18/07/2006 12:39 87-54748981 GLUE ror ara some wer NATA ACCREDITED LABORATORY 1793 GLOB AL TESTING UNIT 6/3 COMMERCE CT. NOOSAVILLE. PHONEIFAX 0754 740900. nnn THE ONLY NAME IN SOILS @- | pyNAMIC CONE PENETROMETER REPORT 2, CLIENT: N.C Oliver Pty Ltd AUTHORISED BY: J.F & P PROJECT: Proposed Sewer Alignment, DATE TESTED: 30/06/06 128-132 Gympie Terrace, Noosaville. JOB No. 06/0637 BLOWS PER 100mm DEPTHimm) | PNS | DEPTH(mm) | PN3 | DEPTH(mm) PN3 06-100 41 1500- 1600 1 3000- 3100 20 4100-200 2 1600- 1700 41 3100- 3200 9 200- 300 2 1700- 1800 1 3200- 3300 5 300- 400 4 1800- 1900 4 3300- 3400 6. 400-500 5 1900- 2000 1 3400- 3500 _§ 500- 600 5 2000- 2100 2 3500- 3600 3 600- 700 4 2100- 2200 4 3600- 3700 8 700- 800 3 2200- 2300 1 3700- 3800 8 800- 900 4 2300- 2400 4 3800- 3900 8 900- 1000 2 2400- 2500 2 3900- 4000 7 1000- 1100 2 2500- 2600 2 4000-4100 7 1100- 41200 2 2600-2700 2 4100- 4200 13 1200- 1300 2 2700- 2800 2 4200- 4300 1 1300- 1400 3 2800- 2900 2 4300- 4400 10 1400- 1500 2 2900- 3000 5 4400- 4500 13 use iees heey a Th pectinases a REPORT SHALL NOT BB REPRODUCED EXCEPT IN \TED, SUPERSEUIS ALL DA PREVIOUSLY SSUED REPORTS AUTHORISED Som LL Besse DATE TESTED..63GA: