Council archive · source document
geotech and slope stability · MCU22/0145
PROPOSED UNIT DEVELOPMENT
3 HENDERSON STREET, SUNSHINE BEACH
4.4 Subsurface Conditions
Detailed descriptions of the subsurface conditions encountered in the boreholes are provided in the
borehole reports attached in Appendix A, along with definition sheets which describe terms and
abbreviations used in the reports. The subsurface conditions encountered in the boreholes are summarised
as follows:
Asphalt (borehole BH1 only) – about 20 mm thick; then or from the ground surface
Fill – comprising very loose to loose gravelly/silty sand to depths between 0.3 m and 0.7 m BGL;
overlying
Aeolian Sands – comprising mostly poorly graded sands that were loose to depths of between 1.1
m and 2.8 m BGL; then becoming medium dense and increasing to dense below depths of about
4 m BGL.
Table 1 below summarises the subsurface profile in each borehole.
Table 1: Summary of Subsurface Profiles
Very
Medium Dense
Borehole No. Asphalt Fill Loose/Loose Dense Sand
Sand
Sand
BH1 0 – 0.02 0.02 – 0.3 0.3 – 1.1 1.1 – 4.0 4.0 – 6.0TD
BH2 NE 0 – 0.7 0.7 – 2.8 2.8 – 4.0 4.0 – 5.5TD
Notes: 1. Depths noted in m BGL at time of investigation (9 June 2022)
2. NE denotes not encountered
3. TD denotes borehole termination depth
4.5 Groundwater
No signs of groundwater seepage (‘springs’) were observed during our walk-over. Groundwater was not
encountered in the boreholes at the time of investigation. Groundwater conditions are expected to be
reflective of prevailing weather conditions and seepage may develop particularly following periods of
prolonged or heavy rainfall.
4.6 Surface Drainage
Surface drainage would be expected to follow natural surface contours to the south-east towards
Henderson Street, thus draining into the roadside drainage system. It is noted that the site has a small
catchment immediately upslope. However, most runoff from upslope of the property is anticipated to be
intercepted by the existing stormwater infrastructure associated with the neighboring structures and
roadside drainage systems.
Given the sandy nature of the site, rainfall would normally be anticipated to infiltrate the ground surface.
However, as the proposed development will occupy a large part of the block, significant run-off from hard
surfaces will occur. Nevertheless, where directed into swales rather than pipes, such run-off would be
expected to infiltrate into the natural sands relatively rapidly. No significant surface run-off features were
noted during our assessment (e.g. deep rilling or scour/wash out scars). This indicates that significant
overland flow is generally absent during rainfall events. Recommendations to improve surface drainage as
part of the development works are provided in Section 6.5.
29 June 2022
Report No. 22227-001-Rev0 5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.