Development Application part 2 Report/Plans - MCU11/0254
Plans and drawings: the text below has words only, no drawings.
Very large file (41.8 MB): may take a few minutes to open.
Original PDF page 39, section 4. The text section number identifies this passage in the reader.
928.35m2
ENVIRONMENTAL COVENANTAL AREA - 193.75m2
HARD LANDSCAPING SOFT LANDSCAPING - 1781.4m2
ALL GLAZING WITHIN 10m FIRE ZONE TO BE IN UNIT BLOCK MAXIMUM HEIGHT UNIT BLOCK A - 556.7m2
(PATH/PATIO/OUTDOOR LIVING)
ACCORDANCE WITH THE REQUIREMENT OF AS 3959 (FROM NATURAL G.L.)
UNIT BLOCK B - 952.8m2 HARD LANDSCAPING - 528.32m2
UNIT BLOCK A - 2 STOREYS 6.975m PRIVATE OPEN SPACE NO SPECIFIC REQUIREMENTS MIN - 25.50m2 (UNIT 22)
METAL FENCING TO BE FLUSH TO TOP OF RETAINING WALL. UNIT BLOCK C - 477.9m2
SO AS TO NOT ALLOW POTENTIAL EMBER TO PASS THROUGH
UNIT BLOCK B - 2 STOREYS 8.260m (Unit 19)
UNIT BLOCK D - 396.4m2
38.62m2 MAX- 60.30m2 (UNIT 26)
UNIT BLOCK C - 2 STOREYS 7.875m AVERAGE - 30.96m2
TOTAL - 2383.8m2 PRIVATE VEHICLE PARKING 1 PRIVATE VEHICLE SPACE 30 PRIVATE VEHICLE SPACES
UNIT BLOCK D - 2 STOREYS 7.130m
PER UNIT (1 SPACE PER UNIT)
THE FOLLOWING ITEMS ARE TO BE VERIFIED BY
BUILDER/CLIENT PRIOR TO COMMENCEMENT.
- CUT & FILL BATTERS INDICATIVE ONLY
LOT DESCRIPTION VISITOR VEHICLE PARKING NOT REQUIRED 11 VISITOR PARKING
LOT: 4 GROSS FLOOR AREA (GFA) CALCULATIONS
N
- PLATFORM/AND OR TOP OF SLAB LEVELS REFUSE STORAGE - GENERAL WASTE STORE 5 x 1100L SKIP BINS
TO BE CONFIRMED ON SITE PLAN: SP222982 UNIT TYPE 01a (END UNITS) UNIT N0.s 01, 07, 08, 7 UNITS GROUND LEVEL GFA - 46.0m2 (per Unit) 5 x 1100L SKIP BINS
- LOCATION OF EASEMENTS 19, 20, 25, 30 FIRST LEVEL GFA - 41.0m2 (per Unit) - RECYCLING STORAGE 3 x 1100 SKIP BINS
- SEWER LINE
AREA: 6189m2 3 x 1100 SKIP BINS
UNIT TYPE 01b (CENTRAL UNITS) UNIT N0.s 02-06, 09-18, 22 UNITS GROUND LEVEL GFA - 45.2m2 (per Unit)
- BUILDING COVENANT SITE REQUIREMENTS PARISH: TEWANTIN 21-24, 27-29 FIRST LEVEL GFA - 40.1m2 (per Unit)
WATER STORAGE 3,000L PER UNIT 3 x 30,000L UNDERGROUND
- DESIGNATED BUILDING ENVELOPES OR 90,000L COMMUNAL CONCRETE WATER TANKS
- SPECIAL HEIGHT RESTRAINTS BY COUNCIL OR DEVELOPER
COUNTY: MARCH UNIT TYPE 02 UNITS N0. 26 1 UNIT GROUND LEVEL GFA - 47.5m2
BIORETENTION DRAIN 110m2 BIORETENTION DRAIN A - 71.59m2
- SITE BEARINGS & DIMENSIONS SITE COV: 38.51%(2383.8m2) FIRST LEVEL GFA - 42.2m2
BIORETENTION DRAIN B - 38.41m2
GFA TO BE 60% (MAX) OF SITE AREA = GFA(MAX) ALLOWED - 3713.4m2 TOTAL GFA ACHIEVED- 2575.3m2 TOTAL - 110.0m2
Client.
Canto Holdings P/L Table of Contents + Site Plan Dwg No. 4073 DEVELOPMENT APPLICATION
Lot 4 Hofmann Drive PRINTED ON: A3
© Pazcot Pty Ltd 2011
NOOSAVILLE Builder. J. & G. KNOWLES & ASSOCIATES (07) 3341 2592 Drawn JTL Scale 1:500 Issue A Sheet 1/28
www.reitsma.com.au P: 07 54916834 PO Box 3515 Caloundra QLD 4551 Pazcot Pty Ltd. ABN 48 010 681 802 Lic. No. 65652.Lic. under QBSA Act 1991 BDAQ Member. Trading as Reitsma and Associates
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 Report/Plans - MCU11/0254Related documentApplication case desk ↗
About this file
- File size
- 41.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.