c. indicate the location of loading and unloading areas;
d. indicate the location of any “holding” areas for heavy vehicles;
e. operating hours.
20 Construction staff must not park within the Council carparks in Belmore Terrace, Duke Street,
Webb Road or any other surrounding street. Parking must either be on site or at a suitable
off-site location serviced via a shuttle bus. Details must be included in the Traffic
Management Plans for the site.
Bicycle/Scooter Provision
21 Four bicycle racks (capable of accommodating 8 bikes) and 4 scooter spaces must be
provided on site at the rear of the building. The works must be undertaken in accordance
with an Operational Works approval and clearly shown on the plans for carparking.
Stormwater Drainage
22 The site must be provided with a stormwater drainage system connecting to a lawful point of
discharge. The works must be undertaken in accordance with an Operational Works
approval and must include in particular:
a. Connection of any new works on site and in the carparking area to the existing
stormwater drainage system;
b. The works in Webb Road must be generally in accordance with drawing number
16636-SK01 Revision A prepared by TOD Noosa and include sufficient detail:
i. To quantify the catchment and calculate runoff to the proposed inlet and define
overland flow component bypassing the inlet in a 1% AEP event
ii. To demonstrate improved inlet capture
iii. To demonstrate how the adjacent 1in 4 fill batter is to be stabilised to avoid scour
when flows bypass the proposed inlet
iv. To demonstrate that cars parked in the adjacent carparking spaces will not be
flooded in a 1% AEP event
Geotechnical Stability
23 All works must be carried out in accordance with a Geotechnical Report (or part thereof)
prepared by a qualified person* and endorsed through an Operational Works approval.
*(Refer to Advisory Note)
24 Certification must be submitted to Council from a qualified person* which certifies that the
development has been constructed in accordance with the Geotechnical Report for the
development and that the development has a minimum factor of safety against landslip of
1.5 in the long term.
*(Refer to advisory Note)
Earthworks and Retaining Walls
25 All fill and associated batters must be undertaken in accordance with an Operational Works
approval, and contained entirely within the subject site unless written permission from the
respective landowner(s) is provided to Council.
26 All retaining walls must be designed and constructed in accordance with the planning scheme
and must be certified by an RPEQ where exceeding 1.0m in height. All retaining walls that
are publicly accessible and exceed 1.0m in height must be fitted with a commercial grade
safety fence.
Damage to Services and Assets
27 Any damage caused to existing services and assets as a result of the development works
must be repaired at no cost to the asset owner at the following times:
Page 7 of 11
Document Set ID: 23410782
Version: 3, Version Date: 20/12/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Minor Change Existing Approval MCU17 0024 02 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 191 KB (small file)
- File type
No other editions are linked here.