5.1 Land Application Area Design:
The minimum Land Application Area required is 240m2. 244.8m2 is allocated. 100% reserve area available on this site.
The Land Application Area is situated in a heavily vegetated area at the front of the site.
The preferred method of dispersal is Surface Irrigation via FIXED sprinklers (Wobblers). See typical drawing for detail
page 5.
An area 24m x 10.2m to be set out as shown on the drawing and three (3) rows of seven - (21) fixed sprinklers be
installed. Laterals to be laid on top of the ground and pinned into position. Wobblers to be installed on 400mm risers
and an inline valve installed on each riser to control plumage. Risers must be kept vertically plumb and supported by a
galvanised rod. See drawing for detail.
A three (3) stage indexing valve (K-Rain) to be installed to service each bank of sprinklers alternatively.
Installer is to ensure that a suitable sized irrigation pump is installed in the system to ensure correct operation of the
irrigation area. Min 25m head.
Laterals to be 25mm PN12.5 to provide sufficient flow to operate each bank sprinklers.
In accordance with the Noosa Council stipulated guidelines, the treated effluent must not at any time extend beyond the
approved designated area.
A 120 micron filter is to be installed in the delivery line at the tank. A non-return valve to be installed in the delivery line
after the filter to prevent back flow when servicing the filter. This filter is to be cleaned at every service interval.
The Land Application Area is to be maintained to ensure survival of plants and adequate mulch cover is sustained.
Delivery line (32mm PN12.5) is to be buried a minimum of 200mm and pipework to comply with AS/NZS 1547/2012
and QPW Code.
Two warning signs are to be installed at the land application area.
6.0 Setback Regulations:
Secondary Advanced Secondary
Recommended Separations Distances - Surface Irrigation
Effluent Effluent
Dwellings & recreation areas 10m 10m
Water edge of swimming pools 6m 6m
Property boundaries, paths & walkways 2m uphill 2m uphill
4m down hill 4m down hill
Top of bank of permanent water course, creek, lake, waterway etc. 30m 10m
Bore or Dam for domestic or stock use 30m 10m
Vertical depth of seasonal water table 0.6m 0.3m
In ground potable water tank. Note some authorities require 15m 6m 6m
Sub-Surface Irrigation same as above except for;
Dwelling & recreation areas 4m 4m
NOTE: The local government authority may upon considering the public health and environmental risks
reduce or increase the distances in the above table.
Regards,
Lance Picton jp.
Site Classifier
QBCC Lic: 1049265
C Copyright Lance Picton 2019 design & content. 4/5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.