Council archive · source document
Approved Plans MCU14-0084.03 · MCU14/0084.03
Plans and drawings: the text below has words only, no drawings.
Very large file (34.5 MB): may take a few minutes to open.
Original PDF page 9, section 1. The text section number identifies this passage in the reader.
-
NOOSA COUNCIL
APPROVED PLAN ADJOINING PROPERTY HOUSE DASHED IN RED
MCU14/0084.03 5 MAR 2018
OUTLINE OF LANDSCAPED DOME AS
METAL ROOF FOR CONDENSERS PER GIA APPROVED SCHEME OPAQUE ALUMINUM
RETAINING WALL AND SPLIT FACE 19.10.2015 SHOWN IN RED BALUSTRADE
SOLAR ARRAY OVER DRIVEWAY IN A BLOCK TO DRIVEWAY WALL &
PERGOLA STRUCTURE BOUNDARY EDGING GREEN ROOFS POOL DECK
OUTLINE OF ROOF PARAPET AS PER
GIA APPROVED SCHEME 19.10.2015
TIMBER POSTS
SHOWN IN RED
BLOCK WALL
52550 _ROOF
SOUTH-WEST BOUNDARY
5
1 : 100
METAL ROOF FOR CONDENSERS STEEL EDGE TO LANDSCAPE MOUND
OUTLINE OF LANDSCAPED DOME AS
PER GIA APPROVED SCHEME
SOLAR ARRAY OVER DRIVEWAY IN A 19.10.2015 SHOWN IN RED
PERGOLA STRUCTURE GREEN ROOFS
OUTLINE OF ROOF PARAPET AS PER VENT GRILLS TO DRY ZONE
GIA APPROVED SCHEME 19.10.2015
SHOWN IN RED LOCKABLE GARAGE DOORS
ADJOINING PROPERTY
DASHED IN RED
52550 _ROOF
HOUSE
BOUNDARY
OPAQUE ALUMINUM
BALUSTRADE 49550 _LEVEL 02
POOL DECK SOLAR ARRAY
SOUTH-WEST
PERGOLA 2
1 : 100
LANDSCAPE TRELLIS
STRUCTURE
53150 6 OUTLINE OF ROOF PARAPET
AND LANDSCAPED DOME AS
PER GIA APPROVED SCHEME
52550 _ROOF 19.10.2015 SHOWN IN RED _ROOF 52550
51250
METERS, STORE & REFUSE BINS ENCLOSURE
49550 _LEVEL 02 _LEVEL 02 49550
SOUTH (DRIVEWAY)
4 LANDSCAPE MOUND PLANTED WALLS & ROOFS, REFER TO LANDSCAPE DRAWINGS SAFETY/FALL PREVENTION
1 : 100 PLATFORM. EITHER TIMBER
FLOOR WITH VERTICAL
REFER TO LANDSCAPE DRAWINGS TIMBER BATTENED
BALUSTRADE, OR NETTING
INSTALLATION.
FRAMELESS GLAZING POOL FENCE
STAIR TO POOL PLANT _LEVEL 01 45000
ADJOINING PROPERTY SCREENED SPA HEATER
DASHED IN RED
_BASEMENT 40800
RL 39600
SOUTH
OPAQUE
LANDSCAPING
1 BALUSTRADE/FENCING _POOL PLANT 37550
1 : 100
POOL DECK
6
BOUNDARY
OUTLINE OF ROOF 6
PARAPET AND
LANDSCAPED DOME AS
PER GIA APPROVED _ROOF 52550
SCHEME 19.10.2015 SHOWN
IN RED
aproximate
1850 -TBC
_LEVEL 02 49550
SOUTH BOUNDARY
3
1 : 100
REV. DATE DESCRIPTION DRAWN CHECKED
CLIENT
Universal Property Company Establishment
7/02/2018 2:21:50 PM 0 2 4 6 10m
T
M
QUALITY CERTIFIED ISO 9001
Completion of the Drawing Status is evidence that the
design has been
verified as confirmed to the requirements of the Project
1
2
04/05/2016
31/8/2016
-------------
NEW LIFT AMENDMENT
ND
ND
NR
NR
DA REVISION Brisbane address
GROUND LEVEL
283 ELIZABETH ST
BRISBANE 4000
Scale 1:100
M.S. Plan. 3 21/03/2017 ISSUE FOR CONSTRUCTION ND NR
Copyright Noel Robinson Architects Pty Ltd AUSTRALIA
4 13/07/2017 POOL, SOLAR, COLUMN, GLASS, DOORS, SAUNA ND NR
Initialing the "Drawn By" box confirms that this drawing has PROJECT
71 SEAVIEW TERRACE Drawn by ND Checked by NR
been prepared
in conformity with Noel Robinson Architects' M.S.
5
6
21/07/2017
07/02/2018
DA REVISION
SETBACK RELAXATION APPLICATION & PARTIAL PC NR
architects postal address
GPO BOX 353
procedures.
This drawing is protected by copyright. All rights reserved. Unless permitted under the Copywright Act 1988, no part ROOF RAISE 81.269.B13 planners BRISBANE SCALE 1 : 100 A1
of this drawing may in any form or by any means be reproduced, published, broadcast or transmitted without prior
written consent by the copyright owner. interiors QUEENSLAND 4001
AUSTRALIA
SCALE 1 : 200 A3
If the status of this drawing is not signed off For Construction it may be subject to change, alteration or amendment TITLE tel +61(0)7 3229 5266
at the discretion of Noel Robinson Architects PtyLtd. If so, Noel Robinson Architects Pty Ltd is not liable for any
loss, damage, harm or injury whether special, consequential, direct or indirect, suffered by you or any otherperson
as a result of your use of this drawing for construction purposes.
SOUTH & SOUTH-EAST ELEVATIONS Noel Robinson Architects Pty Ltd
ABN 62 323 175 502
fax +61(0)7 3221 0796
[email protected]
www.nrarc.com
14/08/2017
Date
ACN 010 011 720
DWG NO. NRA-81269-CD_0440 REV. 6
Use figured dimensions only. Do not scale. Verify all dimensions on site. Reportany discrepancies to the Architect [Note. CAD drawings are uncontrolled drawings]
for decision before proceeding with work. \\nrasrv01\RedirectedFolders\pcain\Documents\CF-81269-PROJECT042_pcain.rvt
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans MCU14-0084.03.pdfRelated documentApplication case desk ↗
About this file
- File size
- 34.5 MB (very large file)
- File type
No other editions are linked here.