Council archive · source document
A1-01 Existing Site Plan · OPW18/0027
Attached to the e-mail Operational Works Application OPW18/0027 - 51 The Quarterdeck Noosa Heads - Driveway Application.
Plans and drawings: the text below has words only, no drawings.
Lot Descrip
SITE on
COVERAGE Legend Final loca on of walls, gardens, paved Sewer line loca on to be confirmed by builder on site prior
ZONED R20 86 areas TBC. on site by builder/client to construc on of pool and/or proposed dwelling
Lot : Pool Water Exposed Aggregate Gravel/Stone Garden Beds
% ALLOWED
Plan : 50%
RP 88934 Sediment control measures to be Pool fencing and gates in accordance with local authori es
SITE: AREA
Area 506.00m2 taken on site during construc on regula ons + A.S. 1926.1 Loca on TBC. on site by builder/client
SITE COV.
Parish : AREA WEYBA2
245.70m Timber Deck Tiles/Paving Concrete Lawn
County : MARCH Final loca on of site drains to be All stormwater drains to be 100mmØ UVPC sealed system in
SITE COV. =48.6% confirmed on site by builder/client accordance with A.S. 3500.3 To disperse 170m2 max. roof area
Table of Content
Sh No: Layout Name Scale
01 Exis ng Site Plan 1:200
01 Sub Level Overhang Calcula ons 1:100 DASHED LINE + FILL REPRESENTS EXTENT OF 'LAND SUBJECT TO LANDSLIDE REMOVAL OF EXISTING SITE TREE BY OTHERS -
GREY FILL REPRESENTS NOM SEWER HAZARD AREA' AS PER DEPARTMENT OF INFRASTRUCTURE, LOCAL TREES TO BE REMOVED PRIOR TO CONSTRUCTION
02 Proposed Site Plan 1:200 ZONE OF INFLUENCE. BUILDER TO GOVERNMENT AND PLANNING DA MAPS OVERLAY. BUILDER & ENGINEER TO
AVOID WORKS WITHIN THIS ZONE ENSURE MEASURES ARE IN PLACE TO PREVENT STRUCTURAL DAMAGE TO (BUILDER/CLIENT TO CONFIRM TREES TO BE
03 Proposed Site Plan BUILDINGS AND STRUCTURES WITHIN ZONE. REMOVED)
04 Sub Level Floor Plan 1:100 SEWER LINE LOCATION TO BE CONFIRMED LAND SUBJECT TO BUSHFIRE POTENTIAL IMPACT
ON SITE PRIOR TO CONSTRUCTION OF BUFFER AREA. CONFIRM COMPLIANCE
05 Mid Level Floor Plan 1:100 POOL AND PROPOSED DWELLING
LOT 87 REQUIREMENTS WITH THE PRIVATE CERTIFIER
PRIOR TO COMMENCEMENT
06 Upper Level Floor Plan 1:100 APPROXIMATE HOUSE
EXISTING TIMBER
AND GI HOUSE
CONNECTION PLOTTED FROM DATA PLOTTED FROM AXIS SURVEY (JOB NO.
07 Sub Level Dimension Plan 1:100 STATUTORY RECORDS APPROX. 1683086 DATED 15.11.16)
INVERT LEVEL 73.69m DATA TO BE CONFIRMED PRIOR TO
APPROX. 0.65 DEEP CONSTRUCTION BY BUILDER
08 Mid Level Dimension Plan 1:100 33.535
THE QUARTERDECK
77.50 SEWER M/H
09 Upper Level Dimension Plan 1:100 RL 75.62 EXISITNG TIMBER FENCE 00° 02' 00" EXISITNG TIMBER FENCE
1,500
2,000
10 Eleva on 01 1:100 75.75
2,500
11 Eleva on 02 1:100
12 Eleva on 03 1:100 76.00
90° 02' 00"
7.801
13 Eleva on 04 1:100 1,500
76.25 2,000
14 Sec on 01a 1:50
2,500
270° 02' 00"
16.134
15 Sec on 01b 1:50
76.50 6,000
16 Sub Level Slab Plan 1:100
POWER POLE
LOT 85
TELSTRA
#51955
17 Mid Level Slab Plan 1:100
76.75 EXISTING
18 Hardscape Plan 1:100 RENDERED BRICK
AND GI HOUSE
19 Roof Layout 1:100
77.00
0
20 Sub Level Reflected Ceiling 1:100
00
6,
EXISITNG BLOCK RETAINING
21 Mid Level Reflected Ceiling 1:100
0
77.25
50
1145° 0
4,
.7 2' 00
22 Upper Level Reflected Ceiling 1:100
6,000
0
82 "
00
3,
77.50
4,550
23 Mid Level Window Layout 1:100 DOTTED LINE REPRESENTS
MINIMUM BUILDING SETBACK AS
3,000
24 Upper Level Window Layout 1:100 PER COUNCIL RELAXATION - REFER
77.75 COUNCIL DOCUMENTS 26/05/17
25 Sub Level Services Plan 1:100
26 Mid Level Services Plan 1:100 78.00 25.202
00° 02' 00"
27 Upper Level Services Plan 1:100 78.25
28 Primary Driveway Crossover 1:50 78.50 POWER POLE
#51956 POWER POLE
29 Secondary Driveway Crossover 1:50 TBM NAIL IN KERB #51957
AHD RL 78.402m
30 Perspec ve Views NTS
31 Perspec ve Views NTS 78.75
32 Perspec ve Views NTS
79.00
TBC ON SITE
THE QUARTERDECK
01 Exis ng Site Plan
1:200
TREES TO BE REMOVED
TREES TO REMAIN
Revision Notes. Project Client Drawing Date Author
reitsma
Issue C - 20/02/2018 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all relevant geographical/wind Topovsek Residence Planet Homes Qld Exis ng Site Plan 20/02/2018 JTL/MM
Proposed Tree removal plan All dimensions, bearings, exis ng services, mandatory council category requirements. All cut and fill ba ers are indica ve only and must be
restraints/requirements and proposed levels are to be checked and verified established and verified by builder/client in rela on to proposed slab and/or floor
on site by builder/client prior to commencement of works. Any levels Builder Scale Revision
Lot 86 (#51) The Quarterdeck 1:200 C
N
discrepancies must be communicated to the designer prior to These drawings are to be read in conjunc on with other relevant consultants
+61 7 5491 6834 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and signed drawings and reports.
Caloundra contracts to take precedence over all Reitsma documenta on. NOOSA HEADS Stage Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia © Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767 QBSA Lic. No. 65652 BDAQ Member
Qld 4567 P: 54 50 5157 M: 0438 152 508 WORKING DRAWINGS 4378 1 /32
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
A1-01 Existing Site Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 618 KB (small file)
- File type
No other editions are linked here.