Unmanaged Melaleuca Forest       Scrub edge of covenant area           Fire Control line:                                                           Townhouses Constructed to AS3959:2009                     Do not plant trees such that the outer
                                          closest to control line      concrete path & mown turf                                                   Construction of Buildings in Bushfire Prone               edge of the mature tree is within 5m of
                                       (undstorey) 2-3m as per         used by fire fighters for                                           Areas. Bushfire Attack Levels to be BALFZ for blocks                    any windows or glazing element.
                                              clause 4.1(i)(ii) of     operational activities eg:                                                             B, C & D and BAL 12.5 for Block A.                 Choose species from approved list.
                                covenant document. Remove              direct suppression, back-burning                                                                                                             Do not plant combustible Koala
                                all tree branches overhanging          etc.                                                                                                                                                               Food trees.
                                       edge of fire control line.
                                                                               Non-combustible retaining wall
                                                                               to Eng. Detail.



                                                                                       Courtyard:                               Radiant Heat Shield - 2.0m high
                                                                                       Low flammability plants chosen           colourbond or masonry fence.
                                                                                       from suitable species list. No plants    Colourbond fence to flush with
                                                                                       or mulches against any windows /         ground. All posts non-combustible.
                                                                                       glazing. Outdoor living area surface
                                                                                       concrete as specified. Balance area
          Bdy




                                                                                       irrigated mown grass or
                                                                                       non-combustible surface such as
                                                                                       decorative gravels, pavers, concrete
                                                                                       etc. Plants permitted as selected from
                                                                                       approved list and not against glazing.
                                                                                       Do not plant trees within courtyard.
                                                                                       Avoid plants that overhang rear fence.




                         Bushland                               Fire Control                          Unit Courtyard                                                                          Townhouse & Carport
                                                                    Line


        Bushfire Management - Typical Townhouse Schematic Section                                                                                                        NTS
         Job 111377 December 1 2011, Iss A

Used in these records

About this file

File size
41.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application part 2 Report_Plans - MCU11_0254.pdf · 41.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.