Original source · versioned page text
Attachment 5 - Servicability Report.pdf
NOOSA CITY PLAN - WATER QUALITY AND DRAINAGE CODE Job Ref No.: 22159
Performance Outcomes and Acceptable Solution
Table 9.4.8.3 – CRITERIA FOR ASSESSMENT
PO16 AO16
On-site effluent treatment and disposal An onsite effluent system and disposal
systems are designed, constructed and area is: N/A
managed to not comprise the (a) not located on a slope greater
environmental values of waters and than 1 in (10%)
water quality objectives. (b) not located at or below the 1%
annual exceedance probability
Note—Prescribed water contaminants (AEP flood event);
are defined in the Environmental (c) Not located within a riparian
Protection Act 1994. buffer area mapped on a
Biodiversity, Waterways and
Note—Compliance with the performance Wetlands Overlay Map; and
outcome should be demonstrated by the (d) Setback 400 metres minimum
submission of a site-based stormwater from the full supply level of
management plan for high-risk Lake Macdonald.
development only.
Editor’s Note—The Plumbing and
Drainage Act 2003 sets out
requirements for onsite effluent
treatment and disposal. The
Queensland Plumbing and Wastewater
Code and associated guidelines are
used to confirm the suitability of each
site to accommodate an onsite
sewerage facility; or where a centrally
located group collection treatment
system is proposed, confirmation as to
the suitability of the designated site to
accommodate the onsite sewerage
facility. Additionally, where the
combined total peak design capacity of
effluent treatment is less than 21
1. Solution: PO = Performance Outcome
A/O = Acceptable Outcome
N/A = Not applicable to this proposal
Noosa Civic Village Mixed Use Development, Noosaville
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Attachment 5 - Servicability Report.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.