Engineering Letter TSSC214004

of 3

Page text shows just the words. Original shows the document exactly as it was published.

                                                                                                                     Steelx Building, 3rd Floor
                                                                                                                     2 Boston Court
                                                                                                                     Varsity Lakes, Qld 4227
                                                                                                                     Australia
                                                                                                                     Phone: +61 7 5657 4456
                                                                                                                     Fax: +61 7 5657 8899

24 August, 2021

To whom it may concern

This certification has been completed based on the purchaser's advice of the building's intended purpose.
Any approving authority should confirm that the Importance Level nominated is appropriate for the building's usage as this is not able
to be ascertained by the engineer.

I certify that I am an independent technical expert and have reviewed Steelx Shed Management System Software that has produced the
design and drawings detailed below. I have reviewed the documents based in the site specific analysis produced by the Shed Safe
Sitecheck Software (Refer to the Site Specific Design Criteria Analysis) :


         Job Number:          TSSC214004                                                 Design Criteria: Building Class 10,
         Customer:                                                                       Max Design Wind Speed of 46.5m/s
         Address:             9 Rules Rd Pomona QLD 4568
                              Australia (-26.37313 and 152.85327)


 Drawing Number                    Date                         Number of Pages                     Description
 TSSC214004 - 2                    24/08/2021                   1                                   General Notes
 TSSC214004 - 3                    24/08/2021                   1                                   Layout
 TSSC214004 - 4                    24/08/2021                   2                                   Specification Sheet
 TSSC214004 - 5                    24/08/2021                   1                                   Bracing
 TSSC214004 - 6                    24/08/2021                   1                                   Concrete Piers
 TSSC214004 - 7                    24/08/2021                   1                                   Slab Dimensions
 TSSC214004 - 8                    24/08/2021                   5                                   Connection Details
 TSSC214004 - 9                    24/08/2021                   1                                   Flashing Fixing Details
 TSSC214004 - 10                   24/08/2021                   4                                   Purlin And Girt
                                                                                                                     (Some drawings have multiple pages, eg: "1 of 3".)


As an independent technical expert, I verify this design complies with the following codes and standards:


                         NCC:2019 Volume 2 Amendment 1                                AS/NZS 4600:2018
                         AS/NZS 1170.1:2003                                           AS/NZS 1170.2:2011
                         AS/NZS 1170.3:2002                                           AS 4100:1998
                         AS 2870:2011                                                 AS 3600:2018

Unless nominated, the building has not been designed for any additional loads including, but not limited to, earthquake, snow, solar
panels or lining with any materials.

Signed




John Ronaldson
for and on behalf of
Apex Engineering Group PTY LTD
ACN 632 588 562

Member Institution of Engineers (Aust.), CPEng (NER Structural) Regn. No. 5276680
Registered Professional Engineer (Structural) - Queensland: Regn. No. 24223
Registered Building Designer & Professional Engineer (Structural) - Tasmania: Regn. No. 185770492
Registered Professional Engineer (Structural) - Victoria: Regn. No. PE0003848




                                                                                                                                                                    /
Log in to download the original file

Engineering Letter TSSC214004.pdf · 324 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 2 pages

Page 2

                                                                   Department of Housing and Public Works
                                                                   Form 15 - Compliance certificate
                                                                   for building design or
                                                                   specification
                                                                                                                        Version 4 - July 2017
NOTE: This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the Building
Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work
complies with the BCA or a provision of the Queensland Development Code (QDC). A building certifier (Class B)
can not give a certificate regarding QDC boundary clearance and site cover provisions.

1. Property description                            Street address (include no., street, suburb/locality and postcode)
This section need only be completed if             9 Rules Rd
details of street address and property             Pomona, Qld 4568
description are applicable.
                                                   Lot and plan details (attach list if neccessary)
E.g. in the case of (standard/generic) pool
design/shell manufacture and/or patio and
carport systems this section may not be
applicable.                                        In which local government area is the land situated?
The description must identify all land the         Noosa Shire Council
subject of the application.
The lot and plan details (e.g. SP/RP) are
shown on title documents or a rates notice.
If the plan is not registered by title, provide
previous lot and plan details.

2. Description of component/s                      Steel framed building and foundations as described in drawings
certified                                          referenced Job# 214004
Clearly describe the extent of work covered
by this certificate, e.g. all structural aspects
of the steel roof beams.

3. Basis of certification                          NCC: 2019
Detail the basis for giving the certificate and
                                                   AS/NZS 4600:2018, AS/NZS 1170.1:2002, AS/NZS 1170.2:2011,
the extent to which tests, specifications,         AS/NZS 1170.3:2002, AS 4100:1998, AS 2870:2011 and AS 3600:2018
rules, standards, codes of practice and
other publications, were relied upon.


4. Reference documentation                         Covering letter of certification
                                                   ShedSafe Site Specific Design Criteria Analysis
Clearly identify any relevant documentation,
e.g. numbered structural engineering plans.        TSSC214004 - 2 General Notes
                                                   TSSC214004 - 3 Layout
                                                   TSSC214004 - 4 Specification Sheet
                                                   TSSC214004 - 5 Bracing
                                                   TSSC214004 - 6 Concrete Piers
                                                   TSSC214004 - 7 Slab Dimensions
                                                   TSSC214004 - 8 Connection Details
                                                   TSSC214004 - 9 Flashing Fixing Details
                                                   TSSC214004 - 10 Purlin And Girt


LOCAL GOVERNMENT USE ONLY
Date received                                                                Reference Number/s

Page 3

5. Building certifier reference                   Building certifier reference number
number                                            NA


6. Competent person details                       Name (in full)
A competent person for building work,             John Ronaldson
means a person who is assessed by the
building certifier for the work as competent      Company name (if applicable)                Contact person
to practice in an aspect of the building and
specification design, of the building work
because of the individual�s skill,                Apex Engineering Group PTY LTD              John Ronaldson
experience and qualifications in the aspect.      ACN 632 588 562
The competent person must also be                 Phone no. (business hours)            Mobile no.     Fax no.
registered or licensed under a law applying
in the State to practice the aspect.              +61 7 5657 4456                                         +61 7 5657 8899
If no relevant law requires the individual to
be licensed or registered to be able to give      Email address
the help, the certifier must assess the
individual as having appropriate experience,      [email protected]
qualifications or skills to be able to give the
help.                                             Postal address
If the chief executive issues any guidelines
for assessing a competent person, the             Steelx Building, 3rd Floor, 2 Boston Court
building certifier must use the guidelines        Varsity Lakes, Qld 4227
when assessing the person.                        Licence or registration number (if applicable)
                                                  RPEQ 24223


7. Signature of competent person                  Signature                                        Date
This certificate must be signed by the                                                               24/08/2021
individual assessed by the building certifier
as competent.




The Building Act 1975 is administered by the Department of Housing and public Works