                                                                                     SWMS:07 – Excavation & Trenching

Project Details
Project:                                71 SEAVIEW TCE SUNSHINE BEACH QLD 4567                                                      Responsible Person:          Matt Leeke 0414 691 314
                                                                                                                                    Site Manager:                Matt Leeke 0414 691 314
                                                                                                                                    Site Foreman :               Terry Strahan 0419 762 427
                                        Performing various work activities associate with Excavation and Trenching                  Site Foreman :               Jesse Joyce 0403 745 840
Activity Description:
                                        Activities                                                                                  HSO:                         Terry Strahan 0419 762 427
                                        SWMS 04 – SWMS 06 – SWMS 08
Referenced SWMS:
                                             Earthmoving equipment: Excavator , Back Hoe , Bob Cat , Front End Loader , Roller , Other:
Plant and Equipment Involved:
                                             Shovel and hand tools
                                                                                                                                                                    energised electrical installations
                                        Work at Heights >2m                   Disturbance of asbestos                    Confined spaces
                                                                                                                                                                    or services
High Risk Activities:                                                          Structural alterations requiring          Excavation >1.5 metres or near a           a contaminated or flammable
                                        Demolition of a structure
Carried out in or near the following:                                          temporary support                         tunnel                                     atmosphere
                                        A work area with moving                water or other liquid that
                                                                                                                         tilt-up or precast concrete                Other: ____________________
                                        powered mobile plant                   involves a risk of drowning
PPE Required:                           Hard Hat                      Safety glasses / goggles           Hearing Protection                Fall Arrest Harness              Disposable overalls:
(Tick as relevant)                      Safety Boots                  Face Shield                       Gloves                             Respirator                       High Visibility Vest
                                           Daily inspection of the trench for stability and factors that may affect the stability of the trench at the start of every day and before each entry
Maintenance / Prestart Checks
                                            into the trench.
Required:
                                           Pre-start inspection of mobile plant
                                           Inspection and maintenance of mobile plant as per manufacturer requirements
                                            Geotechnical Engineer qualifications
Certificates of Competency
Required:                                   Certificate(s) of Competency for operation of particular mobile plant

                                             Certificate(s) of Competency for operation of particular mobile plant and dogging work (where relevant)
Training / Competencies Required:
                                             Induction into this SWMS
                                             General Safety Induction
                                        Work Health & Safety Act 2011                                                       Mobile Crane Code of Practice 2006 - QLD
Health, Safety or Environmental                                                              Codes or Standards
                                        Work Health & Safety Regulation 2011, Part                                          Excavation Work Code of Practice 2013 – QLD
Legislation:                                                                                 Applicable to the Works:
                                        13.1, Division 11                                                                   Excavation Work Code of Practice 2014 – NSW
                                        VIC OH&S Regulations 2007, Section 5.1.26                                           Excavation Work Code of Practice 2012 – TAS
                                                                                                                            QLD, NSW & TAS Code of Practice – Managing risks of plant in
                                                                                                                            the workplace 2013
                                                                                                                            VIC Code of Practice(no.19) – Plant 1995
584 Milton Road TOOWONG QLD 4066                              SWMS Developed by:     Jamie Gilbert                                                                       VERSION 8 – September 2015
P: (07) 3335 5000 F: (07) 3335 5005                           Position:              National HSE Coordinator                                                                               Page 50
ABN: 52 009 778 330

Used in these records

About this file

File size
16.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

WHSMP.pdf · 16.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.