0
B ROADS AND SERVICES WITHIN LIMIT OF WORKS AND REMOVE FROM SITE
.8
8
9R
46
.4 4R
1
47 .2
T
45 .83 U.N.O.
53
RT 44
LOCATION AND EXTEND OF EXISTING
.4
.71
6R
46 RB
F
ELECTRICAL CONNECTION TO BE CONFIRM RB
52
47
9 .53 11. WHERE NECESSARY, CONTRACTOR SHALL OBTAIN ALL NECESSARY
.3
45
.3
.5
6R
5
ON-SITE. REMOVAL AND REPLACEMENT TO 47
F
.17 APPROVALS TO CARRY OUT SERVICES RELOCATION OR ALTERATIONS.
BE ARRANGED BY SITE SUPERINTENDANT 47 RT CP
46 .84
53
RT .86
46
46
.7
.1
47
47
B
4
9.
7R
B 6 R
.10
BUP3585
.6
4 7R .3
F
47 46
1
.5 T
47 00R EXISTING BUILDING
47
.
.6
4 9 TO BE DEMOLISHED RT .78
0
3 .87 45
7.3 46 B
4
.90 .64R
46 46
OE RT
0
RT 49.8
. 83
49 4
.8
49
49
.51
49
.3 2 T
49 .86R
.9
47
.8
59
2
0
49 7.
4 .17 .98 LEGEND:
52
1 47 46
OE
.3
.6
7R
47
F
4
.6
47 EXISTING CONTOURS
49
.82 55 .60
53
87 49 .
.9
. RT 47 47
.4
EXISTING 49
6
6
87 .55
RF
49. 2 47
TELSTRA PIT .9 .33 EXISTING BUILDING
49 47
B
3R
OE
49
4 RT .6
.6 47 EXISTING KERB AND CHANNEL
.17
.9
47
0
48
85
9.
49
4
.93 .60 EXISTING FENCE
49
.9
49 47
RB
6
.94
.73
47
49
W EXISTING TELSTRA
0 T
.6
49.97 .8
49
49.92 49
5
4
.6
.9
49 RB
7
49
49.71
.79
.7
49
.92 47 OE EXISTING OVERHEAD ELECTRICAL
OE 9
.7
49
7T
W
K
49.6
8 W EXISTING WATER
49
.6
6
49.68 RB
.01 S EXISTING SEWER
48
49
W F
.88
49
90 7R
.61
. 47
.9
49 .3
1C
52
EB
.90
EXISTING TREE
R
7
.7 49
49 RT .13
W .81 48 EXISTING TELSTRA PIT
49
CP
OE
49
.54 RT
E B 49
.50 . 81
SP193676 WM EXISTING WATER METER
49
RT
W RB .81
.49 49 ADJACENT BOUNDARY
49
49
RB
.15
.48
8
49
.4 49
EB
PROPOSED BOUNDARY
49
W .95
.5
48
5C
R
0
.4
49
49
.33
W .25
OE
49
EB
49.24
.07
49
W
.17
49
49
.08
EB
OE
49
.18
CR
.3 3
49
FD
North Point Approved Project Address Sheet Title
E WHITMORE
N RPEQ 31423
51 ELANDA STREET SUNSHINE BEACH QLD
EXISTING LAYOUT PLAN
For and on behalf of RECOR Pty Ltd.
Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 26/09/25 ISSUE FOR OPW APPROVAL DP AY
1 0 1 2 3 4 5
www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE A1
A 21/03/25 ISSUE FOR APPROVAL TVZ AY SCALE (metres) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
1 : 100 (FULL SIZE) drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK in the revision description. 20240127 003 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
REPS - Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.