Building Height
9. The maximum height of the development must not exceed 10 metres above ground level.
Building Appearance
10. The development must be finished with subdued external building colours.
11. All mechanical equipment and other service infrastructure located on the site must be:
a. Located not less than 2 metres from a property boundary; and
b. Fully enclosed or screened such that they are not visible from the street frontages nor
adjoining properties. Where screened by landscaping, landscaping beds must be at
least 1.5 metres wide.
12. All waste storage areas must be screened from the street and adjoining property by buildings,
landscaping or fencing.
Emissions
13. The development must contain any odour and/or dust air pollutants within the boundaries of
the site.
Landscaping
14. The development site must be landscaped. The works must be undertaken in accordance
with the Operational Works approval and Planning Scheme Policy PSP2 - Landscaping and
must include in particular:
a. the works shown on the Approved Plans;
b. vegetated screening of any electrical transformers, bin storage areas and the like from
the road frontage; and
c. provision of 3 street trees within the road reserve.
15. Any street fencing must not exceed 1.8 metres in height. Any fencing on the front boundary
must either:
a. not exceed a maximum height of 1.8 metres; and
b. be of open construction.
15. All landscape works must be established and maintained in accordance with the approved
design for the life of the development, and in a manner that ensures healthy, sustained and
vigorous plant growth. All plant material must be allowed to grow to full form and be
refurbished when its life expectancy is reached.
Fencing and Walls
16. The rear and side boundaries of the site are to be enclosed with security fencing no less than
1.8 metres in height.
Mechanical plant, equipment and storage
17. Mechanical plant and equipment are to be fully enclosed or screened and visually integrated
into the line and plane of the building and roof design and must not project beyond the height
or width of the building when viewed from the street and adjoining properties
Water & Sewer Connections
18. An underground connection to reticulated water and sewerage must be provided to the
development site in accordance with the standards and requirements of Northern SEQ
Distributor–Retailer Authority (Unitywater).
19. A Certificate of Completion from the Northern SEQ Distributor–Retailer Authority (Unitywater)
must be submitted to Council that certifies an underground connection to reticulated water
and sewerage has been provided to the development site.
Page 3 of 14
Document Set ID: 22526729
Version: 4, Version Date: 02/08/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - Minor Change - MCU20 0159 01 & OPW20 0245 01 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 194 KB (small file)
- File type
No other editions are linked here.