SWMS:09 – Working with Bonded Asbestos Containing Materials – N/A
Safe Work Methods
Responsible Residual
H Controls / Work Methods
Person/s for Risk
Job Steps Potential Hazards L C R O 1. Eliminate 2. Substitute 3. Isolate 4. Engineer Monitor & L C R
C 5. Admin 6. PPE Review
Only unused bags should be used, and bags marked for
asbestos waste should not be used for any other purpose.
The bags should be twisted tightly, folded over and the
neck secured in the folded position with adhesive tape or
any other effective method.
All asbestos waste should then be placed in a solid waste
drum, bin or skip, and / or be removed by a licensed waste
transporter.
The asbestos waste drum or skip should be lined with
0.2mm polythene plastic and have appropriate labels
erected warning of asbestos waste (E.g. DANGER
ASBESTOS – DO NOT BREAK THE SEAL).
Breakage/rupture of asbestos C 3 H 5 Hard and sharp asbestos waste required a preliminary Licensed B D 3 M
waste bag 13 sealing or a protective covering before it is placed in the Class 9
waste bags, to minimise the risk of damage to the bags. Removalist
Asbestos waste bags should not be filled more than half full
and excess air should be gently evacuated from the waste
bag, in a manner that does not cause the release of dust.
All asbestos waste should be double bagged outside the
work area immediately following the decontamination
process.
Decontamination of tools, Inhalation of airborne asbestos B 4 E 5 Use damp rags to clean the equipment and tools used (wet Licensed B D 3 M
equipment, asbestos work fibres 21 wiping) and then dispose of rags as asbestos waste. Class 9
area and PPE Carefully roll or fold any plastic sheeting used to cover any Removalist
surface within the asbestos work area, so as not to spill any
dust or debris that has been collected.
Where the asbestos work area cannot be fully
decontaminated using a wet (wet wiping) or dry method
584 Milton Road TOOWONG QLD 4066 SWMS Developed by: Jamie Gilbert VERSION 8 – September 2015
P: (07) 3335 5000 F: (07) 3335 5005 Position: National Health & Safety Co-ordinator Page 77
ABN: 52 009 778 330
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
WHSMP.pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.