Sase
 atd Parcels
ZZQq Tasserverit
Clereanamt
AVY cacel Goveerrieil Areas
AZ Noosa
SL) Orne LGA

 

 

 

 

 

 

 

31/07/2019 (
1:2257

 

 

 

6/8

 

Page 7

7/8


[OCR of page images]
DESIGN
ENGINEERS
QUEENSLAND

   

SITE CLASSIFICATION REPORT
Client: Ausmar Homes Job No: 19.2841 Revision: -

Date of Report: 12th August 2019
Address: LOT 3 (#5) FIGBIRD COURT, LAKE MACDONALD

 

SITE CLASSIFICATION

Classification: P
Due to trees of potential influence
Slab type: M
ys (mm): 20-40
In accordance with AS2870-2011

WIND CLASSIFICATION

N3
In accordance with AS4055-2012

 

This is a preliminary site investigation for Ausmar Homes use only. This report is for internal costing purposes and not suitable for
design purposes or council submission as specific details of the intended build have not been received at the time of this report.

 

#5 Parkview Street, Milton 4064 PH: 33670211 Email: [email protected]
DEQ Consulting Pty Ltdt/a ABN 53 065 711 248

718

Page 8

Illustration Only: Articulated Plumbing Joints




                                                 8/8


[OCR of page images]
 

 

Illustration Only: Articulated Plumbing Joints

 

4

 

(At Tot

I Tit

a

 

 

4
|

 

 

 

 

 

AS35005 2012
410 Note drains shoud be

 

 

Tit

 

 

All Lagging = 40mm thick in Hor Glass sol
@ per AS 2870-2011 Cause 56.4 (@)

 

EXPANDA Jaints on al
horizontal Drains to hep
mantan he pipe ine.
(Cade: DW 100150)

 

 

 

 

 

 

 

 

 

 

 

 

located externally to tre building
wherever practcstie.

 

 

 

 

 

SWIVEL JOINT
(with 50mm Expansion)
protectan

 

 

 

 

 

Trraededdddde ta
a ae ee a Sis
eS See ee ees ii

 
 

 

 

PuPS eR A SaaS
PSST PSPS eee
Pree ere ee ney

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

mfertoStrm ics Te te c on fow

Y= 45 deg fer Fien CLAYS Ormwing No.SP 101A LAGGED PIPEWORK ON 45 Deg SYSTEM |_NOT DRAWN TO SCALE

W y-meg eeu sou Class E - stip Footings with stumps or pads
For tats deteton Ca 75 + mm Differential Movement |
see Causa gure 4152 AS 2870-2011 | Seekental Excanalcne attest nesctive Safle, C erorm *)
_ : COMPANY STORM PLASTICS (SA) Pty Lid PLA Ores Wess

Merten e wre = guny syaien cosind GRADE 140 250mm Fall in 10 Mtrs) ay or
sae oma | cua | Poly Vin Corde PVC | May 2014v2| oP ©

 

 

8/8

 

 